background image

EARTHSTONE OVENS PRE-ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS – ETL LISTED 

                  12 

 

G

A

S

 B

U

R

N

E

R

W

O

O

D

A

ll

 w

o

o

d

  

fi

re

d

 i

n

 a

 g

a

s/

w

o

o

d

 c

o

m

b

in

a

ti

o

n

 o

v

e

n

 s

h

o

u

ld

b

lo

ca

te

d

 o

n

 t

h

e

 o

p

p

o

si

te

 s

id

o

th

g

a

b

u

r

n

e

r.

  

T

a

k

e

ca

u

ti

o

n

 t

o

 a

v

o

id

 a

sh

e

fr

o

m

 e

n

te

ri

n

g

 t

h

e

 g

a

b

u

r

n

e

ca

v

it

y.

E

S

A

R

T

H

T

O

N

E

W

O

O

D

-F

IR

E

 O

V

E

N

S

 

 
 

 
 

Summary of Contents for 60-PAGW

Page 1: ...MINENT LOCATION FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SER...

Page 2: ...CE ELECTRICAL DIAGRAM IS LOCATED ON THE CONTROL BOX INSTALLATION MUST CONFORM WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL FUEL GAS CODE ANSI Z223 1 THE NATURAL GAS INSTALLATION...

Page 3: ...ALL INSTRUCTIONS CAREFULLY IMPROPER USE OF THIS APPLIANCE MAY RESULT IN A BUILDING FIRE OR PERSONAL INJURY INSTRUCTIONS MUST BE READ AND THOROUGHLY UNDERSTOOD BY ALL OPERATING AND SUPERVISING PERSONNE...

Page 4: ...OPPOSITE SIDE OF THE GAS BURNER SEE DIAGRAM WOOD SHOULD BE USED ONLY FOR FLAVORING AND AESTHETIC VALUE THE MAIN SOURCE OF HEAT SHOULD BE SUPPLIED BY THE GAS BURNER KEEP A PROPER FIRE EXTINGUISHER CLO...

Page 5: ...rewood container closed at all times when not adding or removing firewood Keep container a considerable distance from the oven and far away from sources of heat or ignition DO NOT store matches paper...

Page 6: ...perienced chimney and duct servicing personnel who are qualified in the removal of both creosote and grease from flues and ducts should be contracted to do the inspection and cleaning The inspection a...

Page 7: ...VE BURNER FOR CLEANING FOLLOW THESE STEPS DISCONNECT CABLE FROM SPARK IGNITER UNSCREW FITTING OF GAS SUPPLY LINE WHICH IS NEAREST TO BURNER ASSEMBLY THIS SUPPLY LINE CONNECTS THE GAS VALVE TO BURNER A...

Page 8: ...L COME BACK ON TEMPERATURE READOUT CONTROLS 4 BLACK DIAL KNOB ROTATE CLOCKWISE TO RAISE OR COUNTER CLOCKWISE TO LOWER SET TEMPERATURE 5 RED BUTTON USED SIMULTANEOUSLY WITH BLACK DIAL KNOB TO SET TEMPE...

Page 9: ...S ON OVEN INTERIOR WILL TURN BLACK IF DOOR IS CLOSED WHILE BURNER IS ON A BACK FLASH CAN ALSO OCCUR AFTER TWO HOURS TURN OVEN OFF AND CLOSE OVEN DOOR DO NOT USE ANY CLEANING AGENTS IN THE OVEN SHUTTIN...

Page 10: ...EARTHSTONE OVENS PRE ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS ETL LISTED 10 GAS BURNER CONTROLS...

Page 11: ...the oven may cause negative pressure servicing proper operation If this area is to be covered with a facade it must be of a non combustable material Temperature gauge and On off switch can be extended...

Page 12: ...LATION INSTRUCTIONS ETL LISTED 12 GAS BURNER WOOD All wood fired in a gas wood combination oven should be located on the opposite side of the gas burner Take caution to avoid ashes from entering the g...

Page 13: ...EARTHSTONE OVENS PRE ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS ETL LISTED 13 LOG CONFIGURATION TOP VIEW SIDE VIEW LOG 1 1 LOG HAS A NOTCH TO SUPPORT LOG FROM ROLLING OFF LOWER SUPPORT LOG...

Page 14: ...4 x24 opening needed for combustion air Only one intake should be installed located in the front or back of oven Gas Burner system Air flow Roof False Ceiling Air flow Air flow 24 x24 opening needed f...

Page 15: ...e pressure below where the gas burner is located The air underneath will travel towards the air flow above creating a suction which will force the gas flame downwards To prevent this a non combustable...

Page 16: ...TO INCREASE REMOVE OVEN DOOR OVEN DOOR SHOULD NOT BE CLOSED WHEN OVEN IS FIRED OVEN DOOR CAN BE POSITIONED AT A 45 DEGREE ANGLE TO ALLOW FOR MORE RAPID HEAT UP WITH A 2 SIDED OVEN YOU CAN HAVE ONE DO...

Page 17: ...0 PAGW 4 W C 85 000 btu 110 PAGW 5 W C 110 000 btu 120 PAGW 3 5 W C 130 000 btu 130 PAGW 5 W C 140 000 btu 160 PAGW 4 5 W C 170 000 btu Add 0 5 W C for ovens with rear burner LP Gas Manifold pressure...

Reviews: