9
TABLE 1
MODEL
NUMBER
PERFORMANCE
AIR
VOLUME
(CFM)
WATER
FLOW
(GPM)
DIMENSIONS
WEIGHT
(LBS)
WATER
HEATING
CAPACITY
COOLING
CAPACITY
COP
INLET
OUTLET
WATER
(FPT)
WIDTH
A
DEPTH
B
HEIGHT
C
D
kW
Btu/hr*
Btu/hr
Tons
WH-35
10.4
35,500
27,500
2.3
3.9
1040
7
1.0”
40”
26”
24.75”
7"
315
WH-55
17.0
58,000
45,500
3.8
4.1
1650
11
1.0”
47”
32”
28.5”
7"
405
WH-75
22.3
76,000
59,000
4.9
3.9
2150
15
1.5”
57”
32”
28.5”
7"
485
WH-100
28.7
98,000
78,000
6.5
4.2
3200
20
1.5”
63”
38”
42.5”
8"
660
WH-115
33.1
113,000 89,000
7.4
4.2
3200
23
1.5”
63”
38”
42.5”
8"
665
WH-140
41.6
142,000 110,000 9.2
3.9
3800
28
2.0”
63”
38”
42.5”
8"
725
WH-170
50.1
171,000 133,000 11.1
3.9
4900
34
2.0”
75”
46”
42.5”
8"
880
All dimensions are in inches. Weights are approximate shipping weights.
*Performance rating at 75ºF Entering Air Temperature and 55% Relative Humidity, 100ºF Entering Water Temperature.
** Blower design at 0.35” external static pressure.
All models standard 208/230 VAC, 3Ø, 60 Hz
Optional 460 VAC, 3Ø, 60 Hz
Optional 208/230 VAC, 1Ø, 60 Hz available on AWH-35 and AWH-55 only
Figure 2
PERFORMANCE SPECIFICATIONS
ROUGH IN DIMENSIONS
Summary of Contents for WH-35
Page 2: ......
Page 32: ...UNIT WIRING DIAGRAMS FUSE SIZES 208 230 VAC SINGLE PHASE 60 HZ 32 ...
Page 33: ...UNIT WIRING DIAGRAMS FUSE SIZES 208 230 VAC THREE PHASE 60 HZ WH 35 WH 55 and WH 75 only 33 ...
Page 34: ...UNIT WIRING DIAGRAMS FUSE SIZES 208 230 VAC THREE PHASE 60 HZ only 34 ...
Page 35: ...UNIT WIRING DIAGRAMS FUSE SIZES 460 VAC THREE PHASE 60 HZ 35 ...
Page 36: ...UNIT WIRING DIAGRAMS FUSE SIZES 460 VAC THREE PHASE 60 HZ only 36 ...