INSTALLATION INSTRUCTIONS

E-MT5, E-MT6, AND E-MT7 SERIES

Document

Date

Drawing/Page

DCR#

CI308X10R1
JAD

10-162

08/02/10

w w w.  e - c o n o l i g h t . c o m

8 8 8 . 2 4 3 . 9 4 4 5

FA X :  2 6 2 . 5 0 4 . 5 4 0 9

1. Turn power supply off.
2. Connect the black fixture lead (120V) to the HOT (usually black)

supply lead.

3. Connect the white fixture lead to the white supply lead

(COMMON).

4. Connect ground as appropriate. 

(NOTE: This fixture will have

either a “Green Ground lug” or a ground wire for grounding
   the  fixture.)

5. Cap and insulate all unused leads.
6. Be sure any unused wiring entrances are closed with closure

plugs provided.

INCANDESCENT FIXTURES

WIRING

1. Turn power supply off.
2. Connect the appropriate ballast voltage lead (120V or 277V) to

the HOT (usually black) supply lead.

3. Connect the ballast “Common” lead (usually white) to the

incoming “Common” lead (usually white).

4. Connect ground as appropriate. 

(NOTE: This fixture will have

either a “Green Ground lug” or a ground wire for grounding
the fixture.)

5. Cap and insulate all unused leads.
6. Be sure any unused wiring entrances are closed with closure

plugs provided.

HID FIXTURES

1. Turn power supply off.
2. Connect the black fixture lead to the HOT (usually black) supply

lead.

3. Connect the white fixture lead to the white supply lead

(COMMON).

4. Connect ground as appropriate. 

(NOTE: This fixture will have

either a “Green Ground lug” or a ground wire for grounding
the fixture.)

5. Cap and insulate all unused leads.
6. Be sure any unused wiring entrances are closed with closure

plugs provided.