Eaglemaster AS-232T Instruction Manual Download Page 3

STANDARD FEATURES: 

-To ARM the system:

 

To arm your system within proper operation range, simply press button        once (while system in disarmed or 
Acc off position) . The system will respond one siren chirp, one lights flash, doors lock, disable engine starter, LED 
will begin flashing quickly until all sensor inputs are active - LED will start blinking slowly (flash once per second).

DEFECTIVE ZONE BYPASS:

 If armed, after 8sec. the system responds with 4 short siren chirps, it indicating that 

one of the door is not close properly. 5 short siren chirps, it indicating that hood or trunk is not close properly. The 
system will bypass that zone and still protect other zones.

AUTO RESET:

  

If a violation occurs the system will respond by sounding the siren and flashing the lights for 

approximately 30sec. before the system resets itself and continues to protect your car. If violation still occurs the 
system, siren and lights will working for 8 cycles then the system reset itself and continues to protect other zones. 

-Arm without siren chirp :

 

To arm your system without siren chirp , simply press button        once then within 3sec. press button        once. 

 

Note:

 this features is only activated under the system is in disarmed and Acc off position,.  

-To DISARM the system :

 

To disarm your system within proper operating range, simply press button        once (while system in arm position). 
The system will respond two siren chirp, two light flash, doors unlock, Enable your engine starter, LED off

INTRUSION ALERT:

 Upon disarming the system, if the vehicle is attempted or intruded, siren and lights will 

Indicates 4 chirps and 5 flashes to identify which zone was triggered. LED mode indicates the following different 
triggering
.

      

Quick flash 2 times after a pause          Sensor 1st-stage triggered

      Quick flash 3 times after a pause          Sensor 2nd-stage triggered
      Quick flash 4 times after a pause          Door switch triggered
      Quick flash 5 times after a pause          Hood/Trunk switch triggered
      Quick flash 6 times after a pause          Ignition switch triggered

.

-Disarm without siren chirp :

 

To disarm your system without siren chirp , simply press button        once then within 3sec. press button        once. 

 

Note:

 this features is only activated under the system is in armed position,.  

-Arm/Disarm sir en chirp on/off   :

(programmable)

The system provide a feature to turn OFF siren chirp when arm/diarm in silent area, disarm the system and turn 
ignition to ON position, press and hold        button for over 5sec. until siren give 2 short chirps to indicate that the 
siren chirp has been turn OFF (disable). 

  

-Automatic REARM: 

(programmable)

 

If programmed with the feature, the system is disarmed by remote and a door is not opened within approximately 40 
seconds the system will automatically rearm itself. This feature guards against disarming caused by accidental or 
unintended operation of the remote transmitter.  

To turn OFF the feature:

 Disarm the system, turn ignition from OFF to ON position and within 5 seconds press and

hold button                   for over 2 seconds, until siren give 2 shot chirps, the feature now has been turned OFF.  
To turn ON the feature again, same condition as above, siren give 1 short chirp to indicate turn ON the feature.

 

-Trunk open: 

(programmable)

 

This negative channel provide 2 ways to active the channel (Trunk open & Remote Latched), a

Note:

 if trunk has been remote opened in arming position, hood/trunk switch will delay sensing for 20 seconds, and 

          the shock sensor will be bypassed.       

 the channel 

                              may be activated immediately. However the channel may keep outputting until release the button;
                              this is particularly designed for extra devices operate. 

Note: 

as long as the channel outputting , the shock sensor will be bypassed , unless button released.  

-Dual stage shock sensor:

 

This device only activates after 8 seconds of arming state; this is preventing from the weak impact caused by the 
driver while leaving the car.  
The device operates: Light impact will activate the 1st stage sensor by giving 5 warning chirps. 
                                   Heavy impact will activate the 2nd stage sensor and trigger the alarm.

NOTE

: Adjustments are made via the rotary control above the shock sensor.

On the contrary, press and hold        button 5sec. again, siren chirp will turn 

ON again, siren will give 1 short chirp.  

lternative feature is 

available by programmable setting, please see "Programme mode operate".

-Trunk open :

 if programmed with Trunk open feature, simply press and hold button       over 2 seconds, the channel

                        will output for 1 second pulse , normally for open the trunk. 

-Remote latched:

 if programmed with Remote latched feature, press and hold button       , the channel

Summary of Contents for AS-232T

Page 1: ...ogramme mode 19 Parking light flasher 20 Doors lock unlock relays 21 Code hopping system 22 PIN code protection 23 Alarm triggering counter 24 Valet mode IMPORTANT Please read the entire manual for co...

Page 2: ...e Chirp Once Chirp Twice REMOTE FUNCTION OPERATE Functions Step Condition Press button Siren chirp confirm Trunk open Remote latched Chirp Once Chirp Twice Arm and door lock Arm without siren chirp Di...

Page 3: ...r the system is in armed position Arm Disarm siren chirp on off programmable The system provide a feature to turn OFF siren chirp when arm diarm in silent area disarm the system and turn ignition to O...

Page 4: ...system disarmed 40Arelay is required and go with normally closed common output Emergency reset switch If the remote has been lost or damage or forgot the PIN code number the owner can enter the car b...

Page 5: ...ication alarm will not allow to activated How to use your PIN code If the remote control has been lost or damaged you can manually disarm your system by enter your own PIN code The system s factory se...

Page 6: ...from Socket relay starter solenoid side Cut Existing low current Start solenoid wire Connect to Hood or Trunk Pin Switch Connect to Existing Negative Door Pin Switch GM Type Connect to Existing Positi...

Page 7: ...ck system like Mercedes Benz AUDI 2 WIRE ACTUATOR 12V GND ELECTRIC MOTOR ELECTRIC MOTOR MOTOR LOCK INSIDE THE FRONT DOOR 12V UP DOWN AIR COMPRESSOR 12V DOWN UP Note Door lock active time for 4 secs CE...

Reviews: