7
Installation of VALVE:
Valves should be installed in respect of the gas-in pipe and water-in pipe prior to their connection to the water
heater. The hot water pipe should have a valve as well. After installation, testing should be carried out to
ensure there are no gas and water leakage.
3.4 The performance of vent pipe anti-block
device
Warning: the vent pipe anti-block device shall not be
put out of operation.
3.4.1 When installing the flue pipe anti-blocking
device, the connecting end of the device must be
connected with the igniter.
3.4.2 It may result in the leakage of combustion gas
to be threatened to people’s life when there is
untimely interference with the flue pipe anti-block
device.
3.4.3 When the flue pipe anti-blocking device cannot
work properly and needs replacing, it is
recommended to use the same device of the same
model provided by the manufacturer. Check whether
the device can work normally after replacing by
restarting the gas water heater.
3.4.4 In case of repeated shutdown of the appliance,
it will be necessary to contact our customer’s service
desk to take appropriate action to remedy the
discharge fault.
3.5 Repair and Maintenance
3.5.1
Water
heater shall be checked by
professional personnel every 6~12 months.
Check List:
1. Sealing of fuel gas route system; sealing of water
route system;
2. Clean filtration sieve on water inlet orifice to avoid
blockage;
3. Functions of all operating parts;
4. Flame
of
combustion;
5. Carbon accumulation of heat exchanger;
6. Proper air ventilation in room where water heater
is installed.
7. Gas
decompressor
3.5.2 Items checked and maintained by
professional personnel:
1. The
flexibility
of
water and gas linkage;
2. Clean carbon accumulation on buckling piece of
heat exchanger;
3. Grease gas valve and its core;
4. Carbon accumulation and oxidation coating on
ignition and induction needles;
8
4. INSTRUCTIONS FOR THE USER
4.1 Operation
4.1.1 START UP
Presentation
1. Insert two off # 1 size batteries in the battery box.
2. Open the valves of gas-in and water-in.
3. Inspect the gas source if there is leakage.
4. Inspect if there is any leakage on the hot water outlet and water inlet.
5. Turn on the hot water-out valve
4.1.2 IGNITION
When water pressure is above 0.5 bar, the ignition is
automatically initiated when you open the hot water valve.
For the newly installed water heater, the gas pipe might be
filled with air and cannot be ignited for the first time. Please
repeat on & off to exhaust the air until water heater is finally
ignited.
4.1.3 TEMPERATURE CONTROL
To adjust the water and gas until it’s comfortable.
When you use the water heater for first time, cold water
should not be turned up too much. Avoid a too low pressure
which can effect normal system operation. In some areas,
the water pressure may be too strong and thus water
cannot be heated. In this case, please turn down the
water-in valve.
The Winter/Summer option has an adjustment to winter or
summer mode (Operation of temperature control).
4.1.4 SHUT-OFF
1. To stop using the water heater, please shut off the gas valve or water-in valve;
2. Please drain water from the system if the temperature is below 0 °C or if the appliance is out of use and
dormant for an extended period of time.
4.1.5 RESTART
1. If the water heater stops during operation, close the hot water-out valve or water-in valve;
2. Open the closed hot water-out valve or water-in valve again;
3. Don’t touch the water from the water heater after restarting in order to avoid the scalding.
4.2 NOTES
ON
SAFETY