INSTRUCTION & SERVICE MANUAL 
AL100H AlertAlight Combined Sounder LED Beacons 

 

Unit Type Code 

Nominal 

Voltage 

Voltage 

Range 

Nominal 

Sounder 

Current* 

Nominal 

Beacon 

Current* 

Nominal SPL  

Max SPL 

Average SPL 

AL100HDC024  

12 V dc  

10-14Vdc   

17mA 

79.5mA 

101.6dB(A) 

Tone 44 @ 1m 

110dB(A) 

Tone 4 @ 1m 

102.3dB(A) All 

tones @1m  

 24V dc  

33.5mA 

87mA 

16-33Vdc 

(Regulated)   

AL100HDC048 

48V dc  

113mA 

60mA 

48-60Vdc 

115V ac  

48 - 260Vac 

50/60Hz 

25mA 

34mA 

AL100HAC230  

230V ac 

17mA 

19mA 

  *Nominal current at nominal voltage, Tone 12 / 1Hz Flash Pattern 

0.4Nm

 

5mm

0.5   2.5mm 

• 

-

40°C to +66C (-40°F to 151°F) 

• 

Type 3R / 13 (IP66, Independently tested to EN60529:1991) 

• 

0.46Kg (1.01lb) 

• 

CE, All units UL Listed. 

Attention

: Installation must be carried out by an electrician in compliance with the latest codes and regulations. 

Attention

: L'installation doit être effectuée par un électricien conformément aux derniers codes et réglementations.  

Achtung

: Die Installation muss von einem Elektriker gemäß den neuesten Vorschriften und Bestimmungen durchgeführt werden.  

Attenzione

: L'installazione deve essere eseguita da un elettricista in conformità con i codici e le normative più recenti. 

Atención

: La instalación debe ser realizada por un electricista de acuerdo con los últimos códigos y regulaciones. 

Atenção: 

A instalação deve ser realizada por um eletricista de acordo com os códigos e regulamentos mais recentes. 

Внимание

: установка должна выполняться электриком в соответствии с последними нормами и правилами. 

Attention

: Disconnect from power source before installation or service to prevent electric shock  

Attention

: Débranchez-le de la source d'alimentation avant l'installation ou l'entretien pour éviter tout choc électrique. 

Achtung

: Vor Installation oder Wartung von der Stromquelle trennen, um einen Stromschlag zu vermeiden. 

Attenzione

: scollegare dall'alimentazione prima dell'installazione o dell'assistenza per evitare scosse elettriche. 

Atención

: desconéctelo de la fuente de alimentación antes de la instalación o el servicio para evitar descargas eléctricas. 

Atenção: 

Desconecte da fonte de alimentação antes da instalação ou serviço para evitar choque elétrico  

Внимание

: отключите от источника питания перед установкой или обслуживанием, чтобы предотвратить поражение электрическим током.

 

AC: 1.0 – 2.5mm

/ AWG18 – AWG12 

DC: 0.2 – 2.5mm

/ AWG24 – AWG12 

Summary of Contents for AlertAlight AL100H

Page 1: ...durchgeführt werden Attenzione L installazione deve essere eseguita da un elettricista in conformità con i codici e le normative più recenti Atención La instalación debe ser realizada por un electricista de acuerdo con los últimos códigos y regulaciones Atenção A instalação deve ser realizada por um eletricista de acordo com os códigos e regulamentos mais recentes Внимание установка должна выполня...

Page 2: ...Road Acton London W3 7QH sales e2s com e2s com D218 00 301 IS Issue 1 10 05 2021 Default S2 Tone 1 Default S1 Tone 44 ON 1 OFF 0 AC DC See D221 95 001 E DC S2 S1 N L E E S3 S2 N L AC See D218 06 205 See D218 06 201 S2 S3 S2 S1 L N E E N L S1 E ...

Page 3: ... House Mansell Road Acton London W3 7QH sales e2s com e2s com D218 00 301 IS Issue 1 10 05 2021 INSTRUCTION SERVICE MANUAL AL100H AlertAlight Combined Sounder LED Beacons 4x 1Nm ø20mm 98 3 86in 35 9 1 41in 35 9 1 41in 60 3 2 37in ...

Page 4: ... General Signaling Canada AL100HDC 40 C to 55 C 40 F to 131 F AL100HAC 40 C to 40 C 40 F to 104 F To maintain Ingress Protection cable entries must be fitted with suitably rated cable glands or stopping plugs EOL Monitoring DC Only End of Line Devices may be fitted between the ve ve terminals of the PCBA Please ensure that the device legs meet the wire size range stated for the connection terminal...

Page 5: ...Page left Intentionally blank ...

Page 6: ...n Factory finishes are not intended to be modified Attention Installation must be carried out by an electrician in compliance with the National Electrical Code NFPA 70 and the National Fire Alarm Signaling Code NFPA 72 or CSA 22 1 Canadian Electrical Code Part I Safety Standard for Electrical Installations Section 32 L installation doit exclusivement être réalisée par du personnel qualifié conform...

Page 7: ... 5 6 dB A 29 6 dB A 180 87 2 dB A 0 87 dB A 180 87 2 dB A 0 86 4 dB A S2 S3 S2 S1 AL100HDC024 Beacon PCBA 24VDC Mode Default Setting AL100HDC024 Beacon PCBA 12VDC Mode Customer to Set AL100HDC024 Sounder PCBA Jumper Setting Jumper Link 4 Jumper Link 5 Jumper Link 6 24VDC Mode Open Closed Open 12VDC Mode Closed Open Closed Flash Mode DIP switch E E Flash Mode DIP switch E E Jumper Link 6 Open Jumpe...

Page 8: ...TORY FITTED 2 R1 R1 S2 S3 R1 S2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Single Stage Configuration Config 1a Line Monitoring Stage 1 Apply Power to Stage 1 ve Stage 1 ve Two Stage Configuration Config 1b Common Positive Stage 1 Apply Power to Common ve S...

Page 9: ...STEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Single Stage Configuration Config 5a Line Monitoring Stage 1 Apply Power to Stage 1 ve Stage 1 ve Two Stage Configuration Config 5b Common Positive Stage 1 Apply Power to Common ve Stage 1 ve Stage 2 Apply Power to Common ve Stage 1 ve connect Stage 2 ve to Stage 1 ve Three Four Stage Configuration Config 5c Common Positive S...

Page 10: ...ET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D218 06 255 R S RAIT B ISARD R N POTTS OF SOUNDER LED WIRING DIAGRAMS NTS 1 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED WIRING LINKING BEACON SOUNDER FACTORY FITTED 2 Single Stage Configuration Config 1a Stage 1 Apply Power to Stage 1 Live Stage 1 Neutral Linked So...

Page 11: ...IONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D218 06 255 R S RAIT B ISARD R N POTTS OF NTS 2 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED WIRING LINKING BEACON SOUNDER FACTORY FITTED 2 Single Stage Configuration Config 2a Stage 1 Apply Power to Stage 1 Live Stage 1 Neutral Independent Sounder Beacon Activation Remove Link Wires Two Three Stage Sounder Configuration ...

Page 12: ... 0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 0 0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 1 0 1 1 1 0 1 0 1 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 1 0 1 1 0 0 1 1 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 1 0 1 1 0 1 0 1 1 1 0...

Reviews: