8)  Power Supply Selection 

 

It is important that a suitable power supply is used to run the 
equipment.  The  power  supply  selected  must  have  the 
necessary  capacity  to  provide  the  input  current  to  all  of  the 
units. 

 

The  following  table  shows  the  input  current  taken  by  the 
various  sounders  and  shows  the  maximum  voltage  at  which 
the sounders can be operated: 

 

The input current will vary according to the voltage input level 
and  the  frequency  of  the  tone  selected.  The  current  levels 
shown above are for the 440Hz Continuous tone @ nominal 
input voltage.  

 

9)  Selection of Cable. Cable Glands, Blanking 

Elements & Adapters

 

 

When  selecting  the  cable  size,  consideration  must  be  given 
to  the  input  current  that  each  unit  draws  (see  table  above), 
the  number  of  sounders  on  the  line  and  the  length  of  the 
cable runs. The cable size selected must have the necessary 
capacity  to  provide  the  input  current  to  all  of  the  sounders 
connected to the line.  

 

For  ambient  temperatures  over  +40ºC  the  cable  entry 
temperature  may  exceed  +70ºC  and  therefore  suitable  heat 
resisting cables and cable glands must be used, with a rated 
service temperature of at least 110ºC 

 

The dual cable gland entries have an M20 x 1.5 entry thread. 
To  maintain  the  ingress  protection  rating  and  mode  of 
protection, the cable entries must be fitted with suitably rated 
ATEX  /  IECEx  certified  cable  glands  and/or  suitably  rated 
ATEX  /  IECEx  certified  blanking  devices  during  installation 
according to EN / IEC60079-14. 

 

If  a  high  IP  (Ingress  Protection)  rating  is  required  then  a 
suitable sealing washer must be fitted under the cable glands 
or blanking plugs.  

 

For  use  in  explosive  dust  atmospheres,  a  minimum  ingress 
protection rating of IP6X must be maintained. 

 

The  BEx  sounder  range  can  be  supplied  with  the  following 
types of adapters: 

 

M20 to ½” NPT 
M20 to ¾” NPT 
M20 to M25 

 

It  is  important  to  note  that  stopping  plugs  cannot  be  fitted 
onto adapters, only directly onto the M20 entries. 
Any  other  adapters  used  must  be  suitably  rated and  ATEX  / 
IECEx certified adapters. 

 
 
 
 

10) Earthing 

 

Both  AC  and  DC  sounder  units  must  be  connected  to  an 
earth. The units are provided with internal and external earth 
terminals  which  are  both  located  on  the  terminal  chamber 
section of the unit. 

 

Fig. 3 Internal View of Cover 

 

When  using  the  internal  earth  terminal  ensure  that  the 
stainless steel M4 flat washer is between the incoming earth 
wire and the enclosure.  

 

Internal earthing connections should be made to the Internal 
Earth  terminal  in  the  base  of  the  housing  using  a  ring  crimp 
terminal to secure the earth conductor under the earth clamp. 
The  earth  conductor  should  be  at  least  equal  in  size  and 
rating to the incoming power conductors. 

 

External  earthing  connections  should  be  made  to  the  M5 
earth  stud,  using  a  ring  crimp  terminal  to  secure  the  earth 
conductor  to  the  earth  stud.  The  external  earth  conductor 
should be at least 4mm² in size. 

 

11) Cable Connections 

 

Electrical connections are to be made into the terminal blocks 
on  the  PCBA  located  in  the  flameproof  enclosure.  See 
section  7  of  this  manual  for  access  to  the  flameproof 
enclosure.  

 

Wires  having  a  cross  sectional  area  between  0.5  mm²  to 
2.5mm²  can  be  connected  to  each  terminal  way.  If  an  input 
and  output  wire  is  required  the  2-off  Live/Neutral  or  +/- 
terminals  can  be  used.  If  fitting  2-off  wires  to  one  terminal 
way  the  sum  of  the  2-off  wires  must  be  a  maximum  cross 
sectional area of 2.5mm². Strip wires to 8mm. Wires may also 
be fitted using ferrules. Terminal screws need to be tightened 
down  with  a  tightening  torque  of  0.45  Nm  /  5  Lb-in.  When 
connecting wires to the terminals great care should be taken 
to dress the wires so that when the cover is inserted into the 
chamber  the  wires  do  not  exert  excess  pressure  on  the 
terminal  blocks.  This  is  particularly  important  when  using 
cables with large cross sectional areas such as 2.5mm². 
 
 
 
 
 
 
 
 
 

Model No. 

Nominal I/P 

Voltage 

Input 

Current 

Max. I/P 

Volts 

BExS120DDC012 

12Vdc 

850mA 

15V 

BExS120DDC024 

24Vdc 

800mA 

30V 

BExS120DDC048 

48Vdc 

420mA 

58V 

BExS120DAC115 

115Vac 

180mA  

126V  

BExS120DAC230 

230Vac 

90mA 

253V 

External Earthing 

Internal 
Earthing 

Internal 
Bonding 
Wire 
Terminal 

2-off M20 
Cable 
Entries 

Summary of Contents for BE S120D Series

Page 1: ...C Certificate No KEMA 99ATEX6312X IECEx KEM 10 0003X The units can be installed in locations with the following conditions Area Classification Gas Zone 1 Explosive gas air mixture likely to occur in...

Page 2: ...and Mounting The location of the sounder should be made with due regard to the area over which the warning signal must be visible They should only be fixed to services that can carry the weight of the...

Page 3: ...o NPT M20 to M25 It is important to note that stopping plugs cannot be fitted onto adapters only directly onto the M20 entries Any other adapters used must be suitably rated and ATEX IECEx certified a...

Page 4: ...eration Simply connect the supply voltage to the L and N supply terminals see fig 4 12 2 2 AC Units Second Third Stage Tone Selection To select the second third and fourth stage tones on the BExS110 A...

Page 5: ...ve the facility to use either ve or ve switching to change the tone to the second and third stages Negative switching is the default setting For ve switching connect the two headers on the pcb to the...

Page 6: ...e set by adjusting the volume control potentiometer see Fig 9 For maximum output set the potentiometer fully clockwise BExS120D AC BExS120D DC Fig 9 Location of Volume Control Potentiometer 15 Mainten...

Page 7: ...1 0 Tone 31 Tone 1 12 Alternating 800 1000Hz at 0 875Hz 1 1 0 1 0 Tone 4 Tone 5 13 Intermittent 2400Hz at 1Hz 0 0 1 1 0 Tone 15 Tone 5 14 Intermittent 800Hz 0 25s on 1s off 1 0 1 1 0 Tone 4 Tone 5 15...

Page 8: ...7 112 8 113 1 116 7 119 2 119 8 112 9 112 3 3 500 1200Hz 0 3Hz 0 5 Sec Slow Whoop 114 5 115 9 119 8 119 9 114 8 113 5 113 9 115 7 119 5 119 7 114 7 113 1 9 1200 500Hz 1Hz DIN PFEER P T A P 114 5 115...

Reviews: