SERVICING
Maintenance
The correctly operated mechanical seal needs
low maintenance
. Wear parts,
however, have to be replaced, if necessary.
A duly operation includes a regular check of the following parameters:
Temperature
Leakage (drainage) of the mechanical seal
An inspection of the mechanical seal should be carried out along with a revision of
the complete plant. We recommend having this inspection be performed by
EagleBurgmann.
If the mechanical seal is removed during a revision of the plant it has to be replaced
by a new one.
Directives in case of failure
Try to define the kind of failure and record it.
In the event of
excessive leakage
changes in the leakage amount
must
be
monitored. If necessary the machine has to be switched off.
A damage of the mechanical seal is indicated by a continuous, flowing leakage.
In the event of an
inadmissible
temperature rise
the machine
has to
be stopped
for safety reasons.
If there is a
malfunction
which you cannot correct on your own, or if the cause of
malfunction is not clearly recognisable please immediately contact the nearest
EagleBurgmann
agency
, an EagleBurgmann service centre or the EagleBurgmann
headquarters.
During the
warranty period
the mechanical seal must only be disassembled with
approval of the manufacturer or when a representative is present.
After-sales service by EagleBurgmann
EagleBurgmann's customer service department offers a comprehensive service
package covering consultancy, engineering, standardisation, installation,
commissioning as well as damage analysis right through to seminars on sealing
technology.
Addresses are listed in various EagleBurgmann brochures as well as under
www.eagleburgmann.com
.