European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                             www.e-2-s.com             Fax: +44 (0)208 740 4200 
Document No. IS 2446-76-P      Issue 1          25/02/13                                Sheet 3 of 6 

        Mod No: ACN0012

 

 

 

The  current  levels  shown  above  are  for  the  440Hz 
Continuous tone @ nominal input voltage. The 24V and 48V 
DC units and the 230V and 115V AC units have a switching 
voltage  regulator  circuit  and  therefore  the  input  current  level 
will  decrease  slightly  as  the  input  voltage  in  increased  and 
will increase slightly as the input voltage is reduced. The 12V 
units do not have a voltage regulator and therefore their input 
current will increase when the input voltage is increased. 
 
Beacon Section 
 
The input current to the beacon section will vary according to 
the  voltage  input  level.  The  current  levels  shown  above  are 
for  nominal  input  voltage.  The  12V,  24V  and  48V  DC  units 
have  a  converter circuit  and  therefore  the  input  current level 
will decrease slightly as the input voltage is increased and will 
increase slightly as the input voltage is reduced.  
 

9) 

 Cable Selection 

 

When selecting the cable size consideration must be given to 
the input current  that each unit  draws  (see  table  above),  the 
number of units on the line and the length of the cable runs. 
The cable size selected must have the necessary capacity to 
provide  the  input  current  to  all  of  the  units  connected  to  the 
line.  
 
SAFETY  WARNING:  If  the  unit  is  used  at  high  ambient 
temperatures,  i.e.  over  +40ºC,  then  the  cable  entry 
temperature  may  exceed  +70ºC  and  therefore  suitable  heat 
resisting  cables  must  be  used,  with  a  rated  service 
temperature of at least 110ºC. 
 

10) 

  Earthing

 

 

Both  AC  and  DC  units  must  be  connected  to  a  good  quality 
earth.  The  units  are  provided  with  internal  and  external 
earthing  terminals,  which  are  both,  located  on  the  beacon 
section of the unit (see figures 2 and 3).  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
When  using  the  external  earth  terminal  a  cable  crimp  lug 
must be used.  The cable lug should be located between the 
two  M5  stainless  steel  flat  washers.  The  M5  stainless  steel 
spring  washer  must  be  fixed  between  the  outer  flat  washer 
and the M5 stainless steel nut to ensure that the cable lug is 
secured against loosening and twisting. 
 
The  internal  earth  bonding  wire  ensures  that  a  good  quality 
earth is maintained between the sounder section casting and 
the beacon section casting. 
 

11) 

 Cable Glands

 

 

The  BExDCTS110-05D  unit  has  dual  cable  gland  entries 
which  have  an  M20  x  1.5  entry  thread  as  standard.  Only 
cable  gland

s  approved  for  Ex  ‘d’  applications  can  be  used, 

which  must be suitable  for  the  type  of  cable  being  used  and 
also  meet  the  requirements  of  the  Ex  ‘d’  flameproof 
installation standard EN 60079-14:2008 / IEC60079-14:2007. 
 
When  only  one  cable  entry  is  used  the  other  one  must  be 
closed with an Ex ‘d’ flameproof blanking plug, which must be 
suitably approved for the installation requirements.  
 
For combustible dust applications, the cable entry device and 
blanking  elements  shall  be  in  type  of  explosion  protection 
increased  safety  "e"  or  flameproof  enclosure  "d"  and  shall 
have an IP 6X rating according to EN60529:1992. 
 
SAFETY  WARNING:  If  the  unit  is  used  at  high  ambient 
temperatures,  i.e.  over  +40ºC,  then  the  cable  entry 
temperature  may  exceed  +70ºC  and  therefore  suitable  heat 
resisting  cable  glands  must  be  used,  with  a  rated  service 
temperature of at least 110ºC. 
 

12) 

 Cable Connections 

 

The combined sounder / beacon unit BExDCTS110-05D has 
separate  printed  circuit  boards  in  the  sounder  and  beacon 
sections.  The  terminals  for  the  incoming  power  supply  and 
telephone  signal  are  on  the  printed  circuit  board  in  the 
sounder section and the terminals for the beacon are on the 
printed  circuit  board  in  the  beacon  section  (see  figures  4&5 
and  6&7).  See  section  7  of  this  manual  for  access  to  the 
enclosure and the wiring diagrams at the end of this manual. 
 

The  incoming  cables  must  be  wired  to  the  terminals  on 
the  electronics  assembly  in  the  sounder  and  beacon 
section of the unit.  

