background image

INTRODUCTION 

E.C.A. Proteus Plus Blue 24  kW  hermetic  combi boilers have been designed for efficient,  safe and 

comfortable  central  heating  and  domestic  hot  water  requirement.  Proteus  Plus  Blue  24  kW 

hermetic  combi boilers  have  the  facility  to be  operated  with  natural  gas  or  LPG as per the  fuel 

preference.

in this guide, you will find the assembly and usage information of E.C.A. Proteus Plus Blue hermetic 

combi  boilers  which  can  operate  with  natural  gas  or  LPG  as  per  fuel  preference.  Detailed 

explanations regarding technical features of the device, selection of the point of assembly, making 

the  connections  (water,  gas,  flue  and  electric),  gas  transformation,  maintenance  information, 

determination  of  possible  malfunctions  and  troubleshooting  have  been  provided  in  the  guide. 

Please carefully read the guide in order to benefit from ali the features of your device and to use it 

for a long term without any problems. 

Keep all the documents provided by your device in order to refer when required. 

WARRANTV AND SERViCE 

• AII repairs and annual maintenances should be performed by E.C.A. authorized services. Your device

has 3 years' E.C.A. service warranty against all kinds of malfunctions that may arise from material 

and workmanship provided that it is conformed to instructions and warnings being specified in the

assembly and usage guide.

• For the guarantee to be valid, you have to have the date of purchase recorded on the warranty

certificate provided by the guide and approved by the place from where you buy the device.

• This E.C.A.  product doesn't  require  repair  under  normal conditions of use. But in case you need

help on any issue, EMAR -the after sales customer services of E.C.A. being available in the whole

country- is always at your service.

• The list covering the addresses of our authorized services has been provided additionally. 
• The lifetime determined and declared by Ministry of Customs and Trade for the combi boiler devices is 

lSyears. 

• it is in conformity with the EEEregulation.

SVMBOLS

The  following  symbols  have  been  placed  at  required  points  within  the  text  in  order  to  attract 

attention to important points relevant to usage and assembly of the device. The meanings of the 

symbols have been specified below. 

(i)) 

B

i

'

lg

i

CAUTION: 

Specifies that material or insignificant personal damage may 

arise. 

DANGER: 

Specifies that significant personal damage may arise. 

• Explanations covering the information that should be considered

by the user.

• lndicates the conditions which shouldn't be interfered by the user and

which are under the responsibility of authorized service.

Summary of Contents for Proteus Plus Blue 24 kW

Page 1: ... E C A Call Center 444 O 322 PROTEUS PLUS BLUE HERMETIC MONOTERMIC COMBI BOILER COMBI BOILER INSTALLATION AND USER S OPERATING INSTRUCTIONS ...

Page 2: ...30 ...

Page 3: ...hat may arise from material and workmanship provided that it is conformed to instructions and warnings being specified in the assembly and usage guide For the guarantee to be valid you have to have the date of purchase recorded on the warranty certificate provided by the guide and approved by the place from where you buy the device This E C A product doesn t require repair under normal conditions ...

Page 4: ...2 ...

Page 5: ... resistant to temperature and thermal stress it operated silent with its special design and it ensures an efficient and clean combustion as the result of homogenous distribution of gas in accordance with the burner a combustion chamber with perfect isolation enabling high efficiency and low gas emission with minimum heat loss has been designed Due to these features of the burner and combustion cha...

Page 6: ...95 IPx4D 6 Proteus Plus Blue Proteus Plus Blue 24 kW 8 2 9 2 25 6 23 3 C 12x C 32x C 42x C 52X G20 Natural Gas G30 31 LPG 2 67 0 96 2 0 ...

Page 7: ......

Page 8: ...Ch Connectin Pipes Wall Bracket Mounting Bracket Gas Inlet Pipes Upper Styrofoam DHW Connecting Pipes ...

Page 9: ......

Page 10: ...Min distancetothe roof Human area Vehicle area Out of human and vehicle area ...

Page 11: ......

Page 12: ...on pipe in respect of preventing condensation in the pipes the part of hermetic flue up remaining at the roof space should be isolated d e Figure 5 lssues to be Considered in Flue Connections After determining the location where the combi boiler will be assembled The locations of lock screws of wall hanger bracket and assembly bracket are marked by using the assembly template on the last page of t...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...Restrictor Fan PRP BLUE ...

Page 17: ......

Page 18: ......

Page 19: ...L1 L2 L3 L1 L2 ...

Page 20: ...bustion to the external environment through the second pipe The lengths ofwastegas andfreshairconnection pipes and numbersof bends to beusedhavebeenprovided in Table 6 Figure 17 Connection elements for twin flue connection Figure 16 1 Twin hermetic flue set Zl 80x80 mm Figure 16a 2 Extension 500 mm 1000 mm Zl 80x80 mm Figure 16b 3 Bend of 90 Zl 80x80 mm Figure 16c 4 Bend of 45 Zl 80x80 mm Figure 1...

Page 21: ......

Page 22: ...312 Figure 19a E C A Digital Room Thermostat Cordless Programmable CM727 7006902046 Figure 19c E C A On Off Cordless Room Thermostat 7006907522 E C A On Off Cable Room Thermostat 7006907519 Figure 19e 20 E C A Smart Combi Boiler Kit 7006907531 Figure 19b E C A D Digital Room Thermostat 7006902502 Figure 19d E C A Programmable Digital Room Thermostat CM707 7006901313 Cordless 7006901501 Figure 19f ...

Page 23: ... consumption lf you will leave your device in operating state at late hours keeping the water temperature of central heating circuit low will enable saving Of you feel that the room temperature is high the radiator valves should be cut down instead of opening the windows START UPAND USAGE Final Controls and Operations Required to be Performed Before Start Up Bilgi As the result of determining the ...

Page 24: ......

Page 25: ... to OFF Reset position and turn to summer or winter position after waiting for 5 seconds lf the malfunction is continuing repeat this operation for a few times lf the malfunction is stili continuing despite resetting consult to the closest E C A service 2 Central Heating Water Temperature Adjusting Buttan While the position selection button is in winter f position you can select a comfort temperat...

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ...Malfunction Warning Led Error Maltunction Codes ...

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ...32 ...

Page 35: ......

Reviews: