EarthCore Isokern Magnum 86072 Series Installation, Operation, Maintenance And Owner'S Manual Download Page 4

              

  Intended Use Statement

Note: Do not scale drawings. Illustrations in this manual are 

not to scale and are intended to show “typical” installations.

 

Nominal dimensions are given for design and 

framing reference only, since actual installations may vary 

due to job specific design preferences. Always maintain the 

stated minimum clearances to combustible materials. Do not 

violate any specific installation requirements.

 

The EPA Phase 2 qualified Standard Series fireplace 

and DM 54 chimney system is tested and listed by Warnock 

Hersey (Intertek Testing Service) - Report No. 315965MID-

008 and Report No.315986MID-006 - to UL 127, and UL 

103HT  -  2006.  The  EPA  qualifying  emissions  tests  were 

conducted by OMNI-Test Laboratories Report No.: 257-F-

06-3.

 

EPA  Phase  2  qualified  Standard  Series  fireplace 

systems are also designed for installation in accordance 

with  the  National  Fire  Protection  Association  Standard 

for  chimneys,  fireplaces,  vents  and  Solid  Fuel-Burning 

Appliances (NFPA 211). 

EPA  Phase  2  qualified  Standard  Series  fireplaces  are  not 
listed for use with fireplace inserts.

4

Intended Product Use Statement:

 

The  EPA  Phase  2  qualified  Standard  Series  fireplace 

and DM 54 chimney systems are intended to burn solid wood 

fuel, propane or natural gas. 

Note:

 

Installation of a gas pipe must comply with the 

Standard  for  Decorative  Gas  Appliances  for  Installation  in 

Vented Fireplaces, ANSI Z21.60.

 

This  fireplace  is  not  designed  to  sit  directly  on  a 

combustible floor system. The Fire-Lite application is designed 

to sit on a combustible floor.  

This  fireplace  is  intended 

for use as a supplemental heat source only and is not intended 

for heavy use as a primary heating system.

 

Overfiring, abusive burning or mistreatment will void 

any claims (eg. burning construction debris or other highly 

flammable material; tossing, kicking or otherwise forcing logs 

into the firebox).

 

EPA  Phase  2  qualified  Standard  Series  fireplace  and 

DM  54  chimney  systems  are  conventional  indoor  or  outdoor 

fireplaces designed to appear like traditional masonry fireplaces. 

EPA  Phase  2  qualified  Standard  Series  fireplace  and  DM  54 

chimney system units are intended for installation in residential 

homes and other buildings of conventional construction.

Note:  The local authority having code jurisdiction should be 

consulted before installation to determine the need to obtain a 

permit.

 

Important areas of concern with the installation of

these  fireplaces  are:  construction  of  proper  load  bearing 

foundation  and  concrete  support  slab;  code  required  hearth 

extension  substrates  and  supports;  proper  assembly  of 

components;  clearance  to  combustible  materials;  height  of 

chimney;  and,  techniques  employed  in  applying  finishing 

materials to the fireplace opening and hearth extension.

 

Each of these important topics will be covered in detail 

throughout this manual. Installation personnel must give special 

attention to each topic as the installation progresses.

 

All work performed on, near and adjoining the fireplace 

and chimney installation must meet or exceed the specifications 

and requirements in this manual and the prevailing local building 

code.

 

Subsequent  renovations,  additions  of  cabinets  and 

storage spaces in the enclosure surrounding the fireplace are also 

limited to the specifications in this manual and to the prevailing 

local building code.

 

Isokern is not responsible for other construction work 

around the fireplace unit.

WARNING:

 

This  fireplace  has  not  been  tested  for  use  with  glass 

doors. To reduce the risk of fire or injury, do not install glass 

doors.

 

Some  jursdictions  require  the  use  of  glass  doors.  If 

glass doors are used, operate fireplace with doors in the fully 

open position.

 

Summary of Contents for Isokern Magnum 86072 Series

Page 1: ...g manufacturer s explicit installation sizing and operation instructions It is the responsibility of the general contractor to provide adequate clearances from all firebox surfaces as specified in thi...

Page 2: ...List and Dimensions Isokern Standard Series Component List and DImensions Magnum Series Component List and Dimensions Magnum 86072 Series Required Clearance to Combustibles Assembly Instructions Isok...

Page 3: ...consists of an outer casing block and an inner liner with a fourteen inch 14 diameter flue hole The chimney components are field assembled using Earthcore Mortar to glue the components together The D...

Page 4: ...s eg burning construction debris or other highly flammable material tossing kicking or otherwise forcing logs into the firebox EPA Phase 2 qualified Standard Series fireplace and DM 54 chimney systems...

Page 5: ...of air during the normal firing process In the event the home is tightly sealed and has modern energy efficient features the optional combustion air supply kits may not provide all the air required to...

Page 6: ...Warnock Hersey Listing Label Facsimile 6...

Page 7: ...n a permit EPA Yellow Phase 2 Qualifying Hangtag 7 MANUFACTURER EARTHCORE INDUSTRIES LLC MODEL NO Series 36 C PARTICLE EMISSIONS 2 93 GRAMS KG OF WOOD BURNED For proper operation catalyst must be repl...

Page 8: ...4 C 5 2 3 4 G 69 3 4 69 3 4 37 1 4 69 3 4 WEIGHT 1300 lbs 1420 lbs 1600 lbs 3 10 3 4 Catalyst 56 W x 71 H x 29 1 2 D MINIMUM FRAMING 46 W x 71 H x 29 1 2 D 52 W x 71 H x 29 1 2 D C 33 43 33 48 36 42...

Page 9: ...ually seen coming out of a chimney is essentially a combination of unburned fuel carbon and hydrogen and moisture in the form of water vapor The Catalytic Combustor system is a technology that provide...

Page 10: ...Model A 36 43 Smoke Dome Small Part No Model Qty No 12 36 2 Smoke Dome Medium Part No Model Qty No 11 46 2 Side Wall Part No Model Qty No 20 36 6 Back Walls Part No Model Qty No 25 36 3 Model A 36 26...

Page 11: ...48 Qty 2 2 2 SMOKE DOME 12 28 2 Size A 32 1 2 43 43 53 True Height When Installed 34 28 2 90 28 6 9 G 5 1 2 Model 28 Only 65 28 3 G Cut to 20 Cut as shown mortar pieces together and stagger joints wh...

Page 12: ...ze 34 60 4 34 72 4 Backwall Part Fireplace Quantity No Size M67 60 8 M67 72 8 Damper Support Left and Right Part Fireplace Quantity No Size M94L 60 M94L 72 1 1 M94R 60 1 M94R 72 1 43 28 6 1 4 6 1 4 52...

Page 13: ...above the top of the firebox opening Drywall must be cut 2 back from the firebox opening sides and 8 above the top of the opening Notes A The EPA Phase 2 qualified Standard Series fireplace fireplace...

Page 14: ...ly mortared firebox and smoke dome assembly requires approximately 25 pounds dry measure of Earthcore mortar Broken Components Components broken into 2 or 3 pieces can be repaired by using Earthcore m...

Page 15: ...one half inches 1 1 2 above the top of the concrete support slab If the design preference is for a raised hearth floor of the fireplace elevated above the room s floor then the base plate can be set o...

Page 16: ...firebox for level If necessary adjust the top surface of the box assembly for level by inserting a shim between the lowest wall component and the top surface of the base plate Any gap created under t...

Page 17: ...e smoke dome sloping sidewalls have a beveled bottom edge so that they will sit tight onto the flat top of the side walls Step 12 Make sure that all component contact surfaces have been properly seale...

Page 18: ...Assembly Instructions Isokern Magum 86072 Models 18...

Page 19: ...eat expansion The sleeve passes through the firebox wall and must be connected to metal pipe by other either flexible or rigid that leads to the source for outside combustion air as directly as possib...

Page 20: ...inished brickwork however this is just a suggestion and other face joint dimensions are also acceptable Step 1 Wet mop the inside of the EPAPhase 2 qualified Standard Series fireplace with a damp spon...

Page 21: ...3 8 in the brick work is recommended and has the best appearance Other face joint dimensions are acceptable however smaller joints may not leave room for heat expansion of fire brick 3 Start the fire...

Page 22: ...econd fire should be the same as the first fire The second fire should burn for no more than thirty to sixty minutes and allowed to go out Do not refuel the fireplace during the second lighting A twen...

Page 23: ...ing season in colder climates thoroughly inspect the Fire Lite fireplace and chimney system Chimneys must be installed so that access is provided for inspection and cleaning The chimney should be insp...

Page 24: ...ng directions in manufacturers operating manual For warranty purposes proof of fireplace or HearthCAT purchase is required Labor for removal and or re installation of the catalytic component is not th...

Page 25: ...brief description of the defect ISOKERN or any division thereof is not responsible for any labor costs or indirect costs incurred for the replacement of defective components ISOKERN is not responsibl...

Reviews: