E2S E2xL15F Instruction Manual Download Page 6

warning signals

2S

Ex N

EUROPEAN SAFETY SYSTEMS LTD

IMPRESS HOUSE

MANSELL ROAD

ACTON

LONDON W3 7QH

WWW.E2S.COM

C

THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE 

MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND 

IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY 

SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY 

BE DISCLOSED, LOANED, COPIED OR USED FOR 

MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR 

WRITTEN CONSENT.

EUROPEAN SAFETY SYSTEMS LTD.

AS PER LATEST DATE OF ISSUE SHOWN ABOVE

DRAWING TO BS8888:2000

GEOMETRIC TOLERANCES TO ISO1101:1983

LINEAR DIMENSIONAL TOLS

ANGULAR DIMENSIONAL TOLS

STANDARDS

MOD No.

REASON - INITIAL - DATE

ISSUE

DATE

APPROVED

CHECKED

DATE

DATE

DRAWN

WEIGHT (Kg)

SURFACE FINISH

MATERIAL

ALTERNATIVE MATERIAL

SHEET

SCALE

TITLE

A3

IF IN DOUBT, ASK - 

DO NOT SCALE

ALL DIMENSIONS IN MM

DRAWING NUMBER

A

B

C

D

E

F

G

10

9

G

F

E

7

8

6

5

D

C

1

3

4

2

A

B

D209-06-101

R.S.RAIT

R.N.POTTS

R.N.POTTS

05/08/2020

OF

E2xL15, E2xL25  

LOUDSPEAKER WIRING DIAGRAMS

INTRODUCTION

RSR - 05/08/2020

NTS 1

2

A

05/08/2020

05/08/2020

7.5W
7.5W

3W

3W

1W

1W

C
C

1W OUT

3W IN

3W OUT

7.5W IN

15W

15W

E2XL15V070 / E2XL15V100 LINE-IN UNITS 70V / 100V
Line Monitoring

E2XL25V070 / E2XL25V100 LINE-IN UNITS 70V / 100V
Line Monitoring

OPTIONAL LINE MONITORING RESISTOR, CUSTOMER SUPPLIED,  
REQUIRED MINIMUM VALUES:

R

1

70V LINE-IN: 1KΩ MIN, 2W MIN OR 3K9Ω MIN, 0.5W MIN

100V LINE-IN: 3.9KΩ MIN, 2W MIN OR 15KΩ MIN, 0.5W MIN

1W IN

7.5W OUT

R

1

15W IN

15W OUT

COMMON
COMMON

12.5W
12.5W

6W

6W

2W

2W

C
C

2W OUT

6W IN

6W OUT

12.5W IN

25W

25W

2W IN

12.5W OUT

25W IN

25W OUT

COMMON
COMMON

R

1

FORMAT UPDATED

DH - 17/05/2022

B

Summary of Contents for E2xL15F

Page 1: ... 3 Rating Marking Information 3 1 ATEX IECEx UKEx certification The E2xL15 and E2xL25 loudspeakers comply with the following standards Standards EN IEC 60079 0 2018 IEC60079 0 2017 Ed 7 Explosive Atmospheres Equipment General Requirements EN IEC 60079 7 2015 A1 2018 IEC 60079 7 2018 Ed 5 1 Explosive Atmospheres Equipment Protection by Increased Safety e EN 60079 31 2014 IEC 60079 31 2013 Ed 2 Expl...

Page 2: ... C Zone 22 AEx tc IIIC 100 C Dc Ta 20 C to 55 C Installation must be carried out in compliance with the National Electric Code CEC Class Zone ratings Canada Standards CAN CSA C22 2 No 60079 0 Ed 4 02 2019 Explosive Atmospheres Part 0 Equipment General Requirements CAN CSA C22 2 No 60079 7 Ed 2 Explosive Atmospheres Equipment Protection by Increased Safety e CAN CSA C22 2 No 60079 31 Ed 2 Explosive...

Page 3: ...32 End user shall adhere to the manufacturer s installation and instruction when performing housekeeping to avoid the potential for hazardous electrostatic charges during cleaning by using a damp cloth To maintain the ingress protection rating and mode of protection the cable entries must be fitted with suitably rated certified cable entry and or blanking devices during installation Equipment with...

Page 4: ...les and cable glands must be used as per table below Ambient Temp 40ºC 45ºC 50ºC 55ºC Min Rating of cables and cable glands 90ºC 95ºC 100ºC 105ºC If a high IP Ingress Protection rating is required then a suitable sealing washer must be fitted under the cable glands or blanking plugs For use in explosive dust atmospheres a minimum ingress protection rating of IP6X must be maintained For use in expl...

Page 5: ...ng its leads as short as possible a spacing of at least 1 16 1 58mm must be provided through air and over surfaces between uninsulated live parts 10 Low Impedance Wiring 10 1 L15 Low Impedance A 4 way terminal block is provided on the Low Impedance Loudspeakers There are 2 off Common and 2 off 15W 25W terminals in total For further detail refer to schematic document D209 06 101 Fig 8 L15 Low Imped...

Page 6: ...CE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D209 06 101 R S RAIT R N POTTS R N POTTS 05 08 2020 OF E2xL15 E2xL25 LOUDSPEAKER WIRING DIAGRAMS INTRODUCTION RSR 05 08 2020 NTS 1 2 A 05 08 2020 05 08 2020 7 5W 7 5W 3W 3W 1W 1W C C 1W OUT 3W IN 3W OUT 7 5W IN 15W 15W E2XL15...

Page 7: ...ES TO ISO1101 1983 LINEAR DIMENSIONAL TOLS ANGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D209 06 101 R S RAIT R N POTTS R N POTTS 05 08 2020 OF E2xL15...

Page 8: ...y Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 3G Ex ec IIC T4 T3 T2 Gc II 3D Ex tc IIIC 85 C 120 C Dc IP6X Dust Protection to EN60079 0 EN60079 31 Standards applied EN IEC 60079 0 2018 EN IEC 60079 7 2015 A1 2018 EN 60079 31 2014 Directive 2014 30 EU Electromagnetic Compatibility Directive EMC Standards applied EN 61000 6 1 2007 EN 61000 6 2 2005 EN 6...

Page 9: ...te and Place of Issue London 22 08 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives regulations and standards This Declaration is issued under the sole responsibility of the ma...

Page 10: ...ion Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 3G Ex ec IIC T4 T3 T2 Gc II 3D Ex tc IIIC 85 C 120 C Dc IP6X Dust Protection to EN60079 0 EN60079 31 Standards applied EN IEC 60079 0 2018 EN IEC 60079 7 2015 A1 2018 EN 60079 31 2014 Directive 2014 30 EU Electromagnetic Compatibility Directive EMC Standards applied EN 61000 6 1 2007 EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 ...

Page 11: ... Place of Issue London 22 08 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives regulations and standards This Declaration is issued under the sole responsibility of the manufa...

Reviews: