background image

OPERATION

Before starting work it is advisable to test

the work surface for the ideal

temperature to use. The table below

gives an indication of the likely heat

settings required but always start with

the low heat setting. All applications, with

the exception of removing paint from

window frames, can be performed

without using a nozzle, however for best

results nozzles are recommended.

Nozzles

The gun is supplied with 2 different

shaped nozzles, which can be used as

follows.

Concentrator

Nozzle - G84

Directs a

concentrated heat

flow to the work

surface.

Ideal for removing

paint in awkward

corners, crevices,

mouldings,

beading or

architraves.

Glass Protection

Nozzle - G89

Deflects the heat

away from glass

or other fragile

areas.

Ideal for window-

sills, ledges,

frames and

skirting boards.

Removing Paint - General

Do not heat the paint for too long as

this will burn the paint, making it

difficult to remove.

1.Choose the required nozzle and fit

onto the heat outlet.

2.Hold the gun with nozzle approximately

50mm (2”) from surface of paintwork.

3.Starting with the low heat setting, move

the gun slowly backwards and forwards

until the paint blisters and bubbles.

4.Immediately remove the paint with a

scraper or shavehook.

5.Aim to heat the paint just ahead of the

scraper so that you can develop a

continuous action.

Removing Paint from

Window Frames

WARNING – Glass can break easily

when heated.

1.Use the glass protection nozzle.

2.Ensure the nozzle is facing the correct

way to deflect heat away from the

glass before you switch on the heat

gun.

3.Rotate the gun/nozzle 90º as you move

to horizontal or vertical bead (take care

it could be hot!).

4.Paint can be removed by using a

shavehook and/or a soft, wire brush.

Maintenance

Always allow the machine to cool down

(before storing) and disconnect from the

power supply. The heat gun should be

cleaned before being stored away by

wiping over with a clean damp cloth.

DO

NOT USE

CHEMICALS.

Ensure that the ventilation

slots are not blocked.

Trouble Shooting

If a problem occurs always switch off

the unit immediately at the mains.

My Unit fails to work?

Check the fuse in the plug is sound and

rated 13 amps.

If an extension cable is used it must be

fully unwound and rated at least 10

amps capacity.

3

Concentrator Nozzle

Glass

Protection Nozzle

G84

G89

Low

High

Welding Plastic

Paint Stripping

Bending Plastic

Defrosting Pipes

Heat shrinking

plastic

Removes vinyl

floor tiles
Soldering
Lighting BBQʼs

Suggested Ratings

HG1500.qxd:G29 09/05.qxd  22/3/10  16:14  Page 3

All manuals and user guides at all-guides.com

Reviews: