15W    COM 

25W    COM 

9.2 

L25 PCBA Terminals 

 
 

 

 

 

 

Fig. 6 L25 Line in Terminals 

 
 

9.3 

Line Monitoring (Line in Units Only) 

 
On E2xL15 & E2xL25 loudspeakers, DC line monitoring can 
be used if required. All Line in Loudspeakers have a blocking 
diode fitted in their supply input lines. It should be noted that 
each  loudspeaker  has  a  1M  ohm  bleed  resistor  connected 
across  the  blocking  capacitor  and  this  should  be  taken  into 
account  when  selecting  the  value  of  the  end  of  line 
monitoring resistance. The end of line monitoring resistor can 
be connected  across  the  terminals on the  end of line  unit. If 
an  end  of  line  resistor  is  used  it  must  have  the  following 
values: 
 

 

Min. Resistance 

Min. Power 

70V 

Line 

3.9KΩ 

0.5W 

1KΩ 

2W 

100V 

Line 

15KΩ 

0.5W 

3.9KΩ 

2W 

 
The resistor must be connected directly across the terminals. 
Whilst keeping its leads as short as possible, a spacing of at 
least 1/16” (1.58mm) must be provided through air and over 
surfaces between uninsulated live parts. 
 

10. Low Impedance Wiring 

 

10.1 

L15 Low Impedance 

 

A  4-way  terminal  block  is  provided  on  the  Low  Impedance 
Loudspeakers. There are 2-off Common and 2-off 15W/25W 
terminals in total. 
 
For further detail, refer to schematic document D209-06-101 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

 

 
 
 
 
 
 
 
 
 
 

Fig. 8 L15 Low Impedance Terminals 

 

10.2 

L25 Low Impedance 

 

 
 

 

 

 

Fig. 10 L25 Low Impedance Terminals 

 

11. Maintenance, Overhaul & Repair 
 

Maintenance,  repair  and  overhaul  of  the  equipment  should 
only  be  carried  out  by  suitably  qualified  personnel  in 
accordance with the current relevant standards: 

 

EN60079-19 
IEC60079-19 

Explosive atmospheres - Equipment repair, 
overhaul and reclamation 

 

EN 60079-17 
IEC60079-17 

Explosive atmospheres - Electrical 
installations inspection and maintenance 

 

To  avoid  a  possible  ELECTROSTACTIC  CHARGE  the  unit 
must only be cleaned with a damp cloth. 

 

Units must  not  be  opened  while an  explosive  atmosphere  is 
present. 

 

If  opening  the  unit  during  maintenance  operations  a  clean 
environment must be maintained and any dust layer removed 
prior to opening the unit. 

 

 

 
 
 
 
 

 

2W  6W  12.5W  25W  C 

Summary of Contents for E2xL15F

Page 1: ... 3 Rating Marking Information 3 1 ATEX IECEx UKEx certification The E2xL15 and E2xL25 loudspeakers comply with the following standards Standards EN IEC 60079 0 2018 IEC60079 0 2017 Ed 7 Explosive Atmospheres Equipment General Requirements EN IEC 60079 7 2015 A1 2018 IEC 60079 7 2018 Ed 5 1 Explosive Atmospheres Equipment Protection by Increased Safety e EN 60079 31 2014 IEC 60079 31 2013 Ed 2 Expl...

Page 2: ... C Zone 22 AEx tc IIIC 100 C Dc Ta 20 C to 55 C Installation must be carried out in compliance with the National Electric Code CEC Class Zone ratings Canada Standards CAN CSA C22 2 No 60079 0 Ed 4 02 2019 Explosive Atmospheres Part 0 Equipment General Requirements CAN CSA C22 2 No 60079 7 Ed 2 Explosive Atmospheres Equipment Protection by Increased Safety e CAN CSA C22 2 No 60079 31 Ed 2 Explosive...

Page 3: ...32 End user shall adhere to the manufacturer s installation and instruction when performing housekeeping to avoid the potential for hazardous electrostatic charges during cleaning by using a damp cloth To maintain the ingress protection rating and mode of protection the cable entries must be fitted with suitably rated certified cable entry and or blanking devices during installation Equipment with...

Page 4: ...les and cable glands must be used as per table below Ambient Temp 40ºC 45ºC 50ºC 55ºC Min Rating of cables and cable glands 90ºC 95ºC 100ºC 105ºC If a high IP Ingress Protection rating is required then a suitable sealing washer must be fitted under the cable glands or blanking plugs For use in explosive dust atmospheres a minimum ingress protection rating of IP6X must be maintained For use in expl...

Page 5: ...ng its leads as short as possible a spacing of at least 1 16 1 58mm must be provided through air and over surfaces between uninsulated live parts 10 Low Impedance Wiring 10 1 L15 Low Impedance A 4 way terminal block is provided on the Low Impedance Loudspeakers There are 2 off Common and 2 off 15W 25W terminals in total For further detail refer to schematic document D209 06 101 Fig 8 L15 Low Imped...

Page 6: ...CE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D209 06 101 R S RAIT R N POTTS R N POTTS 05 08 2020 OF E2xL15 E2xL25 LOUDSPEAKER WIRING DIAGRAMS INTRODUCTION RSR 05 08 2020 NTS 1 2 A 05 08 2020 05 08 2020 7 5W 7 5W 3W 3W 1W 1W C C 1W OUT 3W IN 3W OUT 7 5W IN 15W 15W E2XL15...

Page 7: ...ES TO ISO1101 1983 LINEAR DIMENSIONAL TOLS ANGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D209 06 101 R S RAIT R N POTTS R N POTTS 05 08 2020 OF E2xL15...

Page 8: ...y Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 3G Ex ec IIC T4 T3 T2 Gc II 3D Ex tc IIIC 85 C 120 C Dc IP6X Dust Protection to EN60079 0 EN60079 31 Standards applied EN IEC 60079 0 2018 EN IEC 60079 7 2015 A1 2018 EN 60079 31 2014 Directive 2014 30 EU Electromagnetic Compatibility Directive EMC Standards applied EN 61000 6 1 2007 EN 61000 6 2 2005 EN 6...

Page 9: ...te and Place of Issue London 22 08 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives regulations and standards This Declaration is issued under the sole responsibility of the ma...

Page 10: ...ion Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 3G Ex ec IIC T4 T3 T2 Gc II 3D Ex tc IIIC 85 C 120 C Dc IP6X Dust Protection to EN60079 0 EN60079 31 Standards applied EN IEC 60079 0 2018 EN IEC 60079 7 2015 A1 2018 EN 60079 31 2014 Directive 2014 30 EU Electromagnetic Compatibility Directive EMC Standards applied EN 61000 6 1 2007 EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 ...

Page 11: ... Place of Issue London 22 08 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives regulations and standards This Declaration is issued under the sole responsibility of the manufa...

Reviews: