Earthcore Industries
02/2021
Isokern Maximus Linear Series See-Thru Gas Fireplace
43
Enervex ADC 100 INSTALLATION
5.
The probe must be installed between the
appliance and the exhaust fan. If a damper is
used in the system, the probe should be
installed between the appliance and damper.
The probe needs to be at least 3’ from the
last elbow in the vent run.
6.
For fireplace installations, the probe should
be installed close to the fan inlet
. See Figure
43.
7.
To produce an accurate pressure reading, the
probe should be installed flush with the inner
wall of the chimney or stack. If double walled
stack is used, the probe should be flush with
the inner most wall.
Fan Speed Control
8.
Locate the FSC in close proximity to the
burner valve control system but only in a
location accessible to service technician.
Connect the FSC control switch as shown in
Figure 44
.
The FSC will be utilized for the initialization
set up, see
page 64
NOTE:
After the installation is complete, perform a functional check.
FIGURE 43
FIGURE 44