background image

4

OPERATING MANUAL AND INSTRUCTIONS

CHAIN-MOUNTED UNITS

Chain supplied by Eagle Group is constructed of sufficient strength to securely hold the weight of the RedHots

®

Heat Lamp when properly

mounted. (Ordered separately by the foot under Eagle Group, part # 358372.) 

Securely fasten the chain to surface above the area that the heat lamp will be located over. Please be sure that the chain is located so that

the heat lamp will be suspended at a safe and proper distance from any side, rear walls and working surface. (Distances provided in

“Mounting Location” section of this manual—page 3.)

Loosen the screws that hold that mounting tabs on either side of the heat lamp. Extend the tabs upward and then tighten the screws. 

Use a short piece of chain between the two tabs. Attach the overhead chain to the connecting chain to form a “Y” shape (see illustration

below) and repeat for the opposite end. 

Note: Additional chain is required to mount from overhead to each tab. 

WARNING

Chain must be #8 trade size and securely fastened, 

or unit could come loose and possibly cause personal injury or damage to the unit. 

“Y” shape chain connection

(part #358372—ordered per foot)

chain-mounted

heat lamp

(end view)

shelf

bracket 

(part #355148)

#8-32

screws

#1/4-20 screws

(not included)

heat lamp 

UNDER SHELF MOUNT

When mounting the heat lamp under a shelf, maintain a 1˝ offset from the bottom of the shelf. The heat lamp is not to be mounted

under a shelf that is considered combustible. The shelf must be made of a non-combustible material.

If the shelf has a rolled edge or downturn, the heat lamp must be below the lowest part of the roll or flanged edge, using the adjustable

bracket (supplied by Eagle Group, part #355148). The lower set of holes accommodates a 1-1/2˝ deep shelf. 

Remove the two #8-32 screws per bracket, towards the rear of the heat lamp (shown in the illustration below), and remove any

hanging clips. Align the holes in the bracket to the holes in the heat lamp, as shown below, and securely mount the screws. 

Secure the heat lamp brackets using #1/4-20 bolts/screws (hardware not provided by Eagle Group) to ensure a secure installation. 

Summary of Contents for RedHots RHHL Series

Page 1: ...tly GENERAL NOTES Eagle s RedHots Heat Lamps help keep your foods at their optimum serving temperatures while maintaining a high level of quality These heat lamps focus their heat over the entire area and provide even heat distribution to eliminate hot spots Eagle s RedHots Heat Lamps can be purchased in standard watt or high watt units with or without lights Heat lamp lengths range from 18 long t...

Page 2: ...o be wired to cord plug ELECTRICAL REQUIREMENTS Optional Control Switch Box Connection When ordering a heat lamp with a remote the main unit does not contain any switches Following UL NEC and local codes install a copper supply wire temperature rated no lower than 90C to the control box Eagle Group supplies a 7 8 and 1 1 8 knockout on the sides of the aluminum housing and 6 long 12 gauge pigtails ...

Page 3: ...ing temperatures without over cooking OPERATING MANUAL AND INSTRUCTIONS WARNING Standard Wattage Heat Lamps There must be 10 minimum distance between the bottom of the heat lamp and the top of the combustible work surface and no less than 8 between the bottom of the lamp and the top of a non combustible work surface There must be a 10 minimum distance between the bottom of the heat lamp and the to...

Page 4: ...tab WARNING Chain must be 8 trade size and securely fastened or unit could come loose and possibly cause personal injury or damage to the unit Y shape chain connection part 358372 ordered per foot chain mounted heat lamp end view shelf bracket part 355148 8 32 screws 1 4 20 screws not included heat lamp UNDER SHELF MOUNT When mounting the heat lamp under a shelf maintain a 1 offset from the bottom...

Page 5: ... Eagle Group Part Number 355148 for one bracket two brackets required Chain for Chain Mounted Units Eagle Group Part Number 358372 ordered per foot SAFETY PRECAUTIONS Only use mounting methods and materials described and suggested by Eagle Group to prevent personal injury or damage to the heat lamp and its components Be sure that all specified clearances have been maintained for safe operation and...

Page 6: ...6 RedHots Heat Lamps WIRING DIAGRAMS ...

Page 7: ...7 RedHots Heat Lamps WIRING DIAGRAMS ...

Page 8: ...actory for assistance this warranty does not cover any cost associated with maintenance misuse abuse improper installation pilot light adjustments pilot outage improper ventilation adjustments alteration calibration wrong voltage wrong gas voltage or gas conversions resetting of circuit breakers or safety controls overtime charges travel charges on portable equipment mileage in excess of 100 miles...