![E+E Elektronik EE33 User Manual Download Page 19](http://html1.mh-extra.com/html/e-e-elektronik/ee33/ee33_user-manual_3074082019.webp)
19
EE33 Humidity / Temperature Sensor for High Humidity and Chemical Applications
6.2.2
Cable Gland / Plug Option E5
1 cable gland / 1 plug for RS232
RS232
Lumberg
RSC 5/7
M16x1.5
6.2.3 Plug Option E7
2 plugs for power supply / outputs and RS485 network
Lumberg
RSC 5/7
Y-splitter *
Lumberg
RKC 5/7
* Siemens 6ES7 194-1KA01-0XA0
power
analogue output
RS485
network
6.3 Alarm Module Connection Diagram (Option AM2)
Rel 1
Rel 2
6.4 Connection Configuration for Integrated Power Supply (Option AM3)
1
2
3
4
5
Euro-Standard
Plug for RS232 and
analogue output
(front view)
Plug for 100-240V
metal enclosure
(front view)
Plug for 100-240V
polycarbonate enclosure
(front view)
Description:
Connection assignment:
RxD / B-
5
TxD / A+
4
GND
3
OUT1
2
OUT2
1
Description:
Connection assignment:
Grounding (PE)
1
Phase (L1)
2
Neutral wire (N)
3
Description:
Connection assignment:
Phase (L1)
1
Neutral wire (N)
3
External diameter of supply cable: 10-12 mm (0.39-0.47”)
Maximum wire cross section for connecting cable: 1.5 mm² (AWG 16)
The protection of the supply cable against excess current and short-circuit must be designated
to a wire cross section of 0.8 mm² (AWG 18) (6 A fuse).
National regulations for installation must be observed!
Bottom and middle part of the metal enclosure must be grounded during operation!