background image

EAPL 

Model

  

EMS-10 V4.0

 

                                                                
 
  

                POWER/ ENERGY  

www.eaplindia.com

 

 

 

DIMENSION 

 

   

FRONT VIEW 

CONNECTIONS                             

REAR VIEW

      

 
 
                                                       

FUNCTION 

 

1.

 

Connect 3 phase 4 wire voltage and 
current circuit as per the diagram 
given in the connection diagram. 

2.

 

Connect rated auxiliary supply at 
terminals 15 and 16 

3.

 

Moment voltage is applied on 
auxiliary terminal, display starts 
showing parameter one by one in auto 
scaling mode.  

Following are the parameters displayed.  

 

 

 
 

PARAMETERS 

R-PF 

Y-PF 

B-PF 

T-PF (TOTAL-PF) 

R-W (Active Power) 

Y-W (Active Power) 

B-W (Active Power) 

T-W (Active Power- TOTAL) 

R-VAr (Reactive Power) 

Y-VAr (Reactive Power) 

B-VAr (Reactive Power) 

T-VAr (Reactive Power-TOTAL) 

R-VA (Apparent Power) 

Y-VA (Apparent Power) 

B-VA (Apparent Power) 

T-VA (Apparent Power-TOTAL) 

Active Energy (KWh) 

Reactive Energy Cap (KVArhC) 

Reactive Energy Ind (KVArhI) 

Apparent Energy (KVAh) 

 Load Hours (LH) 

Old Active Energy (OKWh) 

Old Reactive Energy Cap (OKVrhC) 

Old Reactive Energy Ind (OKVrhI) 

Old Apparent Energy (OKVAh) 

Old Load hours (OL) 

Device ID (Communication Status) 

 
 

 

Parameters can be viewed in SCROLL/HOLD mode 
using SCROLL/HOLD button. 
 

 

Press NEXT/ PREVIOUS to view respective parameter 
in Hold mode 

 

 

Once there is a power failure, Energy, Load Hour and 
Hold/ Scroll status will be saved. 

 

 

Connect terminals 7,8 to the converter using 
communication cables.(details of communication cable 
wiring drawing is shown below).connect a resistor of 
120 ohms at the end of daisy chain as shown in figure. 

 

 

Provide unique Id for devices to identify individual 
units

 

 

Communication status is displayed in Dev ID 
parameter. ‘T’ for Transmit, ‘R’ for Receive & ‘U’ for 
device id mismatch 

 

 

 

 Note

:  All  terminal  to  be  screwed  tightly,  else  the  reading 

may not be accurate. 

 
 
DATA COMMUNICATION CABLE

  

Manufacturer name: BELDEN  
22AWG  (7x30)  stranded  tinned  copper,  dateline  insulated, 
twisted  pairs.  Overall  standard  tinned  copper  drain  wire. 
Overall 90% coverage tinned copper braid shield. Black UV 
resistant PVC jacket. 

 

 

Page 3 of 3 

 

INSTRUCTION MANUAL 

 

1.

 

Top Display 
Window 

2.

 

Bottom Display 
Window 

3.

 

Previous button 

4.

 

Scroll/Hold button 

5.

 

Next button 

6.

 

Select button 

7.

 

Advance button 

 

1, 2, 3, 4

   :  R, Y, B, N 

5 ,6

           : No connection 

7,8

             

:  

A,B (RS 485Communication port)                                                        

9, 10

          :  S1, S2 (R Phase) 

11,12

         :  S1, S2 (Y Phase) 

13,14

        :  S1, S2 (B Phase) 

15,16

         : Auxilary Supply

 

(

85- 270 VAC/ DC

)

 

Accessories: 
 

 

EMS  10  unit  with  button  flap  in 
place. 

 

Panel 

locking 

Clamps 

with 

screws  

 

(Qty: 2 nos each) 

 

Instruction Manual 

DOC NO:

  

OD RE YN 45001 0 Rev NO: 01  Dtd: 16/10/2013 

Page 1 of 3 

   

 