ISO-FLAMES gas log sets must be installed only in a wood burning fi replace with the minimum fi rebox 
dimensions and venting requirements met (see table on this page). This appliance is designed to burn with 
yellow fl ames; adequate ventilation is absolutely necessary.

Burner

Model

Minimum Fireplace Size

BTU Rating

Width

Depth

Height

Natural Gas

Propane Gas

Front

Rear

PET-24(N, P)

30" 

24"

16"

18"

50k

50k

PET-30(N, P)

36"

30"

16"

18"

65k

65k

SPECIFICATIONS

DAMPER CLAMP INSTRUCTIONS

The damper clamp with hex bolt (

Fig. 6-2

) is provided as a means to prevent 

full closure of the damper blade. The clamp is easily attached to most 
damper blades with pliers or a wrench, and must be permanently installed. 
The clamp is designed to prevent accidental closure of the damper when 
installed as illustrated (

Fig. 6-3 and Fig. 6-4

). Should the clamp not fi t, or 

fail to provide the permanent vent opening listed in the table found above, 
have a permanent stop installed, remove the 
damper blade, or have the damper cut to provide 
the minimum permanent opening required.

Note:

  These are minimum damper opening 

specifications. The damper must be 
completely opened when operating 
this gas appliance to achieve the best 
ventilation possible.

Fig. 6-2

Damper clamp

Set screw

Note

:  The minimum chimney height from hearth to top of chimney is 15'.

Minimum permanent free opening area of chimney damper for venting

For factory-built fi replaces

For masonry-built fi replaces

Chimney 

height

24"

30"

24"

30"

15'

32 sq. in.

41 sq. in.

36 sq. in.

45 sq. in.

20'

29 sq. in.

37 sq. in.

33 sq. in.

41 sq. in.

25'

28 sq. in.

35 sq. in.

32 sq. in.

39 sq. in.

30'

26 sq. in.

33 sq. in.

30 sq. in.

37 sq. in.

Fig. 6-3

Fig. 6-4

Open

Closed

PILOT

WIRE HARNESS

VALVE

OUTLET

ORANGE

BLUE

GREEN

INLET

AA-BATTERIIES (4)

BATTERY BOX

BATTERY-D

REMOTE 

SYSTEM

CONTROL

MODULE

S

WIRE HARNESS

WIRES, OPTIONAL

WALL SWITCH

Wiring Diagram

Fig. 6-1

Note

:  Rear width is at corresponding depth.

Summary of Contents for PET-24N

Page 1: ...e burned in a fireplace where a decorative appliance is installed FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES IMPORTANT READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OF THE LOG SET STADIUM BURNER SET OWNER S MANUAL Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Open a window Do not...

Page 2: ...des pertes humaines Note des Plein carburants ne seront pas brûlés dans une cheminée où un appareil décoratif est installé POUR L INSTALLATION EN CHEMINÉES BRÛLANTES DE COMBUSTIBLE SOLIDE MANUEL DU PROPRIÉTAIRE Ne stockez pas ou n employez pas l essence ou d autres vapeurs et liquides inflammables à proximité de ceci ou d aucun autre appareil CE QUI À FAIRE SIVOUS SENTEZ LE GAZ Ouvrez une fenêtre ...

Page 3: ...CATIONS 6 DAMPER CLAMP INSTRUCTIONS 6 BURNER PARTS LIST 7 BURNER INSTALLATION 8 GLOWING EMBER LAVA COAL PLACEMENT 9 LOG PARTS LIST 9 LOG PLACEMENT 10 INSTALLING REPLACING BATTERIES 11 LIGHTING INSTRUCTIONS 13 CLEANING AND SERVICING 14 FLAME DESCRIPTION 14 TROUBLESHOOTING 15 CUSTOMER SERVICE WARRANTY 17 WARRANTY CARD 18 ...

Page 4: ... intérieur minimum Si la ligne de gaz est plus longue que 20 une ligne de plus grand diamètre peut être nécessaire J Les estimations d entrée montrées en Btu par heure sont pour des altitudes jusqu à 2 000 pi Pour des altitudes au dessus de 2 000 pi référez vous au code national de gaz de carburant ou entrez en contact avec le fabricant avant d installer ce produit K Cet appareil à gaz et son clap...

Page 5: ...Gas supply pipe must be 1 2 minimum interior diameter If the gas line is longer than 20 a larger diameter line may be necessary J Input ratings shown in BTU per hour are for elevations up to 2 000 ft For elevations above 2 000 ft refer to the National Fuel Gas Code or contact manufacturer before installing this product K This gas appliance and its main gas valve must be disconnected from the gas s...

Page 6: ...il to provide the permanent vent opening listed in the table found above have a permanent stop installed remove the damper blade or have the damper cut to provide the minimum permanent opening required Note These are minimum damper opening specifications The damper must be completely opened when operating this gas appliance to achieve the best ventilation possible Fig 6 2 Damper clamp Set screw No...

Page 7: ...ly 3 Remote receiver box 4 Remote transmitter 5 Control valve 4 1 Replacement parts can be ordered from your local Earthcore dealer ITEM NO DESCRIPTION 6 Flex connector 7 Control module 8 Lava coals 9 Damper clamp 10 Elbow 1 2 male flare x 1 2 NPT 24 Model Shown 8 9 Bottom view Heat sensor Pilot Electrode 2 3 5 7 10 6 ...

Page 8: ...as supply stub inside the fireplace and remove the cap if attached see Fig 8 1 4 Use pipe compound resistant to all gases or Teflon tape to attach the supplied elbow to the gas supply stub Then attach the flex connector coming off of the burner system to the elbow see Fig 8 1 5 LEAK TEST Turn on the fireplace gas supply and test at all connections for leaks using the appropriate soapy water soluti...

Page 9: ...e unsafe operation LAVA COALS DECORATIVE Spread the supplied lava coals see BURNER PARTS LIST on the floor of the fireplace around the front and sides of the burner system The lava coals may be placed around and on top of the remote receiver box Leave the front of the box clear for control access Note DO NOT place any lava coals on the burner system or behind it GLOWING EMBER LAVA COAL PLACEMENT N...

Page 10: ...red here to aid in the log placement procedure 1 Prior to log placement be sure the glowing embers were placed as discussed in the GLOWING EMBER PLACEMENT section 2 Set the bottom rear log 1 at the rear of the grate Fig 10 1 Center the log with its back up against the burner tabs 3 Set the bottom left and right logs 2 3 at the front of the burner with the charred ends facing inward Leave a small g...

Page 11: ... BOX BATTERIES To access the batteries locate the remote receiver box and turn it over The exposed D battery pack is for electronic ignition Replace the old batteries with 2 new D batteries See Fig 11 1 Slide open the lid on the remote receiver to expose the batteries Replace the old batteries with 4 new AA batteries See Fig 11 1 Replace the lid When battery replacement is complete properly place ...

Page 12: ...mée et écurie Après une brève durée le pilote allumera alors le brûleur principal ATTENTION SI LE BRÛLEUR NE MET PAS À FEU À MOINS DE 20 SECOUNDS ARRÊTEZ L ATTENTE 5 MINUTES ALORS RÉPÉTEZ LES ÉTAPES 1 À 3 CI DESSUS Normalement lepilotedevraitresterLit S ilsort répétezl étape2ou3 Si le pilote ne restera pas allumé après que plusieurs essais tournent le récepteur à AU LOIN et contactent un fournisse...

Page 13: ...table after a short time the pilot will then light the main burner CAUTION IF THE BURNER DOES NOT IGNITE WITHIN 20 SECONDS STOP WAIT 5 MINUTES THEN REPEAT STEPS 1 THRU 3 ABOVE Normally the pilot should remain lit If it goes out repeat step 2 or 3 If the pilot will not stay lit after several tries turn the receiver to OFF and contact a qualified professional service technician or gas supplier In ad...

Page 14: ...uctions In addition a periodic examination and cleaning of the solid fuel burning fireplace venting system should be conducted by a qualified professional service technician Any safety screen or guard removed for servicing must be replaced prior to operating this appliance TO CLEAN THE LOG SET 1 Remove the log set and embers Use a vacuum cleaner to remove loose particles from all surfaces of the l...

Page 15: ...sparking when activated Note You may need to turn or press ignitor several times to ignite pilot See LIGHTING INSTRUCTIONS for your control valve C Ignitor electrode wire loose C Check wiring and reconnect any loose wiring D Gas supply off manual shutoff valve closed D Turn on gas supply or open manual shutoff valve E Air in gas line E Bleed the gas supply line and repeat LIGHTING INSTRUCTIONS unt...

Page 16: ...he burner system immediately and completely including pilot following the steps in the LIGHTING INSTRUCTIONS section Then call your dealer F Adding any accessories to log sets F Shut down log set and take off any logs or accessories that do not belong with the set PILOT WILL NOT STAY LIT A Valve won t hold A Contact your dealer for instructions on replacement B Pilot hood not aimed at thermocouple...

Page 17: ...s directly at 800 642 2920 It is important for you to register your ISO FLAMES gas log system with Earthcore Please complete the warranty card included in this manual on the following page 1 The ISO FLAMES gas log burner has a one year warranty against any performance defects 2 The ISO FLAMES gas logs have a one year warranty against breakage except breakage due to mishandling or negligence 3 If t...

Page 18: ...__________________________________________________________________ Gas Log Burner Size 24 30 Circle One Gas Control Valve Type remote control safety pilot Gas Type Natural Gas or Liquid Propane LP Circle One Comments Purchased from Name _______________________________________________________________________ City State ____________________________________________________________________ PhoneNumber...

Reviews: