Engine oil is a major factor affecting engine performance and service life.  Non detergent and 2-stroke 

engine oils will damage the engine and are not recommended.

Check the oil level BEFORE EACH USE with the 

generator on a level surface and the engine stopped.

Use 4-stroke motor oil that meets or exceeds the 

requirements for API service classification SJ.

Always check the oil container for the SJ classification.

SAE 10W-30 is recommended for general, all-temperature use.  Other

viscosities shown in the chart may be used when the average temperature in your area is within  the 

indicated range.

1.  Remove the oil filler cap and wipe the dipstick clean.

2.  Check the oil level by inserting the dipstick into the filler neck without screwing it in.

3.  If the level is low, fill to the top of the oil filler neck with the recommended oil.

Engine Oil Change

Drain the oil while the engine is warm to assure rapid and complete draining.

1.  Remove the drain plug and sealing washer, remove the oil filler cap, and drain the oil.

2.  Reinstall the drain plug and sealing washer.  Tighten the plug securely.

3.  Refill with the recommended oil and check the oil level to ensure it is full.

OIL CAPACITY:  32 oz.

Wash your hands with soap and water after handling used oil.

Please dispose of used motor oil in a manner that is compatible with the environment.  We 

suggest you take it in a sealed container to your local service station or recycling center for 

reclaimation.  Do not throw it in the trash, pour it on the ground, or down a drain.

                                                                                  

6

Summary of Contents for TB9000

Page 1: ... gas engine powered industrial strength generating unit of electrical power The gas engine and the generator are both potentially extremely hazardous and could cause physical injury or even death if improperly used WARNING Do Not Operate Equipment until reading understanding Operator s Manual Disconnect all loads before starting or stopping generator Allow to run for a few minutes with no load bef...

Page 2: ...00 is a gas engine driven revolving field alternating current AC generator designed to supply electrical power for compatible electrical tools motors appliances and lighting see wattage reference guide on page 8 The Model TB9000 operates at 120 volt and or 240 volt single phase 60 Hz and will operate devices that require up to 7200 watts continuous and 8400 watts surge GROUNDING THE GENERATOR It i...

Page 3: ...bare frayed or otherwise damaged electrical cords or wiring with the generator A defective cord may result in electrical shock or may cause damage to equipment Do not expose unit to excessive moisture dirt or corrosive vapors Unit must be operated on a level surface Do not overfill the fuel tank Always allow room for fuel expansion Fuel could overflow and cause fire or explosion if tank is overfil...

Page 4: ...the generator Stopping the engine 1 Turn off all electrical devices connected to the generator 2 WARNING DO NOT start or stop generator with electrical devices plugged in 3 Allow the generator engine to run at a No Load condition for several minutes to stabilize internal engine temperature before stopping 4 Turn the On Off Switch on the Control Panel to the off position 5 Turn Fuel Valve to the Of...

Page 5: ... 10 Oil nozzle is dirty 11 Engine has lost compression 1 Out of fuel 2 Fault in engine 1 Load is too high 2 Dirty air filter 3 Engine needs to be serviced TROUBLESHOOTING Problem Cause Solution 1 Reset the circuit breaker 2 Check repair 3 Connect another device that is in good condition 4 Contact service center 1 Disconnect shorted load 2 See Connecting Electrical Loads section of manual 3 Contact...

Page 6: ...eck the oil level by inserting the dipstick into the filler neck without screwing it in 3 If the level is low fill to the top of the oil filler neck with the recommended oil Engine Oil Change Drain the oil while the engine is warm to assure rapid and complete draining 1 Remove the drain plug and sealing washer remove the oil filler cap and drain the oil 2 Reinstall the drain plug and sealing washe...

Page 7: ... 4 250 Device Running Device Watts Impact Wrench 500 Jet Pump 800 Lawn Mower 1200 Light Bulb 100 Microwave Oven 700 Milk Cooler 1100 Oil Burner on Furnace 300 Oil Fired Space Heater 140 000 BTU 400 Oil Fired Space Heater 85 000 BTU 225 Oil Fired Space Heater 30 000 BTU 150 Airless Paint Sprayer 1 3 HP 600 Handheld Airless Paint Sprayer 150 Radio 50 to 200 Refrigerator 600 Slow Cooker 200 Submersib...

Page 8: ...o 2 months Fill with fresh gasoline add gasoline conditioner 2 months to 1 year Fill with fresh gasoline add gasoline conditioner Drain carburetor bowl Drain fuel sediment cup 1 year or more Remove Spark Plus put a tablespoon of engine oil into all cylinders Turn the engine slowly with the pull rope to dis tribute the oil Reinstall spark plugs change the engine oil After removal from storage drain...

Page 9: ...ts in material and workmanship for a period of two years on th engine after date of purchase and one year on all parts and components after date of purchase Normal wear and tear on items which have exhausted their useful life is not covered LIMITED WARRANTY ...

Page 10: ... 12 3 Gallon Fuel Tank Approx Run Time 24hrs 50 Load Model TB9000 10 This unit is not for use in the state of California RPM 3720 Brushless Generator Head Copper Windings Low Oil Shut Down Oil Capacity 32oz 10w 30 Size L 32 W 28 H 26 Net Weight 360LBS 12v DC Connector One Year Equipment Warranty Two Year Engine Warranty SPECIFICATIONS Manufactured by American Fab Inc P O Box 1027 Travelers Rest SC...

Reviews: