E2S IS-D105 Instruction Manual Download Page 5

_______________________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)20 8743 8880 

                                                                                                                                                             www.e2s.com             Fax: +44 (0)20 8740 4200 
Document No. D187-00-001-IS      Issue 3                 13-01-20                      

Sheet 5 of 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

Tone 
Number 

 

 

Tone Description 

 
Switch 
Settings 
1 2 3 4 5 6 

 
Second 
Stage 
Alarm 

 
Third 
Stage 
alarm 

 
Tone 1 
Tone 2 
Tone 3 
Tone 4 
Tone 5 
Tone 6 
Tone 7 
Tone 8 
Tone 9 
Tone 10 
Tone 11 
Tone 12 
Tone 13 
Tone 14 
Tone 15 
Tone 16 
Tone 17 
Tone 18 
Tone 19 
Tone 20 
Tone 21 
Tone 22 
Tone 23 
Tone 24 
Tone 25 
Tone 26 
Tone 27 
Tone 28 
Tone 29 
Tone 30 
Tone 31 
Tone 32 
Tone 33 
Tone 34 
Tone 35 
Tone 36 
Tone 37 
Tone 38 
Tone 39 
Tone 40 
Tone 41 
Tone 42 
Tone 43 
Tone 44 
Tone 45 
Tone 46 
Tone 47 
Tone 48 
Tone 49 

 
 Continuous 340Hz 
 Alternating 800/1000Hz @ 0.25s intervals 
 Slow whoop 500/1200Hz @ 0.3Hz with 0.5s gap repeated 
 Sweeping 500/1000Hz @ 1Hz 
 Continuous 2400Hz 
 Sweeping 2400/2900Hz @ 7Hz 
 Sweeping 2400/2900Hz @ 1Hz 
 Siren 500/1200/500Hz @ 0.3Hz 
 Sawtooth 1200/500Hz @ 1Hz - 

D.I.N.

 

 Alternating 2400/2900Hz @ 2Hz 
 Intermittent 1000Hz @ 1Hz 
 Alternating 800/1000Hz @ 0.875Hz 
 Intermittent 2400Hz @ 1Hz 
 Intermittent 800Hz 0.25s ON, 1s OFF 
 Continuous 800Hz 
 Intermittent 660Hz 150Ns ON, 150ms OFF 
 Alternating 544Hz (100ms) / 440Hz (400ms) – 

NFS 32-001

 

 Intermittent 660Hz 1.8s ON, 1.8s OFF 
 Sweep 1400Hz to1600Hz up 1s 1600Hz to 1400Hz down 0.5s 
 Continuous 660Hz 
 Alternating 554/440Hz @ 1Hz 
 Intermittent 544Hz @ 0.875Hz 
 Intermittent 800Hz @ 2Hz 
 Sweeping 800/1000Hz @ 50Hz 
 Sweeping 2400/2900Hz @ 50Hz 
 Simulated bell 
 Continuous 554Hz 
 Continuous 440Hz 
 Sweeping 800/1000Hz @ 7Hz 
 Continuous 300Hz 
 Sweeping 660/1200 @ 1Hz 
 Two Tone Chime 
  Intermittent 745Hz 
  Alternating 1000/2000Hz @ 0.5s – 

Singapore 

  420Hz @ 0.625s - 

Australian Alert

 

  500-1200Hz 3.75s / 0.25s - 

Australian Evacuate

 

  Continuous 1000Hz  
  Continuous 2000Hz  
  Intermittent 800Hz 0.25s ON 1s OFF 
  Alternating 544Hz (100ms) / 440Hz (400ms) – 

NFS 32-001

 

  Motor Siren – Slow rise to 1200Hz 
  Motor Siren – Slow rise to 800Hz 
  Continuous 1200Hz  
  Motor Siren – Slow rise to 2400Hz 
  Intermittent 1000Hz 1s ON, 1s OFF 
  Sawtooth 1200/500Hz @ 1Hz - 

D.I.N.

