63
Burner Lighting Instructions
INSTALLER INSTRUCTIONS
It is required that the set of safety instruction labels that have been supplied with the appliance be affixed to the
operation and control points of the appliance. It is the installers responsibility to ensure these warnings are properly
affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this
appliance
.
PRE-LIGHTING CHECKLIST
Be sure to check these items before the initial lighting of the appliance:
•
Gas pressure has been checked carefully
•
All gas fittings have been checked for leaks.
•
All clearances to combustibles have been met
•
All combustibles materials have been removed from
the area in front of the appliance.
•
All vented areas of the appliance face are
unobstructed.
•
House is ventilated to clear initial paint curing odors
•
All packaging materials have been removed from the
appliance.
•
While appliance is cool, fingerprints or other marks
have been cleaned from any plated surfaces with
denatured alcohol and a soft cloth. Marks left on these
surfaces may become permanent into the finish if not
removed prior burning the unit.
WARNING!!!:
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
SAFETY INSTRUCTIONS
A.
This appliance is equipped with an ignition device which automatically lights the pilot. Do NOT try to light the
pilot by hand.
B.
BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
:
•
Do not try to light any appliance.
•
Do not touch any electric switch; do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•
If you cannot reach your gas supplier, call the fire department.
C.
If any portion of this appliance does not operate as the instructions indicate, do not try to repair it, call a
qualified service technician. Do not use tools. Force or attempted repair may result in a fire or explosion.
D.
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician
to inspect the appliance and to replace any part of the system and any gas control which has been under
water.
Main Power Switch, Battery Holder Switch Pack, and Remote Overview
The ADC100 and the control module must have 120 VAC. The remote will not operate the appliance if power is
not supplied to ADC100 and control module. When wired correctly, the remote will initiate the fan and damper
operation when the
“ON/OFF
” key is pressed. Once draft is proven, the ADC100 will allow the burner pilot to
spark. Once pilot is ignited the main burner will turn on.
TO TURN OFF GAS TO APPLIANCE
1)
Turn the main power switch in the “OFF” position
2)
Turn off all electric power to the appliance if service is to be performed.
3)
Close the main line gas shut-off valve.
WARNING!!!: OPERATION OF THIS APPLIANCE WHEN NOT CONNECTED TO A PROPERLY INSTALLED
AND MAINTAINED VENTING SYSTEM CAN RESULT IN CARBON MONOXIDE (CO) POISONING AND
POSSIBLE DEATH.