European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           www.e2s.com              Tel: +44 (0)20 8743 8880 

Document No. D251-00-601-IS      Issue 1             20-09-2022                       Sheet 7 of 7

 

IECEx Approval 

 

The  IS-mC1  Combined  Sounder  /  Beacon  has  also  been 

approved to the IECEx scheme.  

 

The installation requirements for IS-mC1 combined sounder / 

beacon approved to the IECEx scheme are the same as the 

installation  requirements  for  IS-mC1  combined  sounder  / 

beacon approved to the ATEX directive. 

 

Certificate No. 

IECEx SIR 06.0045X 

 

Marking:  

Ex ia IIC T4 Ga (Ta = -40ºC to +60ºC) 

 

Standards: 

IEC 60079-0:2017 

 

 

IEC 60079-11:2011

 

IEC 60079-26:2014-10 

 

 

 

CONDITIONS  OF  CERTIFICATION  (as  stated  on  the  IECEx 

Certificate of Conformity IECEx SIR 06.0045X) 

 

  The  equipment  has  an  ingress  protection  rating  of 

IP65.  However,  if  it  has  been  supplied  without  a 

cable  entry  device,  then  the  user  shall  ensure  that 

the  devices  that  are  fitted  will  provide  an  ingress 

protection  that is  appropriate  to  the  environment  in 

which it is installed i.e. IP20 on better. If only one of 

the  two  cable  entries  are  used,  then  the  unused 

entry  ‘knockout’  shall  be  left  intact  or  fitted  with  a 

blanking  device  that  ensues  ingress  protection 

appropriate to the environment in which it is installed 

i.e. IP20 or better.  

 

 

The  total  capacitance  connected  to  Sounder 

Terminals  +  w.r.t.  Terminals  -  (i.e.  the  capacitance 

of  the  cable  plus  any  other  capacitance)  shall  not 

exceed 83nF.

 

 

  The enclosure is non-conducting and may generate 

an  ignition-capable  level  of  electrostatic  charges 

under  certain  extreme  conditions.  The  user  should 

ensure  that  the  equipment  is  not  installed  in  a 

location  where  it  may  be  subjected  to  external 

conditions  that  might  cause  a  build-up  of 

electrostatic  charges  on  non-conducting  surfaces, 

additionally,  cleaning  of  the  equipment  should  be 

done only with a damp cloth. 

 

  The  equipment  shall  only  be  supplied  via  Sounder 

Te w.r.t. Sounder Terminal - from a barrier 

having a maximum open circuit voltage Uo that is < 

28V and a maximum short circuit current Io that is < 

93mA, where Io is resistively limited. 

 

  If  not  already  fitted  optional  internal  wiring 

connections  between  Sounder  Terminals  +  /  -  and 

Beacon  Terminals  +  /  -  may  be  fitted  by  the  user. 

The  wiring  used  for such  connections  shall  have a 

minimum radial thickness of insulation of 0.5mm. 

 

The IS-mC1 combined sounder / beacon is marked with the 

certification  requirements  for  the  ATEX  and  IECEx  and 

approvals. 

e

2S

european safety systems ltd. 

London W3 7QH UK

WARNING: 

TO AVOID A POSSIBLE ELECTROSTATIC

 

CHARGE ONLY CLEAN WITH A DAMP CLOTH 

IS-mC1 

Combined Sounder / Beacon

II 1G        Ex ia IIC T4 Ga (-40ºC <=Ta<= +60°C)

2813

SIRA 05ATEX2084X

Year / Ser. No. 

09 / 1MCR000001

Sounder Te w.r.t. Terminal -

Ui = 28V    Ii = 93mA    Pi = 660mW    Ci = 0     Li = 0   

    

Sounder Terminals S2&S3 w.r.t. Terminal -

Ui = 28V   Ii = 0mA   

www.e2s.com

Beacon Te w.r.t. Terminal -

Ui = 28V  Ii = 660mA  Pi = 1.2W  Ci = 0  Li = 0       

IECEx SIR 06.0045X

 

UKEX Approval 

 

The IS-mC1 Sounder has also been approved to the UKEX 

scheme. 

 

The installation requirements for IS-mC1 sounders approved 

to the UKEX scheme are the same as the installation 

requirements for IS-mC1 sounders approved to the ATEX 

directive. 

 

Certificate No. 

CSAE 21UKEX2553X 

 

Marking:  

Ex ia IIC T4 Ga (Ta = -40ºC to +60ºC) 

 

Standards:  

EN IEC 60079-0:2018 

EN60079-11:2012 

IEC60079-26:2014 

 

The IS-mC1 sounders are marked with the certification 

requirements for the UKEX approval.  

 

 

 

FM Approval 

 

The IS-mC1 Combined Sounder / Beacon has also been FM 

Listed. 

 

Marking:           IS Class I, Zone 0, AEx ia IIC T4 

 

 

          IS Class I, Division 1, Groups A, B, C, D 

 

See  the  Control  Drawings  D  5037  Sheets  1  and  2  for 

installation details and entity parameters. 

WARNINGS:

IS-mC1 Combined 

SOUNDER / BEACON

              To prevent ignition of flammable or combustible

              atmospheres, disconnect power before servicing

 

Substitution of components may impair safety 

FM

APPROVED

IS Class l, Division 1, Groups A, B, C, D

IS Class I, Zone 0, AEx ia IIC T4 (-40ºC <=Ta<= +60°C)

e

2S

european safety systems ltd.  London W3 7QH UK

Control Drawing D 5037

www.e2s.com

Year / Serial No. 09 / 1MCR000001

TO AVOID A POSSIBLE ELECTROSTATIC

 CHARGE ONLY CLEAN WITH A DAMP CLOTH 

 

Summary of Contents for Minialert IS-mC1

Page 1: ...but at supply voltages above 16V the internal current limit will function and therefore it is recommended that they are not operated continuously with a direct supply greater than 16V IS mC1 Sounder S...

Page 2: ...e that the equipment is not installed in a location where it may be subjected to external conditions that might cause a build up of electrostatic charges on non conducting surfaces additionally cleani...

Page 3: ...nd remove the sounder beacon section from the base by turning it anti clockwise Ensure that the O ring seal remains in place b Remove the required 20mm knockout section s depending on system wiring an...

Page 4: ...meet the requirements for the sounder section see section 4 3 Hazardous Area IS mC1 Beacon IS mC1 Sounder 0V Power Supply Safe Area Barrier On Off 28V 93mA Positive Fig 7 Combined Unit wired for simu...

Page 5: ...Intermittent 800Hz 0 25s ON 1s OFF Alternating 544Hz 100ms 440Hz 400ms NFS 32 001 Motor Siren Slow rise to 1200Hz Motor Siren Slow rise to 800Hz Continuous 1200Hz Motor Siren Slow rise to 2400Hz Inte...

Page 6: ...rictive but care should be taken not to exceed a capacitive limit of 83nF for installations when very long cables are used 9 Volume Control The output level of the IS mC1 Combined Sounder Beacon can b...

Page 7: ...ounder Terminal w r t Sounder Terminal from a barrier having a maximum open circuit voltage Uo that is 28V and a maximum short circuit current Io that is 93mA where Io is resistively limited If not al...

Page 8: ...uoted and for which the output is non ignition capable for the Class Division or Zone and Group of use 7 The IS mC1 Combined Unit enclosure has an ingress protection rating of IP 65 If supplied withou...

Page 9: ...ospheres disconnect power before servicing 8 Substitution of components may impair safety 9 The total capacitance connected to terminals of the sounder i e Ccable plus any other capacitance shall not...

Page 10: ...2018 EN 60079 11 2012 IEC 60079 26 2014 Regulation EU No 305 2011 Construction Products Regulation CPR IS mA1 tones 2 3 9 15 16 17 only Notified Product Certification Body for Certificate of Constanc...

Page 11: ...and Place of Issue London 23 12 2020 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Page 12: ...EU No 305 2011 Construction Products Regulation CPR IS mA1 tones 2 3 9 15 16 17 only Notified Product Certification Body for Certificate of Constancy of Performance or EC Type Examination Certificate...

Page 13: ...and Place of Issue London 04 02 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Reviews: