S1 - LED Flash Mode Settings (AC & DC)
The Flash Mode Dip Switch can be changed to set the desired
flash pattern
Flash Mode DIP Switch – Shown with 1-OFF, 2-ON, 3-OFF (0 1 0),
This denotes Flash mode 1Hz. For further flash modes refer to
table:
Switch
Flash Mode
0 0 0
Steady on
1 0 0
Blinking
0 1 0
Flashing 1Hz
*
1 1 0
Flashing 1.5Hz
*
0 0 1
Flashing - Double Strike
1 0 1
Flashing - Triple Strike
0 1 1
Flashing 2Hz
*
1 1 1
Flashing - Temporal
1 2 3
ON
•
All models are approved for use as Audible Signal and Visual Appliance
for use as General Signaling: UL464A & CSA C22.2 No 205-17
•
Type 4 / 4X / 3R / 13, IP66 independently tested to EN60529:1991
•
-
40°C to +66°C / -40°C to +151°F
General Signaling Canada:
AL100HDC: -40°C to +55°C / -40°F to +131°F
AL100HAC: -40°C to +40°C / -40°F to +104°F
•
To maintain Ingress Protection, cable entries must be fitted with suitably rated cable glands or stopping plugs
•
EOL Monitoring (DC Only): End of Line Devices may be fitted between the +ve & -ve terminals of the PCBA. Please ensure that the device
legs meet the wire size range stated for the connection terminals and are fitted correctly in order to avoid a short. Refer to the compatible
control panel specification for EOL device values and ratings
Model
Nominal
Voltage
Voltage Range
Nominal Operating Current*
Max Operating RMS
#
Beacon
Sounder
Beacon
Sounder
AL100HDC024
12V dc
10-14Vdc
79.5mA
17mA
168mA
125mA
24V dc
16-33Vdc
(Regulated)
87mA
33.5mA
183mA
AL100HDC048
48V dc
48-60Vdc
60mA
113mA
115mA
AL100HAC230
115V ac
48 - 260Vac
50/60Hz
34mA
25mA
42.5mA
166mA
230V ac
19mA
17mA
*Nominal Voltage, 1Hz Flash Pattern & Tone 12;
#
Worst-case input voltage and worst case flash pattern