Connection / Programming

2.  The interface connectors

2.1 RS 232-C Interface

Pin assignment of the 9pole Sub-D socket for the serial interface:

1  

-   

 

 

6  

DSR

2  

RXD    

 

7  

RTS

3  

TXD    

 

8  

CTS

4  

DTR    

 

9  

-

5  

Signal ground

2.1.1 Baud rate selection RS232

The serial port on the Ethernet interface board uses certain communication parameters which can not be changed. 

Before using the port for communication, make sure to set the software tools on the PC to the same settings. See 

technical specification on page 10.

2.1.2 Serial cable for the RS232

For the connection of the RS232 port on the device to a PC it requires a standard 9pole 1:1 D-sub cable.

2.1.3 Ethernet interface

The Ethernet interface settings on the device are limited to a variable IP address. Changing the IP to a desired value 

can be done using either the RS232 port via serial cable and terminal software or by a special SCPI command via 

standard network connection (Ethernet patch cable, CAT5).

3.  First operation and setup
3.1 Setting IP address

The default IP address 192.168.0.163 can be changed to any other custom value before or after the device has been 

installed on the target location. Which of both ports to use for programming the IP depends on the situation. Being 

connected to the network, the device can be accessed at the default IP address and re-programmed. This is the simp-

ler method. Alternatively, the serial port of any PC or notebook can be used, if present. After changing the IP address 

by any of both methods, the device has to be completely switched off and on again to activate the new IP address.

Note

As long as there is serial cable connection between the RS232 port of the device and a PC, either for IP program-

ming or normal remote control, the Ethernet port remains deactivated.

3.1.1 Programming the IP address via RS232 port

Steps to perform:

1. Switch device off, connect serial cable (1:1) from device to PC

2. Start terminal software on the PC, for example Hyperterminal, and use following settings in the software:

  - COM port: depends on which port of the PC the cable is connected to

  - Serial settings: Baud rate 9600 Bd, no parity, 8 data bits, 2 stop bits, 1 start bit, CTS/RTS handshaking

  - Termination character: CR (0xD, 13) or LF (0xA, 10) or both

  The termination character is required. Depending on the terminal software that is used, the character may already 

be sent when hitting the return key. Otherwise it has to be included in the message.

3. Start the serial connection and switch the device on --> the message „

Press any key to continue

“ should appear in 

the terminal software log window. Press any key or send any single character, for example „y“.

4. Now there should appear another request: „

Program IP address?

“ --> This has to be confirmed with the „y“ key or 

by sending the „y“ character, else the IP programming procedure is canceled.

5. A  prompt  should  appear  with  „y“,  requesting  you  to  enter  the  new  IP  address:  „

Enter  the  IP  address  (eg. 

10.10.10.163)>

“ --> enter the new IP here in the standard format and as pure text, for example 192.168.0.10, and 

submit with return key or by sending the IP string followed with a termination character. The device will ask back with 

Is <ip> correct?

“. In order to finally program the IP address, this has to be answered with „y“ key or „y“ character. 

Once successfully programmed, there will be a message „

IP address successfully programmed

“.

Note

In case the question „

Is <ip> correct?

“ has been mit negated with „n“ , because the entered IP address was wrong, 

the whole procedure has to be repeated from step 1.

Summary of Contents for HV 9000

Page 1: ...Bedienungsanleitung Operation manual Ethernet Interface PS 9000 HV 9000 Art Nr 61100104...

Page 2: ......

Page 3: ...steuerung verlassen 7 5 SCPI Programmierung 8 5 1 SCPI Befehle 8 5 2 Standard IEEE Befehle 8 5 3 Zuweisung der Meldesignale bei Abfrage mit STAT QUES 9 English Page 1 Introduction 11 1 1 Basic items t...

Page 4: ...e Abweichung vom vorgegebenen Wert Sollwert und tats chlichem Wert Istwert Dieser Fehler ist bedingt durch Toleranzen aller Bauteile die an der Erzeugung von Sollwerten bzw der Messung von Istwerten b...

Page 5: ...den auf Null gesetzt Die Leistung kann von der Schnittstelle nicht gestellt werden und mu daher an der analogen Schnittstelle vorgegeben werden Siehe unten Strom und Spannung m ssen bei Fernsteuerung...

Page 6: ...sse zu bernehmen Hinweis Solange das Ger t ber serielles Kabel am RS232 Port zum PC verbunden ist zum Programmieren der IP Adresse oder zur Fernsteuerung ist der Ethernetport inaktiv 3 1 1 Programmier...

Page 7: ...4 1 Fernsteuerung aktivieren Die Fernsteuerung mu nicht explizit mit einem bestimmten Befehl aktiviert werden Jeder beliebige erste Befehl au er RST nach dem Einschalten des Ger tes oder nach einem R...

Page 8: ...Netzger tes in Volt VOLTage Meldet den zuletzt programmierten Wert der Spannungswert zur ck kein Istwert Beispiel VOLT 5 5 Setzt 5 5V Ausgangsspannung am Netzger t Beispiel VOLT Fragt den zuletzt gese...

Page 9: ...senes Bit ist 1 Signal inaktiv oder nicht verdrahtet zugewiesenes Bit ist 0 Folgende Zuordnung f r PS9000 neu 1 5 9kW HV9000 Bit 0 1 2 CP 3 4 OT 5 Mains OK 6 OVP 7 CC CV CC CV Die Bedeutung der Signal...

Page 10: ...et value and the true value actual value on the output This is error comes from the sum of tolerances of any component that is involved in the output value generation or actual value measuring The err...

Page 11: ...ered the power supply will automatically switch to external control and the set values for current and voltage are set to zero Current and voltage have to be set both during remote control It means yo...

Page 12: ...is serial cable connection between the RS232 port of the device and a PC either for IP program ming or normal remote control the Ethernet port remains deactivated 3 1 1 Programming the IP address via...

Page 13: ...he new IP address can be accessed now 4 Remote control Remote control of the power supply is basically dedicated to the Ethernet port and via network connection 4 1 Activating remote control Remote co...

Page 14: ...e of the programmed voltage this is not an actual value Example VOLT 5 5 Sets 5 5V output voltage at the power supply Example VOLT Queries the most recent set value CURRent value Programs the output c...

Page 15: ...als can be queried at which model Following generally applies Signal active assigned bit is 1 Signal inactive or not wired assigned bit is 0 Following assignment applies for PS9000 1 5 9kW HV9000 Bit...

Page 16: ...EA Elektro Automatik GmbH Co KG Entwicklung Produktion Vertrieb Helmholtzstra e 31 33 41747 Viersen Telefon 02162 37 85 0 Telefax 02162 16 230 ea1974 elektroautomatik de www elektroautomatik de...

Reviews: