![Eagle 250C User Manual Download Page 6](http://html1.mh-extra.com/html/eagle/250c/250c_user-manual_3341069006.webp)
DMX
-
GND
Digital display function & address setting explain:
This control display menu is especially designed for all kinds of computer light, fit out
multifunctional control mode, easy control. For some model products have not the motion, corresponding,
the menu option setting also null.
1
REST FUNCTION
:
Press
Down
or
Up
key, after appear
“
rSEt
”
, press Enter key, it will
“
rSEt
”
when appear
“
rSt
”
2
DMX512[Address setting]
:
This function can let you
change this equipment address setting.
Press “ESC” key or time after time, till appear
“
A.001
”
.then press Enter key, letter
“
A” crush out.
At this time, appear offside three digits. After Using “Up” or “Down” to choose the address code
which you want. And then press “Enter” is ok.
3
automatism & sound control setting
:
Press “Down” or ”Up”, appear
“
Audi
”
, and then press “Enter”, It will appear
“
OFF
”
or
“
ON
”
,
Press “Down” or ”Up” again to choose
“
OFF or On
(
OFF: automatism
,
ON: sound control
)
After choose it, pls press “Enter” key and them press” Down” or “Up” to choose
“
test
”,
press “Enter” key
again, It will appear “nod.l”, and them press “Enter” again. It will appear “run”.
At this time, it would be running base on the setting above. (Setting OFF: automatism, ON: sound control),
when running sound control, green LED will be scintillating basis sound control frequency.
4
Principal and subordinate synchronism control:
Main light setting: press Down or Up key, after appearing
“
rSEt
”
,and then press Enter key to display
“nod.1” press Down or Up to display “nast”, press Enter key again to appear “OFF” or “ ON”.
Press Down or up key to choose “OFF” or “ON”. (Choose “OFF” : this light is not the main light. Choose
“ON”: this light is the main light”). After choosing it, press Enter to fall back on “nast”.
Press Down or Up key again to display “nod.1”. Press Enter key display “run”. Means running.
(After setting the main light, DMX ‘S LED is light)
When receiving Principal and subordinate synchronism, son light must be in the status of display address
code.(if the equipment is not connect DMX controller, the display will scintillate, if the equipment is
connect DMX controller, the display won’t scintillate. But DMX signal indicator light will scintillate as
the signal. After setting ON, be sure to break off the connecting with DMX controller, and only one light
can be set to main light), it is not to change the DMX address setting of son light.
E.g. the address code son light can be set “001” or other number.