ISO-FLAMES gas log sets must be installed only in a wood burning fi replace with the minimum fi rebox
dimensions and venting requirements met (see table on this page). This appliance is designed to burn with
yellow fl ames; adequate ventilation is absolutely necessary.
Burner
Model
Minimum Fireplace Size
BTU Rating
Width
Depth
Height
Natural Gas
Propane Gas
Front
Rear
PET-24(N, P)
30"
24"
16"
18"
50k
50k
PET-30(N, P)
36"
30"
16"
18"
65k
65k
SPECIFICATIONS
DAMPER CLAMP INSTRUCTIONS
The damper clamp with hex bolt (
Fig. 6-2
) is provided as a means to prevent
full closure of the damper blade. The clamp is easily attached to most
damper blades with pliers or a wrench, and must be permanently installed.
The clamp is designed to prevent accidental closure of the damper when
installed as illustrated (
Fig. 6-3 and Fig. 6-4
). Should the clamp not fi t, or
fail to provide the permanent vent opening listed in the table found above,
have a permanent stop installed, remove the
damper blade, or have the damper cut to provide
the minimum permanent opening required.
Note:
These are minimum damper opening
specifications. The damper must be
completely opened when operating
this gas appliance to achieve the best
ventilation possible.
Fig. 6-2
Damper clamp
Set screw
Note
: The minimum chimney height from hearth to top of chimney is 15'.
Minimum permanent free opening area of chimney damper for venting
For factory-built fi replaces
For masonry-built fi replaces
Chimney
height
24"
30"
24"
30"
15'
32 sq. in.
41 sq. in.
36 sq. in.
45 sq. in.
20'
29 sq. in.
37 sq. in.
33 sq. in.
41 sq. in.
25'
28 sq. in.
35 sq. in.
32 sq. in.
39 sq. in.
30'
26 sq. in.
33 sq. in.
30 sq. in.
37 sq. in.
Fig. 6-3
Fig. 6-4
Open
Closed
PILOT
WIRE HARNESS
VALVE
OUTLET
ORANGE
BLUE
GREEN
INLET
AA-BATTERIIES (4)
BATTERY BOX
BATTERY-D
REMOTE
SYSTEM
CONTROL
MODULE
S
WIRE HARNESS
WIRES, OPTIONAL
WALL SWITCH
Wiring Diagram
Fig. 6-1
Note
: Rear width is at corresponding depth.