background image

13

4. 

STARTING UP THE WIRELESS SYSTEM

There is no personal computer necessary to configure the EE241 – the desired setup is 

configured by E+E Elektronik in accordance with the ordering code.

Necessary steps to start up the system:

1)  Establish the power supply to the base station.

2)  Connect the sensing probe to the transmitter, either direct or with a sensor cable.

3)  Establish the power supply to the transmitter (4 Alkaline 1.5 V, AA batteries, in the scope  

  of supply).

  Remove the transportation insulation-strip in the battery compartment first, to activate 

 

  the transmitter.

4)  Establish the wireless connection:

  Press the push-button “Connect” for 3 seconds

  Immediately the base station switches to the ‘Connect-Mode’ and searches for active  

  transmitters – for 30 seconds. The LED next to the push-button lights up to indicate the 

 

  ‘Connect-Mode’ is active.

  Within these 30 seconds, the push-button “Connect” on the transmitter must be pressed  

  for 3 seconds to establish a connection. As soon as the base station recognizes the  

  wireless  signal  from  the  transmitter,  the  addresses  of  the  devices  are  automatically  

  exchanged and the wireless connection established.

5)  Checking the active wireless connection:

  -  Base station

    The  wireless  connection  is  active,  as  soon  as  the  measurement  data  is  available  

    (display, analogue output).

  -  Transmitter

    The  wireless  connection  is  active,  as  soon  as  in  the  display  the  symbol  ><  is  

    continuously illuminated (see chapter 3.2.3. Operating Components, under 3. Display).

6)  Alterations of the configuration of the transmitter:  

  The transmission interval is set at a default of 5 minutes. To increase the operating life  

  of the batteries the transmission interval can easily be altered with the rotary switch  

  “TIME”  in  accordance  with  the  interval-time  table,  see  chapter  3.2.3  Operating  

  Components, under 1. Rotary Switch “TIME”. 

4.1   “Point-to-Point” (EE241 with a single transmitter)

4.2   “Wireless Network” (EE242 with multiple transmitters)

In order to register the transmitter EE244 to the network through the router the following 

steps have to be taken:

a) Register the router:

Press the push-button “Connect” on the base station for 3 seconds.

Within 30 seconds, the push-button “Connect” on the router must be pressed for 3 seconds 

to establish a connection. As soon as the base station recognizes the wireless signal from 

the router, transmitters can be added and connected through the router.

b) Register transmitters to the network through the router:

Press the push-button “Connect” on the base station for 3 seconds.

Within 30 seconds, the push-button “Connect” on the transmitter must be pressed for 3 

seconds to establish a connection. As soon as the base station recognizes the wireless 

signal from the transmitter, the addresses of the devices are automatically exchanged and 

the wireless connection established.

4.3   Increasing the Transmission Distance with Routers

For the configuration of the EE242 a personal computer is needed (with admin authoriza

-

tion), to manage all transmitters and to configure the analogue outputs of the base station.

1)  Preparing the hardware:

 Attention: the base station can handle a maximum of 10 wireless signals (transmitter or  

 router). If more than 10 transmitters are needed, an extra router will extend the network  

 further (for details, see chapter 3.3. Router).

2)  Preparing the personal computer and software:

  No disk space is needed on the personal computer, because the EE242 is equipped  

  with a web server.

3)  Configuration of the wireless network:

  -  Connect  the  base  station  with  the  personal  computer  by  way  of  the  Ethernet  

    connection and adjust the network settings (see chapter, Configuration Software).

  -  Start the internet browser (Internet Explorer, Firefox, ….).

  -  Enter the default IP-address (//192.168.0.64) of the EE242 in the address line.

4)  Check the active wireless connection, see chapter 4.1 “Point–to-Point” (EE241with a 

 

  single transmitter), under 4).

5)  Changing the configuration settings of the transmitter and the base station, see chapter 

 

  Configuration Software.

Summary of Contents for EE240

Page 1: ...Manual Hardware and Software Series EE240 Wireless SENSOR FOR HUMIDITY TEMPERATURE CO2 BA_EE240_04_e technical data are subject to change 350118...

Page 2: ...allations If the equipment causes EMC disturbance during radio and television reception to be determined by switching the equipment on and off then it is recommended to take the following actions to e...

Page 3: ...M 13 4 1 Point to point EE241 with a single transmitter 13 4 2 Wireless network EE242 with multiple transmitters 13 4 3 Increasing the transmission distance with routers 13 5 CALIBRATION OF MEASUREMEN...

Page 4: ...ied out unconditionally If disregarded loss injury or damage may be inflicted to people and property In any case E E Elektronik Ges m bH cannot be hold responsible This symbol indicates attention The...

Page 5: ...SI Australia C Tick C Tick Japan R201WW07215215 R201WW08215142 FCC ID MCQ XBEEPRO2 part 15 of the FCC regulations IC 1846A XBEEPRO2 Canada accept FCC s audit report about the compliance with ICES 003...

Page 6: ...mission connection A maximum of 10 wireless connections per router base station see outline 2 1 3 2 1 2 Installation of a wireless system 2 1 3 Example for a wireless measurment setup Sensing probe TR...

Page 7: ...re and a humidity measurement The EE241 can communicate with only a single transmitter EE244 in between the two any desired number of routers can be installed to increase the transmission distance The...

Page 8: ...y1 Analog output 3 1 3 Operating Components Line 1 Serial number or name of the sensing probe Line 2 Measuring value of the selected sensing probe Line 3 Serial number or name of the sensing probe Lin...

Page 9: ...oints downwards 32 1 3 18 0 7 41 1 6 13 0 5 25 1 18 0 7 50 2 6 0 2 12 0 4 32 1 3 83 3 3 13 0 5 Installation of the housing 1 Drill the mounting holes according to the drill template see sketch There i...

Page 10: ...na cable and relocated Antenna cable see chapter 8 Spare parts Accessories Power supply Transmitter EE244 Axx is supplied with four Alkaline 1 5V AA batteries Transmitter EE244 Bxx will accept an exte...

Page 11: ...temperature value RH Unit for rel humidity RH 3 2 3 Operating components 1 Interval rotary switch TIME 2 Push button CONNECT To establish the initial connection between the base station and the trans...

Page 12: ...chapter 3 2 1 Installation of a transmitter 3 3 2 Electrical Connections The router is powered by an external power supply Pin assignment of the female socket see chapter 3 2 2 Electrical Connection...

Page 13: ...ess Network EE242 with multiple transmitters In order to register the transmitter EE244 to the network through the router the following steps have to be taken a Register the router Press the push butt...

Page 14: ...M 5 2 Customer s Calibration of the Humidity and Temperature Sensing Probes a Calibration software on the personal computer The calibration can be done by means of software on a personal computer see...

Page 15: ...r cap dirty Replace filter cap Wrong filter cap Replace with suitable filter cap for the application Transmitter failure Interrupted power supply or weak batteries Check the wiring of the power supply...

Page 16: ...ea level EE244 Transmitter Router Supply transmitter EE244 A battery 4x1 5V AA Battery lifetime 1 year with a measuring data transmission every 5 min for T RH External supply transmitter EE244 B 8 28V...

Page 17: ...ternet Explorer Mozilla Firefox and an Ethernet connection with the base station In order to setup a smooth configuration of the base station through the Ethernet network address admin authorization m...

Page 18: ...010333 or log both in to the same network Establish power to the EE242 Start the internet browser and enter the IP address of the base station http 192 168 0 64 Enter Username and Password the followi...

Page 19: ...functions properly Warn Alert OK Transmitters Line 1 number of active transmitters Line 2 number of active routers Line 3 total number of active transmitters and routers Base Station Line 1 model num...

Page 20: ...transmission The transmission interval can be setup with the rotary switch TIME see chapter 3 2 3 Operating Components under 1 Interval rotary switch TIME or direct from the web server The change to...

Page 21: ...serial number Measurand Indicates the active measurement parameter of the sensing probe temperature humidity CO2 Measured Value Last transmitted measured value More transmitter details will be listed...

Page 22: ...ied and paste from the transmitter list see chapter 12 2 1 Transmitter List with Ctrl C and Ctrl V Transmitter Port Select the transmitter port see chapter 12 2 2 Transmitter Details under TM Port to...

Page 23: ...desired measurement T RH Failsafe Value Output value which should be issued for a transmission error alarm Data Type Select data type Float Integer Factor Possible multiplication factor for the regis...

Page 24: ...24 Basic settings Modbus Main menu Management Modbus Basic settings for Modbus TCP for Modbus RTU...

Page 25: ...Mode before it can accept connection requests see chapter 4 Starting Up the Wireless System Cable Network IP address Assignment Manual static IP enter or change manually the IP address of the base st...

Page 26: ...fo epluse cn www epluse cn E E CHINA SHANGHAI Tel 86 21 61176129 info epluse cn www epluse cn E E GERMANY Tel 49 6172 13881 0 info epluse de www epluse de E E FRANCE Tel 33 4 7472 35 82 info epluse fr...

Reviews: