INSTALLATION
The unit has a sensing angle of 360°. It detects micro movement within a 6m
diameter (sitting zone) and can detect general movement up to 10m diameter at a
mounting height of 2.5 meters. (FIGURE 3)
FIGURE 3
SCHEMATIC
FIGURE 4
WIRING INSTRUCTION
(1) Switch off the power source or wall switch.
(2) Strip approximately 6-8mm insulating part of the wires from the terminal
block.
(3) The connection of all power cable is via a junction box. (Not supplied). The
power cable of “LS” and “N” is to be connected to LS and N of the light fitting.
(FIGURE 5)
FIGURE 5
(4) In order to install the sensor to the ceiling, drill a diameter of 65mm round
hole on the ceiling. Wedge the main body into the round hole directly.
(FIGURE 6)
FIGURE 6
IMPORTANT:
DO NOT PULL THE SPRINGS AWAY FROM THE BODY, THIS
WILL DAMAGE THE SPRING TENSION AND RENDER THE
WARRANTY INVALID.
OPTIONAL
65