Single character commands can be sent to the amplifier to achieve the following: 

"1" key enables telemetry (readback similar to LCD display) - this is the default 
mode at power up  

“2” key clears any faults and tries to start the supply. 

“0” key disables telemetry (Complement to “1” key) 

 

Custom commands and display lists can be implemented upon customer 
request. 

 

 

 

Chapter 3 Technical Description  

 
3.1 GENERAL DESCRIPTION 

 
The 2400L is designed to amplify signals by 55 dB in the frequency band of  10 
KHz to 10 MHz. The signal from the front panel N connector is fed via a length of 
50 ohm coaxial cable into the a splitter and the two outputs are fed to the input of 
the driver amplifier modules. The signal from the input of the driver is coupled to 
the input of the MMIC front end. The output signal of the MMIC is coupled to the 
gate of transistor Q1. The further amplified signal appearing at the drain of Q1 is 
coupled  to  the  input  of  Q2.  This  is  transformed  to  50 

  and  fed  to  the  driver 

output BNC port.  
 
The driver output signal is fed through a length of coaxial cable to the input of the 
two  power  splitters,  the  four  outputs  of  this  are  each  fed  to  the  four  amplifier 
modules.  In  each  PA  module  the  signal  is  split  into  two  equal  phase  and 
amplitude signals. These signals are fed to the inputs of  transistors Q1 and Q2. 
The amplified signals appearing at  the drains of Q1 and Q2 are then fed to the 
output BNC port via the impedance matching network. The output of the modules 
is then fed to the combiner to produce a single signal. 
 
The power signal is then fed into a length of 50 ohm coaxial cable to the RF bi-
directional  coupler.  The  output  of  the  coupler  is  then  fed  directly  to  the  N 
connector on the front panel, this is the unit output. 
 
The forward and reverse coupled ports of the bi-directional coupler are fed to the 
RF detector which is situated on the main control board. The RF detector feeds a 
voltage,  which  is  representative  of  the  true  RMS  power  to  the  control  board 
proper. The control board in turn drives the front panel display. 
 

Summary of Contents for 2400L

Page 1: ...out notice August 2012 Revision B 1 2400L Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extreme caution in handling these volt...

Page 2: ...lly operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must be returned to E I freight cos...

Page 3: ...SB pulse and any complex modulation signals The amplifier has 55 dB gain it is unconditionally stable and will not oscillate even with combinations of mismatched source and load impedance It is protec...

Page 4: ...lts RMS for all output load conditions without damage POWER OUTPUT METER True RMS power detection 3 of full scale accuracy POWER REQUIREMENTS 100 240 VAC 47 63 Hz SIZE H x W x D 13 x 16 75 x 20 inches...

Page 5: ...5 times the level of the input signal required to achieve maximum output Input voltages in excess of 2 volts peak may permanently damage the instrument iii Connect the output via a 50 ohm coaxial lead...

Page 6: ...suitable for connection to a PC or host system The communication protocol is extremely simple to facilitate readback and control with readily available terminal programs such as Hyperterm The RS 232...

Page 7: ...further amplified signal appearing at the drain of Q1 is coupled to the input of Q2 This is transformed to 50 and fed to the driver output BNC port The driver output signal is fed through a length of...

Page 8: ...bject to change without notice August 2012 Revision B 8 There are four switch mode power supply units three provide a 42 VDC 24 ampere source The other provides 42VDC and 24 VDC outputs and provides a...

Page 9: ...ail safe under all load conditions Damage can only be externally caused by the incorrect selection of the AC supply voltage or by an input signal in excess of the specified 1 volt rms equivalent to a...

Page 10: ...or c Adjust the output level of the sweep generator so that a 50 ohm video detector connected at the output of the unit will not be damaged by excessive power output Reference section 4 4 1 for set up...

Page 11: ...D151 e Attenuator 30 dB 500 Watts Bird Figure 4 1 Gain Measurement 2 Connect the equipment as shown in Figure 4 1 then proceed as follows a Set the oscilloscope to DC Time cm to Ext X and gain to l0mv...

Page 12: ...full deflection Rotate the step attenuator CCW so that the output is reduced by 50 dB g Reconnect the 2400L into the test set up of Figure 4 1 h Place the 2400L power switch to the ON position i Obser...

Page 13: ...ap the instrument in heavy paper or plastic and place in a rigid outer box of wood fiberboard or very strong corrugated cardboard Use ample soft packing to prevent movement Provide additional support...

Reviews: