A. All electrical connections must be carried out by a certified electrician in accordance with the
local electrical requirements and codes.
B. INSTALLATION PROCEDURES
C. WARNING: When installing jet massage baths, air massage baths, or dual massage baths,
basic precautions should be followed, including the following:
D. Danger: Risk of electrical shock. Connect only to a separate circuit protected by a ground
fault circuit interrupter (GFCI)
E. Installation must provide access for servicing pump/ motor (all Tubs come with an access
panel for the pump/motor and faucet).
1. Install tub waste according to instructions provided with fitting.
2. Install faucet. If spout and supply lines are to be installed on deck of tub, mark the
locations and drill pilot holes from the side of product. Using proper size hole-saw,
drill spout, hand shower and supply lines from side of the product.
3. Standard installation – After framing is complete, set product in place to check fit and
make certain that the tub can be properly leveled. (Caution: if walk in bathtub is not
resting on ALL leveling feet, water will not drain properly and may cause the door to
leak).
F. Warning: Never allow the weight of the tub to be supported by wood support stringers and
do not use tile flange on the 60x32 to screw or nail in place, as this will result in product
failure and void the warranty.
4. Verify the product is completely level by checking tub surface and ensure ALL
leveling feet are touching the ground.
5. Electrical connection is made by simply plugging pump cord (shipped with cord and
plug) into specified dedicated 120V, 20A, GFCI outlet.
6. After plumbing and electrical connections have been made the tub should be cleaned
of dirt and debris.
7. Installation is not complete until the bath has been tested in place.