![E-TON VIPER 50 ST - SERVICE Service Manual Download Page 65](http://html1.mh-extra.com/html/e-ton/viper-50-st-service/viper-50-st-service_service-manual_3183138065.webp)
N.G.
CHECK FUEL FLOW TO CARBURETOR
O.K.
N.G.
SPARK TEST
WEEK OR NO SPARK
O.K.
TEST CYLINDER COMPRESSION
LOW COMPRESSION
O.K.
START THE ENGING
ENGINE DOES NOT FIRE
13.TROUBLESHOOTING
13.1 ENGINE DOES NOT START
13.4 LOSS POWER
13.2 POOR PERFORMANCE AT LOW AND IDLE SPEEDS 13.5 POOR HANDLING
13.3 POOR PERFORMANCE AT HIGH SPEED
13.1 ENGINE DOES NOT START
N.G.
POSSSIBLE REASON
★
No fuel In fuel tank
★
Clogged
float
valve
★
Clogged fuel tank cap breather hole
★
Clogged at fuel tube
★
Faulty spark plug
★
Fouled
spark
plug
★
Faulty
CDI
unit
★
Faulty
alternator
★
Faulty engine stop switch
★
Poorly connected ,broken or shorted wires
★
Broken or shorted ignition coil
★
Broken or shorted spark plug wire
★
Faulty pulse generator
★
Faulty
ignition
switch
★
Worn cylinder and piston rings
★
Damaged cylinder head gasket
ENGINE START BUT STOPS
★
Auto choke off or damaged
★
Auto choke power wire disconnected
★
Improperly adjusted air screw
★
Improperly
ignition
timing
★
Fuel / air mixture ratio is too lean
REMOVE AND INSPECT SPARK PLUG
WET PLUG
★
Carburetor
flooded
★
Improperly adjusted air screw
★
Fuel / air mixture ratio too rich
★
Auto choke stuck or damaged
★
Air
cleaner
dirty