e-ImageData Microfilm ScanPro 1000 Operator'S Manual Download Page 7

7

PC SYSTEM  REQUIREMENTS

Scanners are capable of inputting large amounts of data in relatively short periods of time.  This 
can push your computer system to the limits of its capabilities.  This means that you will need to 
evaluate the systems capabilities based on your intended scanning requirements.  Your evaluation 
of system capability will need to consider processing speed, computer memory (RAM), and hard 
disk storage.  Major factors to consider are scan type and resolution.  High resolution gray scale 
scans are much more demanding than Half-Tone scans for both processing speed and memory. 

Minimum System Requirements when used with Windows 2000 and XP:

Microfilm ScanPro 1000 

 

Recommended

2GHZ Pentium, or AMD 

 

Higher

Windows 2000, XP 

 

same

1GB Memory 

 

Higher

 

 

100 GB available hard disk space   

Higher

SVGA/XSVGA monitor (Minimum Screen Resolution Setting 1028 x 600 dpi) 

same

CD ROM reader 

 

same 

We have included a FireWire card with your purchase, we highly recommend that you use this 
card. The Microfilm Scanner connects to your computer FireWire port using the cable included 
with your Microfilm Scanner.

Summary of Contents for Microfilm ScanPro 1000

Page 1: ...1 Desktop Compact Film Scanner Operator s Guide Micro lm ScanProTM 1000 2 2007 ScanPro 1000 shown with optional combination che aperture card motorized 16 35mm roll lm carrier...

Page 2: ...9 Toolbar 10 SCAN to Drive 1 or Drive 2 10 Pre x 10 Format 10 Options 10 ROLL FILM CONTROL 10 SAVE AS 10 INCHES or MILLIMETERS 10 Fit to page size 11 Print Offset 12 GRAPHIC BUTTON CONTROLS 12 FILM T...

Page 3: ...ts returned to the manufacturer for warranty claims require a RETURN AU THORIZATION NUMBER RA number to be issued by the manufacturer s customer service The RA number must appear legibly on all return...

Page 4: ...INSERTS Fig 2 ACCESSORIES BOX remove before removing ScanPro Save all packing materials in case you need to move or ship your SCANNER INSERTS Fig 1 Fig 2 Fig 3 Fig 4 GRASP HERE FIRMLY E GRASP Scanner...

Page 5: ...e cable included with your Micro lm Scanner COMPUTER TO ScanPro1000 CABLE A FireWire IEEE 1394 cable is included with your scanner purchase This cable meets all of the speci cations for connecting you...

Page 6: ...to work with all types of micro lm OPTICAL ZOOM LENS Your ScanPro 1000 is equipped with a 7X to 54X ZOOM LENS system This lens is factory in stalled OPTIONAL ROLL FILM CARRIER If you have ordered a r...

Page 7: ...e scan type and resolution High resolution gray scale scans are much more demanding than Half Tone scans for both processing speed and memory Minimum System Requirements when used with Windows 2000 an...

Page 8: ...it is strongly recommended that you use only this cable Connect the AC DC Power Inverter to the Scanner and to your local AC power source shown below Fig 1 CONNECTING THE SCANNER TO THE COMPUTER Power...

Page 9: ...hown on the SETUP Window Fig 2 The SELECTED CONTROLS list speci es which controls are shown on the PowerScan TOOLBAR The AVAILABLE CONTROLS list speci es which control buttons are NOT shown on the Pow...

Page 10: ...a sequential number that is added to the PREFIX The PREFIX name can be set in the SETUP Window by typing a name in the eld titled Pre x Format Speci es the le format if the SAVE AS box is un checked...

Page 11: ...11 Print Offset Speci es the position a of scan on a printed page for example printing on a preprinted form...

Page 12: ...the vertical position for a PORTRAIT image and horizontal position for a LANDSCAPE image to take maximum advantage in capturing the image Look at the images on your micro lm and CLICK to SELECT the m...

Page 13: ...arged view of a portion of the image in the PowerScan Display To use the MAGNIFIER CLICK the MAGNIFIER BUTTON a portion of the image in the PowerScan Display To use the MAGNIFIER CLICK on the TOOL BAR...

Page 14: ...TYPE BUTTON to toggle between GRAY SCALE and HALF TONE scans HALF TONE scanning provides high quality small le size scans A decision should clarify the justices ruling upholding testing for athletes...

Page 15: ...the boundaries de ned by the Fit to Page settings in the Setup Window See Page 10 Use the the Fit to Page settings in the Setup Window See Page 10 and the Fit to Page settings in the Setup Window See...

Page 16: ...t printer preferences MOTORIZED ROLL FILM CON TROL CLICK and drag the button for low speed lm movement CLICK and hold the and buttons for fast speed lm movement speed doubles when the lm carrier is pu...

Page 17: ...OPEN the SETUP WINDOW 3 On the Toolbar section of the setup window in the Available Controls list click Save Settings so that this entry is highlighted 4 Click the Add button between the Available Con...

Page 18: ...he settings le was saved If you want to prohibit the user from changing your settings le or saving set tings of their own you will need to remove the Save Settings button from the toolbar PROCEDURE to...

Page 19: ...High resolution scan in one second SCANNING RESOLUTION Selectable 150 200 300 400 600 FILE FORMATS All common le formats including JPEG PDF TIFF TIFF LZW TIFF Group 4 PDF Multipage TIFF Multipage TIF...

Reviews: