background image

™

 

Installation of VALVE:   

Valves should be installed in respect of the gas-in pipe and water-in pipe prior to their connection to the water 
heater. The hot water pipe should have a valve as well. After installation, testing should be carried out to 
ensure there are no gas and water leakage.   

 

 
 
 
 
 
 
 
 

3.4  The performance of vent pipe anti-block 

device  

Warning: the vent pipe anti-block device shall not be 
put out of operation. 
3.4.1 When installing the flue pipe anti-blocking 
device, the connecting end of the device must be 
connected with the igniter. 
3.4.2  It may result in the leakage of combustion gas 
to be threatened to people’s life when there is 
untimely interference with the flue pipe anti-block 
device. 
3.4.3  When the flue pipe anti-blocking device cannot 
work properly and needs replacing, it is 
recommended to use the same device of the same 
model provided by the manufacturer. Check whether 
the device can work normally after replacing by 
restarting the gas water heater. 
3.4.4  In case of repeated shutdown of the appliance, 
it will be necessary to contact our customer’s service 
desk to take appropriate action to remedy the 
discharge fault. 

3.5  Repair and Maintenance   

3.5.1 

Water

 heater shall be checked by 

professional personnel every 6~12 months. 

Check List: 

1.  Sealing of fuel gas route system; sealing of water 

route system;   

2.  Clean filtration sieve on water inlet orifice to avoid 

blockage; 

3.  Functions of all operating parts; 
4. Flame 

of 

combustion; 

5.  Carbon accumulation of heat exchanger; 
6.  Proper air ventilation in room where water heater 

is installed. 

7. Gas 

decompressor 

3.5.2 Items checked and maintained by 

professional personnel: 

1. The 

flexibility 

of 

water and gas linkage; 

2.  Clean carbon accumulation on buckling piece of 

heat exchanger; 

3.  Grease gas valve and its core; 
4.  Carbon accumulation and oxidation coating on 

ignition and induction needles; 
 

 

 
 
 
 
 
 
 
 
 
 

 

4. INSTRUCTIONS FOR THE USER 

4.1 Operation 

4.1.1 START UP  

Presentation  

1.  Insert two off # 1 size batteries in the battery box.   
2.  Open the valves of gas-in and water-in. 
3.  Inspect the gas source if there is leakage. 
4.  Inspect if there is any leakage on the hot water outlet and water inlet.   
5.  Turn on the hot water-out valve 

4.1.2 IGNITION 

When water pressure is above 0.5 bar, the ignition is 
automatically initiated when you open the hot water valve. 
For the newly installed water heater, the gas pipe might be 
filled with air and cannot be ignited for the first time. Please 
repeat on & off to exhaust the air until water heater is finally 
ignited. 

4.1.3 TEMPERATURE CONTROL  

To adjust the water and gas until it’s comfortable.   
When you use the water heater for first time, cold water 
should not be turned up too much. Avoid a too low pressure 
which can effect normal system operation. In some areas, 
the water pressure may be too strong and thus water 
cannot be heated. In this case, please turn down the 
water-in valve. 
The Winter/Summer option has an adjustment to winter or 
summer mode (Operation of temperature control). 

 

 

 

 

 

 

 

 

 

4.1.4 SHUT-OFF 

1.  To stop using the water heater, please shut off the gas valve or water-in valve; 
2.  Please drain water from the system if the temperature is below 0 °C or if the appliance is out of use and 

dormant for an extended period of time. 

4.1.5 RESTART 

1.  If the water heater stops during operation, close the hot water-out valve or water-in valve; 
2.  Open the closed hot water-out valve or water-in valve again; 
3.  Don’t touch the water from the water heater after restarting in order to avoid the scalding. 

4.2 NOTES 

ON 

SAFETY 

THIS APPLIANCE IS ADJUSTED TO OPERATE ON LPG ONLY. 

 

Summary of Contents for JSD 12 E

Page 1: ...RUCTIONS FOR THE INSTALLATION AND MAINTENANCE OF HOUSEHOLD INSTANTANEOUS INDOOR LPG GAS WATER HEATER TYPE B VENT PIPE Model No JSD 12 E LPGSASA Permit No _______ E Gas Systems The Proven Preferred Cho...

Page 2: ...n 4 3 2 Installation 4 3 3 How to install 5 3 4 The performance of vent pipe anti block device 7 3 5 Repair and Maintenance 7 4 INSTRUCTIONS FOR THE USER 8 4 1 Operation 8 4 2 NOTES ON SAFETY 8 5 INST...

Page 3: ...are a potential hazard source To safeguard the environment all packaging materials are environment friendly and recyclable Prior to connecting the appliance ensure that the rating plate data correspon...

Page 4: ...by qualified installer The manufacturer cannot be held responsible for any damage to persons or things deriving from an incorrect installation of the appliance 3 1 2 The safety and automatic adjustmen...

Page 5: ...135 2 mm An adapter can be used to help users to join the present flue pipe to other flues of different diameter HOW TO SET UP VENTILATION PASSAGE A Air in hole should be at a well ventilated positio...

Page 6: ...linkage 2 Clean carbon accumulation on buckling piece of heat exchanger 3 Grease gas valve and its core 4 Carbon accumulation and oxidation coating on ignition and induction needles 8 4 INSTRUCTIONS F...

Page 7: ...ease turn off the water inlet and press the reset button of the thermostat then turn them on again If there are repeated interruptions please call specialist for help 4 2 7 Avoid scald To resume using...

Page 8: ...ulation method of water temperature Enlarge gas volume reduce water volume Reduce gas volume enlarge water supply Improper position of water switch Turn water knob to hot water point Surroundings Air...

Page 9: ...ial number and type of problem you are having with it You will find the relative data printed on a label affixed behind the appliance and on the label affixed on the cover of this handbook With this i...

Page 10: ...The appliance was designed and manufactured in accordance to International Standards and is certified as a safe appliance by the Liquid Petroleum Gas Safety Association of South Africa...

Reviews: