![Eaglemaster AS-232T Instruction Manual Download Page 4](http://html1.mh-extra.com/html/eaglemaster/as-232t/as-232t_instruction-manual_3301418004.webp)
-Remote sensor by pass :
This system offer 2stage sensor optional. Within 8sec. after set arming, to press button once , the
system will give 3 short chirps and 3 lights flash, thus the shock sensor has been turn off (disable).
If press button once again within 8sec. of arming the shock sensor will turn ON again (enable).
Note:
- if remote sensor bypassed, it will be detected again by next arming.
- if armed with silent mode, to operate sensor bypass will only indicate by lights flash.
-Passive immobilizer
(programmable)
:
If set programme with this function, when turn off ignition switch for 2 minutes or you open and close the
door, it will start engine disable function right way . The LED will flash twice per second.
To disarm this function, simply press button once.
Note:
(1). Under this immobilizer mode, if ignition force been turn ON and without disarmed, the system
will be triggering after 10sec. period time.
(2).System will re-immobilizer after 30seconds, once press button and a door is not opened.
-Aux. Channel (-) output
(programmable)
:
This channel "Pink wire" is a negative (-500mA) output features, this feature can be controlled separately
of the " Window output " , " 2nd immobilizer" or "Engine keep running" . Three of the features is available
by set programme mode.
*Window close output:
If programmed with the Window output feature, this channel will outputting 40 seconds when system armed
for window close feature.
*Pager output:
*2nd immobilizer:
This feature can be controlled separately of the engine disable. This output (-500mA) is working with the
system disarmed. 40A relay is required and go with normally closed & common output.
-Emergency reset switch:
If the remote has been lost or damage, or forgot the PIN code number the owner can enter the car by using
the key. It will act the alarm. To disarm the alarm turn ignition on and press reset switch once , it will
disarm the alarm immediately. (Please ask your installer this (-) reset switch location).
Note:
after this emergency reset activated, the PIN code will resumed factory setting PIN code
"6"
.
-Power disconnecting memory :
Alarm is built in memory on main unit. Generally, after alarm power is cut off and reconnect, main unit will
read back these data make the alarm to resume.
When in disarm or arm position, power off then on , alarm will read back original position.
-Ignition safety door lock select
(programmable)
:
If set programmed with this feature, turn Ignition ON after 10 seconds the doors will auto locked , but within
this 10 seconds the door has been opened this feature will be cancelled.
When turn Ignition OFF, the doors will unlock for take off service.
-2 step disarm:
This system offers 2 step disarm. It's a feature that make it possible to silence and reset the system while it
is triggering, without disarming the system. If the system is triggered and the siren has been sounding,
pressing any button once on the remote transmitter will stop the trigger and return the unit to the armed
state.
Pager (-) output can be connected to alarm pager to become two way service.
30
85
86
87a
87
2nd Immobilizer
relay
ALARM CONTROL UNIT
Negative Pulsed output For
2nd Immobilizer
Pink wire
Cut Existing low
current fuel pump
wire or Start solenoid
Wire
Connect to Switched (+)
12Volts Ignition key on
Wiring for 2nd immobilizer