 
POWER  CONNECTIONS  TO  SOUNDER  AND  BEACON 
SECTION 
 
The power input cable should enter the enclosure via one of 
the  M20  cable  entries  and  be  connected  to  the  following 
terminals. 
The power input (L) AC units or (+ve) DC units is connected 
to the telephone board (L/+) terminal (see figures 8 & 9) 
The power input (N) AC units or (-ve) DC units is connected 
to  the  beacon  board  (N)  AC  or  (-ve)  DC  units  terminal  (see 
figures 8 & 9) 
 
(L & N) AC units (+ve & 

–ve) DC units in the sounder section 

of the unit (see figures 6 and 7).  
 
The telephone signal cable should enter the enclosure via the 
other M20 entry and be connected to the telephone terminal 
in  the  sounder  section  of  the  units  (see  figures  6,7  and  8,9) 
and wiring diagrams on pages four and five. 
 
A  single  wire  with  a  cross  sectional  area  of  up  to  4mm²  can 
be  connected  to  each  terminal  way.  When  connecting  wires 
to the terminals great care should be taken to dress the wire 
so that when the beacon section is inserted into the chamber 
the  wires  do  not  exert  excess  pressure  on  the  terminal 
blocks.  This  is  particularly  important  when  using  cables  with 
large cross sectional areas such as 2.5mm² and above.  
 

 

Internal Bonding Wire Terminal 

 

Internal Earth Terminal 
 

2 off M20  
Cable Entries 

 

Figure 3 

Summary of Contents for BExDCTS110-05D

Page 1: ... DUST ATMOSPHERE IS PRESENT COVER BOLTS CLASS A4 80 USE HEAT RESISTING CABLES AND CABLEGLANDS Rated 110ºC AT AMB TEMPERATURES OVER 40ºC Year of Construction Serial No i e 10 1DCTS21000001 3 Type Approval Standards The units have an EC Type examination certificate issued by DEKRA and have been approved to the following standards EN60079 0 2006 IEC60079 0 2004 Ed4 General Requirements EN60079 1 2007...

Page 2: ...that these screws and their spring washers are kept in a safe place during installation On completion of the cable wiring installation the flameproof joints should be inspected to ensure that they are clean and that they have not been damaged during installation Also check that the earth bonding wire between the two casting sections is secure and the O ring seal is in place When replacing the beac...

Page 3: ...tries which have an M20 x 1 5 entry thread as standard Only cable glands approved for Ex d applications can be used which must be suitable for the type of cable being used and also meet the requirements of the Ex d flameproof installation standard EN 60079 14 2008 IEC60079 14 2007 When only one cable entry is used the other one must be closed with an Ex d flameproof blanking plug which must be sui...

Page 4: ...elephone pcb see figures 6 and 7 The Telephone Selection Table on page six shows the switch positions 1 4 for the country setting and switch 5 for the beacon continuous or pulse mode and switch 6 for the sounder continuous or pulse mode When making any changes to the country selection the unit needs to be de energised for a minimum of 2 minutes for the changes to take effect When pulse mode of ope...

Page 5: ... 1200 500Hz at 0 3Hz 1 1 1 0 0 9 Sawtooth 1200 500Hz at 1Hz 0 0 0 1 0 10 Alternating 2400 2900Hz at 2Hz 1 0 0 1 0 11 Intermittent 1000Hz at 0 5Hz General alarm 0 1 0 1 0 12 Alternating 800 1000Hz at 0 875Hz 1 1 0 1 0 13 Intermittent 2400Hz at 1Hz 0 0 1 1 0 14 Intermittent 800Hz 0 25s on 1s off 1 0 1 1 0 15 Continuous at 800Hz 0 1 1 1 0 16 Intermittent 660Hz 150mS on 150mS off 1 1 1 1 0 17 Alternat...

Page 6: ...D CONTINUOUS OR PULSE SELECTION TABLE Telephone Selection Settings DIP Switch Settings DIP Switch Settings Dialing Country Setting 1 2 3 4 5 6 Australia Ireland New Zealand Singapore South Africa UK 0 0 0 0 Belgium Canada Cyprus Hong Kong Spain Turkey USA 1 0 0 0 Czech Republic Finland France Germany Greece Italy Luxemburg Netherlands Norway Switzerland 0 1 0 0 Austria Iceland Portugal Sweden 1 1 ...

Reviews: