background image

 

 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D190-00-051-IS

 

Issue 1

 

03-02-2022

 

 

Sheet 2 of 7

 

 

3) 

Marking & Rating Information 

 
The  D1xS1  Alarm  Horns  comply  with  the  following  standards  for 
hazardous locations:  
  

3.1 

Class/Division Ratings for US & Canada 

 

Standards 

Class I UL 1203 & CSA C22.2 No 25-1966 

Class Division Ratings for US (NEC) 

Model No: 

Rating 

D1xS1-DC024-D / 
D1xS1-AC230-D 

 

Class II Div 1 FG T6 Ta -55°C to +70°C 
Class III Div 1           Ta -55°C to +70°C 

Class Division Ratings for Canada (CEC)

 

Model No:

 

Rating

 

D1xS1-DC024-D  

Class II Div 1 FG T6 Ta -55°C to +70°C 
Class III Div 1           Ta -55°C to +70°C 

D1xS1-AC230-D 

Class II Div 1 FG T6 Ta -55°C to +40°C 
Class III Div 1           Ta -55°C to +40°C 

Class Zone Ratings for US (NEC)

 

Model No:

 

Rating

 

D1xS1-DC024-D / 
D1xS1-AC230-D 

Class II Zone 20 IIIB T6 Ta -55°C to +70°C 
 

Class Zone Ratings for Canada (CEC)

 

Model No:

 

Rating

 

D1xS1-DC024-D  

Class II Zone 20 IIIB T6 Ta -55°C to +70°C 

D1xS1-AC230-D 

Class II Zone 20 IIIB T6 Ta -55°C to +40°C 

Installation must be carried out in compliance with the National 
Electric Code / Canadian Electric Code 

Ambient Temperature Range

 

-55°C to +70°C (-67°F to +158°F) 

IP Rating

 

IP66 to EN60529 
4 / 4X / 3R / 13 to UL50E / NEMA250 

 

 

4) 

Special Conditions for Safe Use 

 
To access the Ex d chamber, loosen the M4 grub screw on the 
sounder cover. Open the enclosure by turning the sounder cover 
counterclockwise and remove the cover. 
 
Electrical connections are to be made into the terminal blocks on the 
PCBA, using solid wire 0.5-4mm2 / AWG 20-12 or stranded wire, 
sizes 0.5-2.5mm2 / AWG 24-14. Wire insulation needs to be stripped 
8mm. Wires may be fitted securely with crimped ferrules. Terminal 
screws need to be tightened down with a tightening torque of 0.45 
Nm / 3.5 Lb-in. 
 
Internal earthing connections should be made to the Internal Earth 
terminal in the base of the housing using a ring crimp terminal to 
secure the earth conductor under the earth clamp. The earth 
conductor should be at least equal in size and rating to the incoming 
power conductors but at least a mini mum of 0.82mm2 / 18AWG in 
size. 
External earthing connections should be made to the M5 earth stud, 
using a ring crimp terminal to secure the earth 
conductor to the earth stud. The external earth conductor should be 
at least 4mm2 in size. 
 
On completion of the installation the flameproof threaded joint should 
be inspected to ensure that they are clean and that they have not 
been damaged during installation.  
 

Ensure the O-ring seal is in place and undamaged. 
 
When fitting the flameproof cover ensure the thread is engaged 
correctly. Fully tighten the cover all the way, ensure no gap is visible 
between the cover and base of the sounder enclosure. 
 
The cable entries have two M20 x 1.5 

– 6H entry thread and a single 

½” NPT thread. If the installation is made using cable glands, only 
suitably rated and certified cable glands must be used. They must be 
suitable for the type of cable being used and also meet the 
requirements of the current installation standards EN 60079-14 / 
IEC60079-14. 
 
If the installation is made using conduit, openings must have a 
sealing fitting connected within 18” of enclosure. 
 
Any unused cable entries must be closed with suitably rated and 
certified blanking plugs. 
 
The plastic horn is not anti-static and the metallic enclosure has a 
non-conductive coating. These may generate an ignition-capable 
level of electrostatic charges under certain extreme conditions. The 
user should ensure that the equipment is not installed in a location 
where it may be subjected to external conditions that might cause a 
build-up of electrostatic charges on non-conducting surfaces. 
 
Repair  of  the  flameproof  threaded  joints  and  cemented  joints  is  not 
permitted. 
 
The Equipment must not be installed with the horn facing upwards 
of horizontal. 
 
 
 
 

 

  
Only  the  explosionproof  cover  is  to  be  used  for  access  to  the 
enclosure for installation, service and maintenance. 
    
 

 

Summary of Contents for D1xS1FAC230-D

Page 1: ...KEEP TIGHTLY CLOSED WHEN IN OPERATION WARNING FIT SEALING FITTING IN CONDUIT RUNS WITHIN 18 INCHES FROM ENCLOSURE EQUIPMENT MUST NOT BE INSTALLED WITH THE HORN FACING UPWARDS OF HORIZONTAL DO NOT OPE...

Page 2: ...housing using a ring crimp terminal to secure the earth conductor under the earth clamp The earth conductor should be at least equal in size and rating to the incoming power conductors but at least a...

Page 3: ...threads in the process 6 Installation Requirements 6 1 Safe Installation Requirements Warning High voltage may be present risk of electric shock DO NOT open when energised disconnect power before open...

Page 4: ...range can be supplied with the following types of adapters M20 to NPT M20 to NPT M20 to M25 It is important to note that stopping plugs cannot be fitted onto adapters only directly onto the M20 entri...

Page 5: ...005 wiring options Config Voltage Configuration Description Features Product Option Identifier 1a DC Single Stage Configuration Line monitoring Positive Switching 1 1b DC Two Stage Configuration Commo...

Page 6: ...8 End of Line Resistor placement 8Custom DC Multi Stage End Of Line Monitoring An optional 12 way terminal module is available to enable up to four alarm stages to be activated from three DC voltage...

Page 7: ...Only End of Line Devices may be fitted between the ve ve terminals of the PCBA Please ensure that the device legs meet the wire size range stated for the connection terminals and are fitted correctly...

Page 8: ...0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 0 0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1...

Page 9: ...INE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120 MIN 2W MIN OR 1K MIN 0 5W MIN 28V MAX SYSTEM 470 MIN 2W MIN OR 2 4K MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Stage 1 ve IN Stage 1 ve OUT...

Page 10: ...n ve OUT Stage 1 ve OUT Stage 3 ve Stage 1 ve IN H2 H1 Stage 1 ve Stage 1 ve Stage 2 ve Stage 2 ve OF 2 3 R1 S2 S3 R1 S2 R2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120 MIN 2...

Page 11: ...er to Stage 2 ve Stage 2 ve Two Three Stage Voltage Free Activation Configuration Config 5 Customer Set H1 H2 to Negative Switching See Below Power ve ve Stage 1 Connect Stage 1 ve to Common ve Stage...

Page 12: ...5 R S RAIT B ISARD R N POTTS OF NTS 1 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED 1 Earth Earth Stage 2 Stage 3 Common Live IN Live OUT Neutral IN Neutral OUT Earth Stage 1 Stage 2 Common N N L L E...

Reviews: