
13
Scanner Revisions
Description:
To request an Application 1, 2 or Hardware revision number.
Scanner Response
(APP1RV) ACK “N.NN.NN\r\n” / NAK
(APP1RV) ACK “N.NN.NN\r\n” / NAK
(HARDRV) ACK “N.NN.NN\r\n” / NAK
(SERIAL) ACK “NNNNNNNNNN\r\n” / NAK
N is an ASCII ‘0’ – ‘9’, All responses have a fixed length
Serial Number Read & Setup
Description:
The maximum length is 30 characters and no control character is allowed for a serial number.
Example:
‘SOH’<SERIAL:>‘EOT’
Scanner Response
ACK “XXXXXXXXXX…\r\n” / NAK
X is a printable ASCII, with variable length
Description:
When this option is enabled the data will be sent before the decoded data. The default
is a ‘disable’.
Scanner Response
ACK / NAK
Description
Field
Values allowed
Send Revision Number
Application 1
APP1RV:
Application 2
APP2RV:
Hardware
HARDRV:
Description
Field
Values allowed
Serial Number Read
SERIAL:
Add to stream
Enable
SERIEN=1
Disable *
SERIEN=0
Working With Engine