Operating Manual / en
eMG
page 8 / 26
Rev. 2
05/02/2020
M.S. in the stock
IMPORTANT!
Store the
seal in the original packaging
lying on a
flat surface
.
Check the packaging periodically for damage.
Sealings packed in plastic-foil with humidity indicators have to be checked every
8 weeks. The check has to be recorded.
Packaging
exceeding 50 % rel. humidity
values must be sent to the manu-
facturer or the
nearest EagleBurgmann service centre
for inspection and new
packaging.
Unused stored mechanical seal under optimum conditions:
For reasons of safety, after 3 years from delivery of the mechanical seal the M.S.
should be returned to EagleBurgmann resp. nearest EagleBurgmann Service
centre for
Exchange of all secondary seals and springs
Verification of the flatness of the faces
Perhaps static pressure test.
M.S. installed into the machine:
ATTENTION!
"Mothballing"
(long term storage) of the mechanical seals is
not allowed
.
In case of a "mothballing" (long term storage) of complete machines with mechanical
seals installed EagleBurgmann has to be contacted.
Do not
use corrosion protection agents.
Risk of deposition and possibly chemical attack of the secondary seals.
Due to longer erecting times of newly designed plant the period between delivery of
the mechanical seal and its installation and start-up in the machine may exceed a
period of 2-3 years.
After 3 years at the latest and in good time
before the planned start-up of the plant
the seal has to be dismantled sent to the manufacturer or the nearest
EagleBurgmann service centre where it can be checked and reconditioned, if
necessary.
EagleBurgmann does
not accept any warranty
for damage caused by
improper
storage.