® 8k/4k CL Color
41
e2v semiconductors SAS 2014
6.3.7
Privilege Level
There are 3 privilege levels for the camera :
Factory (0) : Reserved for the Factory
Integrator (1) : Reserved for system integrators
User (2) : For all Users.
The Cameras are delivered in Integrator mode. They can be locked in User mode and a specific password is required to
switch back the Camera in Integrator mode. This password can be generated with a specific tool available from the
hotline ([email protected])
This function is available in the Privilege section :
Privilege level Management (
PrivilegeLevel
) :
Get the current Camera privilege level..
Read function : “r lock” : Get the current privilege
Returned by the camera : 0 to 2
Write function : “w lock <val>” : <val> is as follow
2 : Lock the Camera in Integrator or “privilege User”
<computed value> : Unlock the Camera back in Integrator mode
6.3.8
Save & Restore Settings
The settings (or Main configuration) of the Camera can be saved in 4 different User banks and one Integrator bank. This
setting includes also the FFC and LUT enable
This function is available in the Save & Restore Settings section :
Load settings from Bank
:
Allows to restore the Camera settings.
Read function : “r rcfg” : Get the current Tap Bank in use
Write function : “w rcfg <val>” : Load settings from bank <val> (0: Factory , 1 to 4 for Users, 5 for Integrator)
Save settings to Bank
:
Allows to save the Camera settings in User or Integrator Bank
Write function : “w scfg <val>” : Save the current settings in the User bank <val> (1 to 4 for User, 5 for Integrator)
The integrator bank (User Set5) can be written only if the Camera is set in integrator mode (Privilege level = 1).
This integrator bank can be used as a « Factory default » by a system integrator.
Configuration Bank Usage
At the power up :
Last User Bank used is loaded in RAM
“Integrator” Bank (5) can be locked by switching the Camera in “User” mode (cf : Privilege feature). Then it can’t be
saved any more without switching back the Camera in “Integrator” Mode.
Ram Memory
Save
Load
Factory
Integrator
User1
User2
User3
User4
User
banks
Load
Save