49
@IST01530EEJ 01 917 5A0 19 041 1
4.16.5 Flow Chart - Flue Gas Analysis
Select the fuel of the plant being tested.
Select the memory position under which the data
will be sav ed.
Select the test operator.
Select analysis mode.
Record the draft v alue.
Enter the Smoke values.
Setup the printing options.
When depressed for at least 2 seconds, turns the instrument on.
Adjusts the display contrast.
►Natural gas
L.P.G.
Diesel oil
#2 Fuel oil
Methane ▼
FUEL
►1:
2:
3:
OPERATOR ID
►Copies
Model
PRINT SETUP
full
1
►Mode
AUTOMATIC ANALYSIS
manual
►RefO
2
Auto:001 ▼
O
2
4.2
٪
CO
2
9.3
٪
Xair 1.25
Tf 190.1C
Ta 15.4C
∆T 74.7C
Eff 83.4
٪
Loss16.6
٪
CO 146p
NO 40p
SO
2
41p
NO
X
51p
WARNING
Insert the gas probe
in the chimney
AUTOZERO STARTED
WARNING
Starting combustion
analysis
AUTOZERO STARTED
►Mem.:001
Date:19/10/10
Time:18.22
Name: John Smith
RECALL MEMORY
1
2
3
D
S
A
Autozero: 25
Bat.:94
٪
Time:11.33
Date:09/18/03
BATTERY STATUS
►Mem.: 001
Fuel: Natural gas
Oper.:
Rep.: full
Mode: manual
MEMORY
►T outdoor: 20°C
WARNING
Use P+ positive
Inlet
DRAFT
►Smoke
Ambient CO,NO
Pressure
Tightness test
TC K temperature
▼
MEASUREMENTS
Autozero cycle end
Or
automatically, after 10 seconds.
Or
automatically, after 10 seconds.
4400-S
SN:00001 Ver:1.00
1
2
3
4
5
6
7
8
Summary of Contents for 4400
Page 1: ...4400 4400 Portable Combustion Gas Analyzers ...
Page 2: ......