EarthCore PET-24N Owner'S Manual Download Page 5

5

IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION

A.

  This appliance is designed as an

 attended appliance. 

Adults must be present when this gas appliance is operating. 

Do not leave this unit burning when unattended or while anyone is sleeping.

B.

  This appliance is only for use with the type of gas indicated on the rating plate. This appliance is 

NOT FIELD 

CONVERTIBLE

 for use with other gasses.

C.

 

BE CAREFUL: If not installed, serviced, and used correctly per these instructions, this product can cause 

serious personal injury, property damage, or loss of life.

D.

 

WARNING: 

Before installing in a solid-fuel-burning fi replace, 

the chimney fl ue, damper, and fi rebox must be 

thoroughly CLEANED 

of soot, creosote, ashes, and loose paint, and must be inspected by a qualifi ed chimney 

cleaner. Some older fi replaces may need repair prior to installing this appliance. 

E.

  CHECK GAS TYPE (natural or propane): The gas supply must be the same as stated on your burner system rating 

plate. If gas supply is different, 

DO NOT INSTALL

. Contact your dealer for immediate assistance.

F.

  Keep the area of the gas log set clear and free from combustible materials, gasoline, and other fl ammable vapors and 

liquids.

G.

  INSUFFICIENT GAS PRESSURE WILL KEEP THE PILOT FROM OPERATING PROPERLY. DO NOT USE IF GAS 

PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT. 

H.

 The 

minimum

 inlet gas-supply pressure for purposes of input adjustment is 

5"

 water column (w.c.) on 

natural gas

 

and 

11"

 w.c. on 

propane gas

. Insuffi cient gas pressure will affect proper operation of the pilot. Do not install this gas 

appliance if minimum pressure is not available. The 

maximum

 inlet gas-supply pressure is 

10.5"

 w.c. on natural gas 

and 

13"

 w.c. on propane gas. The propane source must be regulated. (Do not connect this appliance directly to an 

unregulated propane gas tank - this can cause an explosion.)

I.

  The gas piping system must be sized to provide minimum inlet pressure at the maximum fl ow rate (BTU/hr). Undue 

pressure loss will occur if the pipe is too small, or the run is too long. Gas supply pipe must be 

1

/

2

" minimum interior 

diameter. If the gas line is longer than 20', a larger diameter line may be necessary.

J.

  Input ratings shown in BTU per hour are for elevations up to 2,000 ft. For elevations above 2,000 ft., refer to the National 

Fuel Gas Code or contact manufacturer before installing this product.

K. 

This gas appliance and its main gas valve must be disconnected from the gas-supply piping system during any pressure 

testing of that system at test pressures in excess of 

1

/

2

 psig.

L. 

This gas appliance must be isolated from the gas-supply piping system by closing the equipment shutoff valve connected 

to the gas-supply line during any pressure testing of the gas-supply piping system at test pressures equal to or less 
than 

1

/

2

 psig.

M. 

Do not use this appliance if any part has been underwater. Immediately call a qualifi ed service technician to inspect the 

appliance and to replace any part of the control system and any gas control that has been underwater.

N. A fi replace screen must be in place when the log set is burning.

 Provisions for adequate combustion air must be 

maintained. Unless other provisions for combustion air are provided, the screen shall have an opening(s) for introduction 
of combustion air. Combustion air is adequate when all fl ames curl into the fi replace and away from the screen. 

When 

glass fi replace doors are used, operate the gas log set with the doors fully open.

O. 

This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited 

by local codes. Installation of appliances designed for manufactured home (U.S. only) or mobile home installation must 
conform with the Standard 

CAN/CSA Z240 MH

Mobile Housing

, in Canada, or with the 

Manufactured Home Construction 

and Safety Standard, Title 24 CFR, Part 3280,

 in the United States, or when such a standard is not applicable, 

ANSI/

NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.

CAUTION:  Installation and repair must be done by an NFI Certifi ed or other qualifi ed professional 

installer. 

Installer: 

Carefully read these instructions before installing this gas burner system.  Be sure you understand 

all safety precautions and warnings contained in this manual.

Summary of Contents for PET-24N

Page 1: ...e burned in a fireplace where a decorative appliance is installed FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES IMPORTANT READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OF THE LOG SET STADIUM BURNER SET OWNER S MANUAL Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Open a window Do not...

Page 2: ...des pertes humaines Note des Plein carburants ne seront pas brûlés dans une cheminée où un appareil décoratif est installé POUR L INSTALLATION EN CHEMINÉES BRÛLANTES DE COMBUSTIBLE SOLIDE MANUEL DU PROPRIÉTAIRE Ne stockez pas ou n employez pas l essence ou d autres vapeurs et liquides inflammables à proximité de ceci ou d aucun autre appareil CE QUI À FAIRE SIVOUS SENTEZ LE GAZ Ouvrez une fenêtre ...

Page 3: ...CATIONS 6 DAMPER CLAMP INSTRUCTIONS 6 BURNER PARTS LIST 7 BURNER INSTALLATION 8 GLOWING EMBER LAVA COAL PLACEMENT 9 LOG PARTS LIST 9 LOG PLACEMENT 10 INSTALLING REPLACING BATTERIES 11 LIGHTING INSTRUCTIONS 13 CLEANING AND SERVICING 14 FLAME DESCRIPTION 14 TROUBLESHOOTING 15 CUSTOMER SERVICE WARRANTY 17 WARRANTY CARD 18 ...

Page 4: ... intérieur minimum Si la ligne de gaz est plus longue que 20 une ligne de plus grand diamètre peut être nécessaire J Les estimations d entrée montrées en Btu par heure sont pour des altitudes jusqu à 2 000 pi Pour des altitudes au dessus de 2 000 pi référez vous au code national de gaz de carburant ou entrez en contact avec le fabricant avant d installer ce produit K Cet appareil à gaz et son clap...

Page 5: ...Gas supply pipe must be 1 2 minimum interior diameter If the gas line is longer than 20 a larger diameter line may be necessary J Input ratings shown in BTU per hour are for elevations up to 2 000 ft For elevations above 2 000 ft refer to the National Fuel Gas Code or contact manufacturer before installing this product K This gas appliance and its main gas valve must be disconnected from the gas s...

Page 6: ...il to provide the permanent vent opening listed in the table found above have a permanent stop installed remove the damper blade or have the damper cut to provide the minimum permanent opening required Note These are minimum damper opening specifications The damper must be completely opened when operating this gas appliance to achieve the best ventilation possible Fig 6 2 Damper clamp Set screw No...

Page 7: ...ly 3 Remote receiver box 4 Remote transmitter 5 Control valve 4 1 Replacement parts can be ordered from your local Earthcore dealer ITEM NO DESCRIPTION 6 Flex connector 7 Control module 8 Lava coals 9 Damper clamp 10 Elbow 1 2 male flare x 1 2 NPT 24 Model Shown 8 9 Bottom view Heat sensor Pilot Electrode 2 3 5 7 10 6 ...

Page 8: ...as supply stub inside the fireplace and remove the cap if attached see Fig 8 1 4 Use pipe compound resistant to all gases or Teflon tape to attach the supplied elbow to the gas supply stub Then attach the flex connector coming off of the burner system to the elbow see Fig 8 1 5 LEAK TEST Turn on the fireplace gas supply and test at all connections for leaks using the appropriate soapy water soluti...

Page 9: ...e unsafe operation LAVA COALS DECORATIVE Spread the supplied lava coals see BURNER PARTS LIST on the floor of the fireplace around the front and sides of the burner system The lava coals may be placed around and on top of the remote receiver box Leave the front of the box clear for control access Note DO NOT place any lava coals on the burner system or behind it GLOWING EMBER LAVA COAL PLACEMENT N...

Page 10: ...red here to aid in the log placement procedure 1 Prior to log placement be sure the glowing embers were placed as discussed in the GLOWING EMBER PLACEMENT section 2 Set the bottom rear log 1 at the rear of the grate Fig 10 1 Center the log with its back up against the burner tabs 3 Set the bottom left and right logs 2 3 at the front of the burner with the charred ends facing inward Leave a small g...

Page 11: ... BOX BATTERIES To access the batteries locate the remote receiver box and turn it over The exposed D battery pack is for electronic ignition Replace the old batteries with 2 new D batteries See Fig 11 1 Slide open the lid on the remote receiver to expose the batteries Replace the old batteries with 4 new AA batteries See Fig 11 1 Replace the lid When battery replacement is complete properly place ...

Page 12: ...mée et écurie Après une brève durée le pilote allumera alors le brûleur principal ATTENTION SI LE BRÛLEUR NE MET PAS À FEU À MOINS DE 20 SECOUNDS ARRÊTEZ L ATTENTE 5 MINUTES ALORS RÉPÉTEZ LES ÉTAPES 1 À 3 CI DESSUS Normalement lepilotedevraitresterLit S ilsort répétezl étape2ou3 Si le pilote ne restera pas allumé après que plusieurs essais tournent le récepteur à AU LOIN et contactent un fournisse...

Page 13: ...table after a short time the pilot will then light the main burner CAUTION IF THE BURNER DOES NOT IGNITE WITHIN 20 SECONDS STOP WAIT 5 MINUTES THEN REPEAT STEPS 1 THRU 3 ABOVE Normally the pilot should remain lit If it goes out repeat step 2 or 3 If the pilot will not stay lit after several tries turn the receiver to OFF and contact a qualified professional service technician or gas supplier In ad...

Page 14: ...uctions In addition a periodic examination and cleaning of the solid fuel burning fireplace venting system should be conducted by a qualified professional service technician Any safety screen or guard removed for servicing must be replaced prior to operating this appliance TO CLEAN THE LOG SET 1 Remove the log set and embers Use a vacuum cleaner to remove loose particles from all surfaces of the l...

Page 15: ...sparking when activated Note You may need to turn or press ignitor several times to ignite pilot See LIGHTING INSTRUCTIONS for your control valve C Ignitor electrode wire loose C Check wiring and reconnect any loose wiring D Gas supply off manual shutoff valve closed D Turn on gas supply or open manual shutoff valve E Air in gas line E Bleed the gas supply line and repeat LIGHTING INSTRUCTIONS unt...

Page 16: ...he burner system immediately and completely including pilot following the steps in the LIGHTING INSTRUCTIONS section Then call your dealer F Adding any accessories to log sets F Shut down log set and take off any logs or accessories that do not belong with the set PILOT WILL NOT STAY LIT A Valve won t hold A Contact your dealer for instructions on replacement B Pilot hood not aimed at thermocouple...

Page 17: ...s directly at 800 642 2920 It is important for you to register your ISO FLAMES gas log system with Earthcore Please complete the warranty card included in this manual on the following page 1 The ISO FLAMES gas log burner has a one year warranty against any performance defects 2 The ISO FLAMES gas logs have a one year warranty against breakage except breakage due to mishandling or negligence 3 If t...

Page 18: ...__________________________________________________________________ Gas Log Burner Size 24 30 Circle One Gas Control Valve Type remote control safety pilot Gas Type Natural Gas or Liquid Propane LP Circle One Comments Purchased from Name _______________________________________________________________________ City State ____________________________________________________________________ PhoneNumber...

Reviews: