Firebrick Installation - Maximus Linear Fireplace
1.
Starting approximately 1/2” from the rear of the firebox,
FIGURE 48,
lay one course of “full” sized firebrick on floor. Ensure a
gap of approximately 1/2” is kept between firebrick and sidewall to
allow for expansion.
2.
Lay two courses of “full” sized firebrick so that the leading edge of
the coursing is aligned with opening of the firebox. Ensure a gap of
approximately ½” is kept between firebrick and sidewall to allow
for expansion.
3.
Apply “split” firebrick to the rear wall of the unit. Ensure
approximately 1/2” gap is kept between firebrick and sidewall, as
well as an 1/4” gap is kept between firebrick and damper beam
assembly to allow for expansion.
4.
Starting at the front edge of the unit’s sidewall, apply “split”
firebrick to the side wall of the unit. Ensure approximately ¼” gap
is kept between firebrick and damper beam/damper block
assembly to allow for expansion.
5.
Repeat on opposite side wall.
IMPORTANT:
Ensure that the required holes for the Isoflames Linear burner’s 3/8”
gas supply line and pilot assembly gas and electrical connections are
drilled prior to firebrick installation.
DO NOT COVER THESE AREAS
WITH FIREBRICK!
FIGURE 48
FIGURE 49