User Manual EE1900 Humidity Module for Climate Chambers

1  General

This user manual serves for ensuring proper handling and optimal functioning of the device. The user 

manual shall be read before commissioning the equipment and it shall be provided to all staff involved 

in transport, installation, operation, maintenance and repair.

The user manual may not be used for the purposes of competition without the written consent of E+E 

Elektronik® and may not be forwarded to third parties. Copies may be made for internal purposes. All 

information, technical data and diagrams included in these instructions are based on the information 

available at the time of writing.

1.1  Explanation of Symbols

This symbol indicates safety information.

It is essential that all safety information is strictly observed. Failure to comply with this information can 

lead to personal injuries or damage to property. E+E Elektronik® assumes no liability if this happens.

This symbol indicates instructions.

The instructions shall be observed in order to reach optimal performance of the device.

1.2  Safety Instructions

1.2.1  General Safety Instructions

•  Avoid any unnecessary mechanical stress and inappropriate use.

•  When replacing the filter cap make sure not to touch the sensing elements.

•  For sensor cleaning and filter cap replacement please see “Cleaning instructions” at www.epluse.com.

•  Installation, electrical connection, maintenance and commissioning shall be performed by  

qualified personnel only.

1.2.2  Mounting, Start-up and Operation

The device has been produced under state of the art manufacturing conditions, has been thoroughly 

tested and has left the factory fulfilling all safety criteria.  

The manufacturer has taken all precautions to ensure safe operation of the device. The user must  

ensure that the device is set up and installed in a manner that does not have a negative effect on its 

safe use.

The user is responsible for observing all applicable safety guidelines, local and international, with 

respect to safe installation and operation on the device. This user manual contains information and 

warnings that must be observed by the user in order to ensure safe operation.

•  Mounting, start-up, operation and maintenance of the device may be performed by qualified staff only. 

Such staff must be authorized by the plant operator to carry out the mentioned activities.

•  The qualified staff must have read and understood this user manual and must follow the instructions 

contained within.

•  All process and electrical connections shall be thoroughly checked by authorized staff before putting 

the system into operation. 

•  Do not install or start-up a device supposed to be faulty. Make sure that such devices are not 

accidentally used by marking them clearly as faulty.

•  A faulty device may only be investigated and possibly repaired by qualified, trained and authorized 

staff. If the fault cannot be fixed, the device shall be removed from the system. 

•  Service operations other than described in this user manual may only be performed by the 

manufacturer. 

Summary of Contents for EE1900

Page 1: ...BA_EE1900 v1 1 Modification rights reserved User Manual EE1900 HUMIDITY MODULE FOR CLIMATE CHAMBERS...

Page 2: ...equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmf...

Page 3: ...al 5 2 1 1 Sensing Probes 6 2 1 2 Filter Caps 6 2 2 Dimensions 6 2 3 Installation 6 2 3 1 Electronics Board 6 2 3 2 Sensing Probe 6 3 Electrical Connection 7 4 Setup and Configuration 8 4 1 Selection...

Page 4: ...commissioning shall be performed by qualified personnel only 1 2 2 Mounting Start up and Operation The device has been produced under state of the art manufacturing conditions has been thoroughly test...

Page 5: ...E E Elektronik are developed and manufactured observing of all relevant requirements with respect to environment protection Please observe local regulations for the device disposal For disposal the i...

Page 6: ...47 Probe length see ordering guide Cable length see ordering guide Filter length see table below 3 5 0 14 3 5 0 14 Fig 1 Dimensions of EE1900 2 3 Installation ESD handling regulations must be strictly...

Page 7: ...tor If the probe is installed into a partition wall the probe s backend shall be isolated thermally 3 Electrical Connection Supply Fig 2 Power supply 15 35 V DC 17 29 V AC Connection supply and output...

Page 8: ...RH and error indication according NAMUR see chapter 4 3 is disabled After switching the output between voltage and current with the slide switch the scaling of the output can be set using the E E Pro...

Page 9: ...manually by pressing the Sensor Recovery button No 6 Fig 3 for min 3 seconds or automatically by applying a voltage of 5 30 V DC to the potential free input No 3 Heat IN Fig 3 for at least 3 seconds A...

Page 10: ...overy The ARC mode is indicated by the closed contact at the optocoupler output No 3 Status Fig 3 and by the red LED flashing very quickly The optocoupler output thus indicates wether the data on the...

Page 11: ...guration PC HA011017 EE1900 The adjustment shall be performed for the RH output against an appropriate RH reference See Calibration Kit User Guide at www epluse com ee1900 7 Self Diagnosis and Error M...

Page 12: ...RH Dew point Td Working range 20 80 C 4 176 F Accuracy 2 C 3 6 F for Tambient Td 20 C 36 F General Response time RH t10 90 at 20 C 68 F typ 15 s with stainless steel grid filter2 Output signal 0 1 5...

Page 13: ...lin 69130 Ecully Tel 33 4 74 72 35 82 E mail info epluse fr E E Elektronik Germany Sch ne Aussicht 8 C 61348 Bad Homburg Tel 49 6172 13881 0 E mail info epluse de E E Elektronik Italy Via Alghero 17 1...

Reviews: