Read function : “
r fga1
”;
Return by the camera: Value from 0 to 880 corresponding to a Gain range of 0 to 31dB by step of
0,0351dB
Ö
Write function : “
w fga1
” <int> ;
•
Analog even Gain
:
Set the Amplification Gain on the even Tap
.
Ö
Read function : “
r fga2
”;
Return by the camera: Value from 0 to 880 corresponding to a Gain range of 0 to 31dB by step of
0,0351dB
Ö
Write function : “
w fga2
” <int> ;
•
Analog Offset
:
Set the global Offset
.
This command is available in the CommCam “Gain & Offset”
section :
Ö
Read function : “
r offs
”;
Returned by the camera : Value from 0 to 255 which is equivalent to 16 LSB by steps of 0,063
LSB (8 bits)
Ö
Write function : “
w offs
” <int> ;
6.3.5
Save & Restore Settings
The settings of the Camera can be saved in one User bank.
The Factory default settings can be load from its dedicated memory bank.
•
Save & restore settings
:
Allows to save or restore all the Camera settings : This command is
available in the CommCam “Save & Restore Settings” section :
Ö
Write function
“
w lcfg 0
” : Load settings from the Factory default settings
“
w lcfg 1
” : Load settings from the User Bank
“
w scfg
1