background image

ELBCam

 

1

   -   Technical Documentation 

10.04.2007                     © E.L.B. Ex-Geräte Bachmann GmbH & Co. KG                       Page  6 

Appendix 

 

 

6 Liability 

 
The technical data specified for hazardous areas comply with the values 
certified in the European EEx approval. The user bears the sole responsibility 
of examining the equipment with regard to its suitability for the intended 
application and environmental conditions. E.L.B. Ex-Geräte GmbH  & Co. KG 
accepts no liability for any lack of suitability. 

 
 
 
 
 
 

EC Declaration of Conformity 

 
 
 
 
 
 
We hereby confirm the conformity of the equipment listed below with the directives of the 
Council of the European Community. The safety and installation instructions of the product 
documentation must be observed. 

Model: 

   USB 

Photo 

Camera 

ELBCam

 

1

 

 
Directive: 

  EMC 

Directive 

98/336/EC)* 

European Standards: 

EN 55022: 

1998, class B 

 

 

EN 55024: 

May 1999 

Directive: 

 

Low Voltage Directive 73/23/EC*) 

European Standards: 

EN 60950* 

 
Directive:  

94/9/EC*) 

European Standards: 

EN 60079-0:   

2004 

    E 

IEC 

60079-11: 

2004 

 

 

E.L.B. Ex-Geräte Bachmann GmbH + Co. KG,  
Postal address: An der Hartbrücke 8, 64625 Bensheim, Germany 
Phone: ++49 - 6251-637 36, Fax: ++49 - 6251-637 29, 
E-Mail: [email protected]
Manager: Steffen Bachmann 
 

 
 

Summary of Contents for ELBCam 1

Page 1: ...ELBCam 1 Technical Documentation 10 4 2007 ...

Page 2: ...d the DVD enclosed with the camera 1 Functional Description The intrinsically safe USB camera ELBCam 1 can take photos in a hazardous area Ex area potentially explosive atmosphere that can be edited immediately on a PC in a safe area via the USB port This does not require special software because the camera acts like an external hard disk drive and the photos are saved as JPG files Further advanta...

Page 3: ...data for hazardous areas use For additional information concerning operating and optical data refer to the manual of the Non Ex version enclosed with the camera The buzzer which is mentioned there has been removed however Taking photos Press the button on the back of the camera for 4 seconds Camera operation starts with one flash of the red lamp and the blue lamp flashing continuously If the camer...

Page 4: ... prohibited in hazardous areas Use of rechargeable batteries prohibited even in Non ex areas 2 alkaline cells size AAA Battery life during standby about 60 days Please remove the battery if you are not going to use the camera for a long time Technical Data 4 Operating Data Certificate no IBExU 06 ATEX 1021 Kind of protection II 2 G Ex ia IIC T4 Ambient temperature 20 C 50 C Supply 2 alkaline cells...

Page 5: ...tenance and cleaning of the units must only be performed by persons trained and authorized for this purpose insofar as they are familiar with the units If it can be assumed that safe operation is no longer possible switch off the unit and secure it against being used again It is prohibited for the operator or his staff to open the units in a way that is not described in this manual This may only b...

Page 6: ...of Conformity We hereby confirm the conformity of the equipment listed below with the directives of the Council of the European Community The safety and installation instructions of the product documentation must be observed Model USB Photo Camera ELBCam 1 Directive EMC Directive 98 336 EC European Standards EN 55022 1998 class B EN 55024 May 1999 Directive Low Voltage Directive 73 23 EC European ...

Page 7: ......

Page 8: ......

Reviews: