AC voltage: the voltage of the utility
grid
AC current: the current of the utility
grid
8
10 S
Frequency: the frequency of the utility
grid
Output Power: 1000 W
9
10 S
Cumulative energy generation time
10
10 S
Inverter SN: The SN of the Inverter
EE00S005000001A1
11
10 S
Working Mode:
DRM(Demand
response
mode)
Number:
12
10 S
This menu indicates the current
country grid code or safety standards
selected
Users are able to view those info without password including country grid
code. cAUSAS4777_2A, cAUSAS4777_2B, cAUSAS4777_2C and cNZS4777_2
represent Australia A, Australia B, Australia C and New Zealand standard
respectively.
6.2.3
BASIC SETUP
You can set time and address in this sub-menu.
No.
Display
Explanation
1
To set up time
2
To set up RS485 address
3
To set up language
6.2.3.1 Time Setting-up
When the sub-menu of ‘SET TIME’ is selected, the LCD will display the screen
as below.
Press ENT to move the cursor from left to right, Press UP/DOWN to select a
number for a selected digit. Press ESC to save the setting and return to the
main menu.
6.2.3.2 Address Setting-up
The inverter RS 485 address communicating with a monitoring platform can
be set here, the address ranges from ‘01’ to ‘99’, and the default address is
‘01’.
Press UP/DOWN to scroll through numbers for a selected digit, press ENT to
save the setting and return to the main menu, and press ESC to return to the
main menu without saving the setting.
6.2.3.3 Language Setting-up
Working language of the inverter can be set here, and the default language is
English.
6.2.4 Detail Info - Maintenance Personnel Only
Select ‘Detail Info’ from the main menu and the LCD screen will display the
following information:
AC VOL: 230.6V
AC CUR: 38.8A
TOTAL RUNTIME:
152 H
INVERTER SN
EE00S005000001A1
SET TIME
SET RS485 ADDR
NEXT = ENT OK = ESC
25-01-2022
18:23
YES = ENT EXIT = ESC
Slave Add: 01
GRID FREQ:50.2Hz
POWER : 1000 W
SET LANGUAGE
MODLE:
Volt-Watt
Standard
cAusas4777_2A