E2S IS-D105 Instruction Manual Download Page 1

 

 

_______________________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)20 8743 8880 

                                                                                                                                                             www.e2s.com             Fax: +44 (0)20 8740 4200 
Document No. D187-00-001-IS      Issue 3                 13-01-20                       

Sheet 1 of  5

 

INSTRUCTION MANUAL 

IS-D105 

Intrinsically Safe Sounder

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1)  Introduction 

 

The IS-D105 is an ATEX and IECEx certified intrinsically safe 

sounder  which  produces  a  loud  warning  signal  in  a 

hazardous  area.  Forty-nine  first  stage  alarm  sounds  can  be 

selected by internal switches and each one can be externally 

changed  to  a  second  or  third  stage  alarm  sound.  The 

sounder may be used in all gas groups IIA, IIB and IIC. An IS-

DL105  intrinsically  safe  combined  sounder  and  beacon  is 

also available.

 

 

2)  Ratings and Markings

 

 

2.1 ATEX/IECEx certification 
 

The IS-D105 sounder complies with the following standards:-  
 
EN IEC 60079-0:2018 / IEC60079-0:2017 
EN60079-11:2012 / IEC60079-11:2011 
 
 
 

 

 
The  EC-Type  Examination  Certificate  SIRA  04ATEX2301X 
has  been  issued  by  the  Notified  Body  Sira.  This  confirms 
compliance  with  the  European  ATEX  Directive  94/9/EC  for 
Group II, Category 1 G equipment.  The sounder carries the 
Community Mark and subject to local codes of practice, may 
be installed in any of the EEA member countries. The product 
has also been approved to the IECEx scheme, Certificate no. 
IECEx  SIR04.0038X.  This  instruction  sheet  describes 
installations  which  conform  to  EN60079-14:2008/IEC60079-
14:2007  Electrical  Installation  in  Hazardous  Areas.  When 
designing  systems  for  installation  outside  the  UK,  the  local 
Code of Practice should be consulted. 
 
 

 
The certification marking is as follows: 
 
1) 

The  certificate  number  has  an  ‘X’  suffix,  which 
indicates  that  the  certificate  contains  one  or  more 
special  conditions  for  safe  use.  Those  installing  or 
inspecting the equipment should refer to this section 
of the certificate. 

2) 

The equipment has not been assessed as a safety-
related  device  (as  referred  to  by  Directive  94/9/EC 
Annex II, clause 1.5). 

3) 

Installation of this equipment shall be carried out by 
suitably-trained personnel in accordance with the 
applicable code of practice. 

4) 

Repair of this equipment shall only be carried out by 
the manufacturer or in accordance with the 
applicable code of practice. 

5) 

The certification of this equipment relies on the 
following materials used in its construction: 

 

 

Enclosure: Aluminium Pressure Die Cast Body LM6 

 

Sealing of Enclosure & Mechanism: ‘O’ Ring

 

 

 

 

If the equipment is likely to come into contact with 
aggressive substances, then it is the responsibility of 
the user to take suitable precautions that prevent it 
from being adversely affected, thus ensuring that the 
type of protection is not compromised. 

 

“Aggressive substances” - e.g. acidic liquids or 
gases that may attack metals, or solvents that may 
affect polymeric materials. 

 

“Suitable precautions” - e.g. regular checks as part 
of routine inspections or establishing from the 
material’s data sheet that it is resistant to specific 
chemicals. 

 

2.2  Zones, Gas Groups and Temperature Classification 

 

The  IS-D105  sounder  has  been  certified  Ex  ia  IIC  T4  Ga. 

When  connected  to  an  approved  system  it  may  be  installed 

in: 

 

 

Zone 0 

explosive gas air mixture 

 

continuously present. 

 

Zone 1 

explosive  gas  air  mixture  likely  to  occur  in 

normal operation. 

 

Zone 2 

explosive  gas  air  mixture  not  likely  to  occur, 

and if it does, it will only exist for a short time. 

 

Be used with gases in groups: 

 

 

 

Group IIA  propane 

 

Group IIB  ethylene 

 

Group IIC  hydrogen 

 

Having a temperature classification of: 

 

T1 

450ºC 

T2 

300ºC 

T3 

200ºC 

T4 

135ºC 

The IS-D105 sounder is CE marked for 

compliance with the European 

Explosive Atmospheres Directive 

94/9/EC and the European EMC 

Directive 89/336/EEC 

II 1G     Ex ia IIC T4 Ga (-40ºC <= Ta <= +60ºC) 