background image

 

The material contained in this document is the property of Electronics & Innovation Ltd., it is 
subject to change without notice.  
 

August 2012                                                                                                                             

Revision B 

 

 

This  unit  is  7.4U  high,  16.75

”  width.  With  the  handles  removed  it  will  fit  into  a 

standard rack. 
 

2.2.1 Mains Voltage 

 
The unit accommodates AC line voltages from 100 TO 240 VAC 47 

– 63 Hz.  

 

2.3 OPERATION 

 
A fixed line cord is supplied to form a connection between the mains supply and 
the rear of the unit. This is configured from the factory with a 30 A / 250 Volt plug. 
 

2.3.1 Proceed as follows: 

 

(i) 

Ensure that there is at least 3” or 7.5 cm clearance at the rear of the 
unit for air flow. 

 

(ii) 

Ensure RF input voltage is not excessive 
a.  The 1 V rms indicated maximum input voltage is 5 times the level of 

the input signal required to achieve maximum output. Input voltages 
in excess of 2 volts peak may permanently damage the instrument. 

 

(iii) 

Connect the output via a 50 ohm coaxial lead and N plug to the load. 

 
(iv) 

Connect  the input  signal via  a 50 ohm coaxial lead and N plug to the 
input connector. 

 

2.3.2 Front Panel Display 

 

The 2400L front panel has a passive LCD display designed for simplicity and 
ease of use.  During initialization, the LCD shows the software revision.  After the 
amplifier is initialized, the LCD indicates Forward Power, Reflected Power, and 
amplifier status (see figure 2.1).     

Pf:___W Pr:___W 

Status:________

 

Figure 2.1 : Front Panel Display 

Where Pf refers to forward power, Pr refers to reverse power, and Status 
indicates “OK” unless there is a fault condition, such as: 

  Overheat (heat-sink temperature is too high for reliable operation) 

  PSU fault (internal fault in the main switching power supply) 

Summary of Contents for 2400L

Page 1: ...out notice August 2012 Revision B 1 2400L Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extreme caution in handling these volt...

Page 2: ...lly operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must be returned to E I freight cos...

Page 3: ...SB pulse and any complex modulation signals The amplifier has 55 dB gain it is unconditionally stable and will not oscillate even with combinations of mismatched source and load impedance It is protec...

Page 4: ...lts RMS for all output load conditions without damage POWER OUTPUT METER True RMS power detection 3 of full scale accuracy POWER REQUIREMENTS 100 240 VAC 47 63 Hz SIZE H x W x D 13 x 16 75 x 20 inches...

Page 5: ...5 times the level of the input signal required to achieve maximum output Input voltages in excess of 2 volts peak may permanently damage the instrument iii Connect the output via a 50 ohm coaxial lead...

Page 6: ...suitable for connection to a PC or host system The communication protocol is extremely simple to facilitate readback and control with readily available terminal programs such as Hyperterm The RS 232...

Page 7: ...further amplified signal appearing at the drain of Q1 is coupled to the input of Q2 This is transformed to 50 and fed to the driver output BNC port The driver output signal is fed through a length of...

Page 8: ...bject to change without notice August 2012 Revision B 8 There are four switch mode power supply units three provide a 42 VDC 24 ampere source The other provides 42VDC and 24 VDC outputs and provides a...

Page 9: ...ail safe under all load conditions Damage can only be externally caused by the incorrect selection of the AC supply voltage or by an input signal in excess of the specified 1 volt rms equivalent to a...

Page 10: ...or c Adjust the output level of the sweep generator so that a 50 ohm video detector connected at the output of the unit will not be damaged by excessive power output Reference section 4 4 1 for set up...

Page 11: ...D151 e Attenuator 30 dB 500 Watts Bird Figure 4 1 Gain Measurement 2 Connect the equipment as shown in Figure 4 1 then proceed as follows a Set the oscilloscope to DC Time cm to Ext X and gain to l0mv...

Page 12: ...full deflection Rotate the step attenuator CCW so that the output is reduced by 50 dB g Reconnect the 2400L into the test set up of Figure 4 1 h Place the 2400L power switch to the ON position i Obser...

Page 13: ...ap the instrument in heavy paper or plastic and place in a rigid outer box of wood fiberboard or very strong corrugated cardboard Use ample soft packing to prevent movement Provide additional support...