Product Manual Mona Switch V2 

EAE KNX Mona Series

                                                                                    

MONA Switch R3.0

 

©

EAE Technology                                              www.eaetechnology.com                                                               Page 1 / 34 

EAE MONA SWITCH V2

 

 
 
 

 

 
 
 
 
 

 

 

Summary of Contents for MONA SWITCH V2

Page 1: ...Product Manual Mona Switch V2 EAE KNX Mona Series MONA Switch R3 0 EAE Technology www eaetechnology com Page 1 34 EAE MONA SWITCH V2...

Page 2: ...General 10 4 1 1 Parameters 10 4 1 2 Communication Objects 12 4 2 LED Brightness 13 4 2 1 Parameters 13 4 2 2 Communication Objects 13 4 3 LED Color 14 4 3 1 Parameters 14 4 3 2 Communication Objects...

Page 3: ...ACK MN W S04 MONA 4 BUTTON SW WHITE MN B S05 MONA 5 BUTTON SW BLACK MN W S05 MONA 5 BUTTON SW WHITE MN B S06 MONA 6 BUTTON SW BLACK MN W S06 MONA 6 BUTTON SW WHITE MN B S07 MONA 7 BUTTON SW BLACK MN W...

Page 4: ...of functional flexibility up to 12 programmable buttons Mona switches can be programmed for control lighting shutter blind drivers speakers make scene calls and mimic panic buttons Each button can be...

Page 5: ...via the KNX bus Current drawn from bus 25 mA Connections KNX Bus Connection Operating Temperature Ambient 5 C 45 C Storage 25 C 55 C Humidity Max Air humidity condensation 95 no moisture Dimensions F...

Page 6: ...12 Long Press Repeat 1 Button 1 12 Long Press Release 1 Value 1 bit 1 bit DPT 1 001 CT Value 1 bit HVAC Control Mode 1 bit DPT 1 100 CT Value 1 bit toggle 1 bit DPT 1 001 CT Value 2 bit priority contr...

Page 7: ...ol Mode 1 bit DPT 1 100 CT Value 1 bit toggle 1 bit DPT 1 001 CT Value 2 bit priority control 2 bit DPT 2 001 CT Value 4 bit dimming control 4 bit DPT 3 007 CT Value 4 bit blind control 4 bit DPT 3 00...

Page 8: ...d 2 Byte DPT 7 001 CT Value 2 byte signed 2 Byte DPT 8 001 CT Value 2 byte float 2 Byte DPT 9 001 CT Value 3 byte color 3 Byte DPT 232 600 CT Value 4 byte unsigned 4 Byte DPT 12 001 CT Value 4 byte si...

Page 9: ...07 CW 75 LED Brightness Custom Level 0 Off 1 7 1 Byte DPT 5 010 CRW T LED Brightness Custom Level 0 0 Off 0 4 100 1 7 1 Byte DPT 5 001 CRW T LED Brightness Custom Level Raw 0 Off 0 4 100 1 Byte DPT 5...

Page 10: ...Limiter checked Maximum number of telegrams to send in telegram limit period duration Telegram Transmission Delay 1 255 This parameter is used to set delay for sending the first telegram when device...

Page 11: ...Parameter Settings Description LOGIC BLOCKS Logic Blocks None 1 2 This parameter is used to select logic block count DIAGNOSTICS Firmware Version Read Firmware Version Device Firmware version will be...

Page 12: ...g Mode 0 Disable 1 Enable 1 bit DPT 1 003 CW 0 Enable 1 Disable 1 bit DPT 1 006 This object is used to activate lock for all buttons on device 146 161 IN1 IN2 OUT15 IN3 OUT14 IN15 OUT2 OUT1 Logic Bloc...

Page 13: ...level for Status LEDs can be changed via object Parameter Setting Description BRIGHTNESS LEVELS Bright Level 0 OFF 1 2 3 4 5 6 7 The bright dim level can be set Dark Level 0 OFF 1 2 3 4 5 6 7 The dar...

Page 14: ...ustom Color Red Yellow Green Cyan Blue Magenta White This parameter is used to select the type of color changes for custom color option Custom Color Object checked unchecked This parameter allows to c...

Page 15: ...Cleaning Mode deactivation method If No selected Mode can be deactivated via object only If Any Button selected Mode can be deactivated touching long to any button as Long Press Duration below Long P...

Page 16: ...aetechnology com Page 16 34 4 4 2 Communication Objects No Object Name Function Data Point Type Flags 73 Cleaning Mode 0 Disable 1 Enable 1 bit DPT 1 003 CW 0 Enable 1 Disable 1 bit DPT 1 006 This obj...

Page 17: ...0 Night 1 Day 1 bit DPT 1 006 This object switches Day and Night information thru com object Device LEDs will be dimmed UP or DOWN If Ambient Light dim is properly configured Parameter Setting Descri...

Page 18: ...nd Object This parameter is used select the proximity type Presence Timeout 1 10 255 s This parameter defines the timeout for Presence When it is reached the device will be in Absent mode and dimming...

Page 19: ...Red Yellow Green Cyan Blue Magenta White Custom Push buttons also have status LEDs which can be configured to indicate state of the operation that is configured Parameter Settings Description Name Max...

Page 20: ...ts button function when button touched Command on Release On Off Toggle No command Selects button function when button released Separate Switch Status Object checked unchecked This parameter defines t...

Page 21: ...ty Start Stop and Step Wise Dimming Start Stop Type When push button touched and not released and touched duration exceeds Long Touch Duration time Increase 100 When button in Brighter mode or Decreas...

Page 22: ...01 CRW Button 1 12 Lock T 1 bit DPT 1 001 CRW Parameter Settings Description Dim Operation Darker Short Touch Off Brighter Short Touch On Darker Brighter Short Touch Toggle Select push button dim oper...

Page 23: ...Product Manual Mona Switch V2 EAE KNX Mona Series MONA Switch R3 0 EAE Technology www eaetechnology com Page 23 34...

Page 24: ...on Function parameter enables the use of push button 3 different ways Up Long Press moves the blind upwards Short Press operates two different ways short pressed while the blind is moving stops the bl...

Page 25: ...es the use of push button 3 different ways Up Short Press moves the blind upwards Short Press stops the blind Down Short Press moves the blind downwards Short Press stops the blind Toggle Short Press...

Page 26: ...bit DPT 1 001 CRW Button 1 12 Lock T 1 bit DPT 1 001 CRW Parameter Settings Description Push Button Function Up Down Toggle See Chapter 4 6 3 Control Type Venetian Blind Roller Shutter button operati...

Page 27: ...e unsigned 2 byte signed 2 byte float 3 byte color 4 byte unsigned 4 byte signed 4 byte float Data type can be selected individually for each Value field Value 0 1 Visible when Data Type selected as 1...

Page 28: ...e learn Multi Press Timeout 20 200 x10 ms Double or Triple press action time period Long Press Duration 100ms 500ms 10s Select time period for long press operation Repeat Long Press Telegram checked u...

Page 29: ...CT 3 9 15 21 27 33 39 45 51 57 63 69 Value 1 byte counter sequence 1 Byte DPT 5 010 CWT Value 1 byte scene activate 1 Byte DPT 18 001 CT Value 1 byte scene learn 1 Byte DPT 18 001 CT Value 2 byte uns...

Page 30: ...ould be selected in this page Parameter Setting Description I O Config 1 Input 15 Output 2 Input 14 Output 3 Input 13 Output 4 Input 12 Output 5 Input 11 Output 6 Input 10 Output 7 Input 9 Output 8 In...

Page 31: ...value the result will be True NOT equal If the Input value is NOT equal to ETS written value the result will be True in range If the Input value is in range between written values on ETS the result w...

Page 32: ...sed as it is NOT Input will be reverted always True Process will always be True regardless to input value always False Process will always be False regardless to input value Initial State False True T...

Page 33: ...r All 1 s Passthrough It should be used with single operand only Result will be the same as related operand value NOT It should be used with single operand only Result will be reverted according to re...

Page 34: ...output sending If selected Input or Registered Output has its selected value Send pending telegram after unblocking unchecked checked This function is used to send output state after unblocking Send...