Page 5 

Flowmeter Operation and Maintenance 

The flowmeter reads out directly in U.S. Gallons per Minute of water. The following is the way in 
which a flow rate reading is obtained. 

This supersedes the manufacturer’s instructions for flow 

rate readings.

   

To initiate a flow rate reading, depress and release the button on the face of the flow meter. 
A numeric indication will appear in about one minute. However, allow approximately two 
more minutes for the flow meter indication to stabilize before taking a reading. The flow 
meter will turn off automatically after a period of time.  

The flow meter readout is powered by two AAA alkaline batteries.  The only normal maintenance is 
to replace the batteries as required. 

The following is additional flow meter information, provided by the flowmeter manufacturer, GPI.   

 

Summary of Contents for FMK-1872

Page 1: ...tion must be made in accordance with the instructions set forth in this manual and the EarthLinked Commercial Water Heating System Installation Operation and Maintenance Manual Failure to provide installation by an authorized trained installer in a manner consistent with these manuals will void and nullify the limited warranty coverage for the system EarthLinked Technologies shall not be liable fo...

Page 2: ... of the water heating function and 3 indicate when system maintenance is necessary Flowmeter Kit Parts Figure 1 illustrates and lists the flowmeter kit parts In addition to the parts the normal plumbing tools equipment and supplies will be required when working with threaded and sweat types of fittings and pipe Part Number Description 1 90 degree elbow 1 sweat 2 Coupling 1 sweat 3 Downstream tubin...

Page 3: ...tions do not use Teflon tape to seal these joints Carefully tighten the tubing assemblies into the flowmeter body until firmly sealed IMPORTANT Do not over tighten the tubing assemblies into the flowmeter body Too much tightening force could crack the flowmeter body Wipe the excess pipe sealing compound from the joints The flowmeter assembly is now ready to become part of the final piping assembly...

Page 4: ...FM KIT 04 09 Page 3 Figure 2 Multipoise Piping Arrangement Figure 3 Straight Out Piping Arrangement ...

Page 5: ...ompressor unit Be certain that the 5 downstream piping assembly is at the arrow end of the flowmeter assembly IMPORTANT Protect the flowmeter with a cold wet cloth and a flame shield before soldering joints nearest the flowmeter body Also protect the compressor cabinet paint from the torch flame with a flame shield See examples in Figure 4 After soldering the joints for the flowmeter piping assemb...

Page 6: ... release the button on the face of the flow meter A numeric indication will appear in about one minute However allow approximately two more minutes for the flow meter indication to stabilize before taking a reading The flow meter will turn off automatically after a period of time The flow meter readout is powered by two AAA alkaline batteries The only normal maintenance is to replace the batteries...