 

(PFEER P.T.A.P)

 

  Intermittent 1000Hz 1s ON, 1s OFF – 

PFEER General Alarm

 

  420Hz @ 0.625s - 

Australian Alert

 

  500-1200Hz 3.75s / 0.25s - 

Australian Evacuate

 

 

0 0 0 0 0 0 
1 0 0 0 0 0 
0 1 0 0 0 0 
1 1 0 0 0 0 
0 0 1 0 0 0 
1 0 1 0 0 0 
0 1 1 0 0 0 
1 1 1 0 0 0 
0 0 0 1 0 0 
1 0 0 1 0 0 
0 1 0 1 0 0 
1 1 0 1 0 0 
0 0 1 1 0 0 
1 0 1 1 0 0 
0 1 1 1 0 0 
1 1 1 1 0 0 
0 0 0 0 1 0 
1 0 0 0 1 0 
0 1 0 0 1 0 
1 1 0 0 1 0 
0 0 1 0 1 0 
1 0 1 0 1 0 
0 1 1 0 1 0 
1 1 1 0 1 0 
0 0 0 1 1 0  
1 0 0 1 1 0 
0 1 0 1 1 0 
1 1 0 1 1 0 
0 0 1 1 1 0 
1 0 1 1 1 0 
0 1 1 1 1 0 
1 1 1 1 1 0 
0 0 0 0 0 1 
1 0 0 0 0 1 
0 1 0 0 0 1 
1 1 0 0 0 1 
0 0 1 0 0 1 
1 0 1 0 0 1 
0 1 1 0 0 1 
1 1 1 0 0 1 
0 0 0 1 0 1 
1 0 0 1 0 1 
0 1 0 1 0 1 
1 1 0 1 0 1 
0 0 1 1 0 1 
1 0 1 1 0 1 
0 1 1 1 0 1 
1 1 1 1 0 1 
0 0 0 0 1 1 

 
Tone 2 
Tone 17 
Tone 2 
Tone 6 
Tone 3 
Tone 7 
Tone 10 
Tone 2 
Tone 15 
Tone 7 
Tone 2 
Tone 4 
Tone 15 
Tone 4 
Tone 2 
Tone 18 
Tone 2 
Tone 2 
Tone 2 
Tone 2 
Tone 2 
Tone 2 
Tone 6 
Tone 29 
Tone 29 
Tone 2 
Tone 26 
Tone 2 
Tone 7 
Tone 2 
Tone 26 
Tone 26 
Tone 2  
Tone 38 
Tone 36 
Tone 35 
Tone 9 
Tone 34 
Tone 23 
Tone 31 
Tone 2 
Tone 2 
Tone 2 
Tone 2 
Tone 38 
Tone 47 
Tone 46 
Tone 49 
Tone 26 
 

 
Tone 5 
Tone 5 
Tone 5 
Tone 5 
Tone 20 
Tone 5 
Tone 5 
Tone 5 
Tone 2 
Tone 5 
Tone 5 
Tone 5 
Tone 5 
Tone 5 
Tone 5 
Tone 5 
Tone 27 
Tone 5 
Tone 5 
Tone 5 
Tone 5 
Tone 5 
Tone 5 
Tone 5 
Tone 5 
Tone 15 
Tone 5 
Tone 5 
Tone 5 
Tone 5 
Tone 5 
Tone 15 
Tone 5  
Tone 45  
Tone 5 
Tone 5  
Tone 45  
Tone 45  
Tone 17  
Tone 27  
Tone 5  
Tone 5  
Tone 5  
Tone 5  
Tone 34 
Tone 37 
Tone 37 
Tone 5 
Tone 37 
 

 

 

 

Tone Selection

 

– To select the required first stage tone set the tone switches 1 to 6 (see 

Fig 2) to the tone setting shown in the table below. The table also shows which 2

nd

 and 3

rd

 

stage tones are available for use with the selected first stage tone if more than one tone 
output stage is required. 

Reviews: