There are default values defined for each object in the K-Matrix. But each value can be
changed by hand. The values can be edited by means of a Prop A config message as
described in chapter 9.5.1.
Example data fields for setting the timing of the fast mode to 20ms LED on after each 50ms:
CAN-ID
DLC Data
Byte 0
Data
Byte 1
Data
Byte 2
Data
Byte 3
Data
Byte 4
Data
Byte 5
Data
Byte 6
Data
Byte 7
0x18EFFF00
8
0x04
0x2B
0x00
0x14
0x00
0x00
0x00
0x00
0x18EFFF00
8
0x04
0x2C
0x00
0x32
0x00
0x00
0x00
0x00
Changes between Software version 04.05.001 and 06.03.000
or newer
During further development it was necessary to implement some changes in the software.
The changes for J1939 communication are shown in the table below:
Type
Index
Change
04.05.001
06.03.000
Object 0x01
NVM group has changed
EOL
EOL
identification
Object 0x05
New NVM groups added (0xA5 =
Load Dump; 0xA6 = EOL
identification)
---
new groups
Object 0x06
New NVM groups added (0xA5 =
Load Dump; 0xA6 = EOL
identification)
---
New groups
Object 0x16
NVM group has changed
EOL
EOL
identification
Object 0x17
NVM group has changed
EOL
EOL
identification
Object 0x1As0
Adjust Undervoltage limit
8000
7000
Object 0x1As3
Adjust hysteresis time
80
500
Object 0x1Ds0-s3 New development object added
---
New Object
Object 0x1Es0-s2 New development object added
---
New Object
Object 0x1Fs0-
s12
New development object added
---
New Object
Error
Codes
---
The error codes were reduced to the
essential groups
---
---
Error
Codes
0x18FECA
(PGN)
Button indices changed
B1 -> 0, B2 -> 2,
B3 -> 4, B4 -> 1,
B5 -> 3, B6 -> 5
B1 -> 0, B2 -> 1,
B3 -> 2, B4 -> 3,
B5 -> 4, B6 -> 5