1
Prefix / Suffix Setup
Description:
To setup prefix and suffix parameters, changes will be effective after scanner ACK response.
Host Requirement
To setup prefix and suffix with a control characters use the following table:
[NUL] [SOH] [STX] [ETX] [EOT]
[ENQ] [ACK] [BEL] [BS] [HT]
[LF] [VT]
[FF]
[CR] [SO]
[SI]
[DLE] [DC1] [DC2] [DC3]
[DC4] [NAK] [SYN] [ETB] [CAN]
[EM] [SUB] [ESC] [FS]
[GS]
[RS] [US]
[DEL]
Example:
setting suffix with AbC, Carriage Return and Line Feed is
“SOH”<SUFFIX=AbC[CR][LF]>” EOT”
Then, the suffix value is added to the end of every good read, the control characters are sent in ASCII
characters.
Code Identifier
If the code identifier is enabled, then the standard AIM ID is added to the prefix. The AIM ID values are the
following:
Code39
]A
Code128 ]C
PDF417
]L
Magnetic ]M
The Code identifier is added to the end of the prefix value.
Scanner Response
ACK / NAK
Description
Field
Values allowed
Prefix
Set
PREFIX=
Add Code Identifier
Enable
PRECID=1
Disable *
PRECID=0
Suffix
Set
SUFFIX=
Add CR to Suffix
Enable
SUFFCR=1
Disable *
SUFFCR=0
Working With Engine